Thermo Scientific Thermoflex 900 Recirculating Chiller
The Thermo Scientific Thermoflex 900 Recirculating Chiller is an air-cooled
unit that uses ambient-temperature room air to remove heat through its condenser.
This chiller offers powerful cooling abilities, a large temperature range, and
sophisticated controller technology. The Thermoflex 900 offers up to 10%
greater cooling capacity than comparable units. With a highly reliable
recirculation system and integrated air and fluid filters, this recirculating
chiller has a low risk of leaks and low lifetime maintenance cost. Features of
the Thermoflex 900 include auto refill, anti-drainback, DI resistivity internal,
pressure relief, flow control, and pressure/flow control. This unit is easy to use with intuitive interface and air and water filters that are changeable while unit is in operation.
Applications include analytical instrumentation, laser,
medical equipment, packaging, research, and university use.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Thermo Scientific Thermoflex 900 Recirculating Chiller includes:
- > Turbine Pump
- > Recirculating Chiller Calibration and Preventative Maintenance Report
- > Operator's Guide
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Thermoflex 900 Recirculating Chiller Specifications
|
Standard Chiller Process Fluid Temperature/Setpoint Range |
5 C to 40 C |
|
Ambient Temperature Range |
10 C to 40 C |
|
Temperature Stability |
0.1 C |
|
Cooling Capacity at 20 C |
900 W (3074 BTU) |
|
Refrigerant |
R134A |
|
Reservoir Volume |
1.9 Gallons (7.2 Liters) |
|
Foot print or Dimensions (H x W x D) |
27.3 x 14.2 x 24.6 in (69.2 x 36 x 62.4 cm) |
|
Weight with Turbine Pump |
130.5 lbs (59.2 kg) |
|
Voltage Requirement |
115V/60Hz |
|
Flow Rate- Turbine Pump |
13.3 L/min |
- Inspect display for dimming or dead pixels and replace as necessary to maintain clear visual feedback
- Verify functionality of all buttons and input devices, ensuring reliable and responsive control
- Check that all external hosing connections are secure and properly installed to prevent leakage
- Test unit flow rate on a closed-loop system to confirm consistent fluid dynamics
- Examine all external surfaces for leaks, confirming a sealed and contained system
- Inspect internal components for any signs of leaks to ensure system integrity
- Verify power supply output for accurate voltage delivery per operational specifications
- Inspect all internal wiring, checking for any frays, tears, or compromised insulation
- Replace internal filters to maintain optimal fluid purity and system performance
- Confirm that the fan operates at proper speeds to provide effective cooling
- Verify compressor functionality for consistent performance and cooling efficiency
- Test cooling capacity, confirming it meets performance specifications at 20°C
- Measure water pump output to confirm correct PSI for stable fluid flow
- Determine the lowest achievable temperature, verifying against manufacturer standards
- Ensure cosmetic condition meets standards with no damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Recirculating Chiller
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Inspect display for dimming or dead pixels, replace if necessary | Completed | |
| Verify functionality of all buttons and input devices | Completed | |
| Ensure external hosing connections are secure | Completed | |
| Test flow rate on closed-loop system | Completed | |
| Inspect for external leaks | Completed | |
| Inspect for internal leaks | Completed | |
| Verify power supply output voltage | Completed | |
| Inspect internal wiring for frays or tears | Completed | |
| Replace internal filters | Completed | |
| Confirm fan functionality | Completed | |
| Verify compressor functionality | Completed | |
| Test cooling capacity at 20°C | Completed | |
| Confirm water pump PSI output | Completed | |
| Determine lowest achievable temperature | Completed | |
| Ensure cosmetic condition meets standards | Completed |



Click Here to View the Technical Specs for the Thermoflex 900