Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V
Temperature Range
5 to 40 °C
Cooling Capacity
1400W
Temperature Stability
0.1°C
- Designed to handle the most demanding applications, ensuring consistent cooling.
- Features a meticulously engineered plumbing design that minimizes the risk of leaks.
- Offers ease of use, making it accessible for various skill levels.
- Allow for easy monitoring of fluid levels, ensuring optimal operation.
- Perfectly suited for a wide variety of research applications.
The Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V with turbine pump
is a reliable, easy-to-use, robust chiller capable of handling the most demanding applications. This chiller's recirculation system utilizes an impeccable plumbing design that both improves performance and eliminates chances of leaking. The Thermoflex 1400's mechanical parts are kept intact due to integrated air and fluid filters, lowering the potential lifetime maintenance cost. Simple push-button operation, changeable during use air and water filters, and visual fluid indicators make the Thermoflex 1400 easy to use, while also providing an improved cooling capacity.
Recommended applications include pharmaceutical, biotech, industrial, university, aerospace, medical, analytical, research, and chemical use.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
(This unit is only available in a 230V configuration).
The Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V includes:
- > Turbine Pump
- > Recirculating Chiller Calibration and Preventative Maintenance Report
- > Operator's Manual
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V Specifications
|
Temperature Range |
5 to 40 °C |
|
Cooling capacity |
1400W |
|
Set point temperature range |
5 to 40 °C |
|
Temperature Stability |
0.1°C |
|
Set point cooling capacity |
1400W (4781 BTU) |
|
Reservoir Volume |
7.2 liters |
|
Dimensions |
27.3 x 14.2 x 24.6 inches |
|
Turbine Pump |
Up to 2.5 gpm at 60 psig (9.5 lpm at 4.1 bar) (50Hz) Up to 3.5 gpm at 60 psig (13.3 lpm at 4.1 bar) (60Hz) |
|
Refrigerant |
R134A |
|
Power |
230V |
- Inspect display for dimming or dead pixels and replace as necessary to maintain clear visual feedback
- Verify functionality of all buttons and input devices, ensuring reliable and responsive control
- Check that all external hosing connections are secure and properly installed to prevent leakage
- Test unit flow rate on a closed-loop system to confirm consistent fluid dynamics
- Examine all external surfaces for leaks, confirming a sealed and contained system
- Inspect internal components for any signs of leaks to ensure system integrity
- Verify power supply output for accurate voltage delivery per operational specifications
- Inspect all internal wiring, checking for any frays, tears, or compromised insulation
- Replace internal filters to maintain optimal fluid purity and system performance
- Confirm that the fan operates at proper speeds to provide effective cooling
- Verify compressor functionality for consistent performance and cooling efficiency
- Test cooling capacity, confirming it meets performance specifications at 20°C
- Measure water pump output to confirm correct PSI for stable fluid flow
- Determine the lowest achievable temperature, verifying against manufacturer standards
- Ensure cosmetic condition meets standards with no damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Recirculating Chiller
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Inspect display for dimming or dead pixels, replace if necessary | Completed | |
| Verify functionality of all buttons and input devices | Completed | |
| Ensure external hosing connections are secure | Completed | |
| Test flow rate on closed-loop system | Completed | |
| Inspect for external leaks | Completed | |
| Inspect for internal leaks | Completed | |
| Verify power supply output voltage | Completed | |
| Inspect internal wiring for frays or tears | Completed | |
| Replace internal filters | Completed | |
| Confirm fan functionality | Completed | |
| Verify compressor functionality | Completed | |
| Test cooling capacity at 20°C | Completed | |
| Confirm water pump PSI output | Completed | |
| Determine lowest achievable temperature | Completed | |
| Ensure cosmetic condition meets standards | Completed |
Tests Performed on the Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V
- Cooling capacity test is performed at 20°C to confirm chiller functionality
- Flow rate is tested to verify pump is meeting manufacturer specifications
- Chiller is temperature cycled numerous times to ensure longevity of instrument
- Low temperature test is performed to ensure chiller is functioning within temperature range
Preventative Maintenance Performed on the Thermo Scientific Thermoflex 1400 Recirculating Chiller, 230V
- Pump is Inspected for Faults and Signs of Disrepair
- Motor is Inspected for Shorts and Corroded Wiring
- Plumbing is Inspected for Leaks and Corrosion
- Filters are Cleaned and Replaced if Needed
- Tank is Inspected for Leaks and Cleaned
- Internal Circuitry is Inspected for Faulty/Shorted Components and Replaced Accordingly
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Pump is Lubricated as Needed


Click Here to View the Technical Specs for the Thermoflex 1400