Thermo Scientific Haake SC100 Heated Immersion Circulator
The Thermo Scientific Haake SC100 Heated Immersion Circulator is a high-performance tool designed for use with both refrigerated and heated baths, with the capability to pump to external systems. This model is tailored for precision and ease of use, featuring a digital display and touch pad that simplifies operation. It supports five programmable setpoint temperatures, ensuring versatility for various applications. The SC100 is equipped with both acoustic and optical alarms for enhanced operational safety and is specifically designed to work with water or glycol-water mixtures. It offers a temperature range from Ambient +13°C to 100°C, maintaining a temperature stability of ± 0.02°C. With a 1200W heater capacity, it accommodates immersion depths from 3 to 5.7 inches (75 to 145 cm), providing flexibility for different bath sizes. The circulator achieves a maximum flow rate of 17 liters per minute (4.5 gallons per minute) and includes two pump speed steps to adjust flow rate as needed. Its maximum pressure capability is 300 mbar (4.35 psi), highlighting its efficient fluid management for a wide range of laboratory applications.
All of our equipment will be fully tested to perform at factory specifications before being shipped.
The Thermo Scientific Haake SC100 Heated Immersion Circulator includes:
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific Haake SC100 Heated Immersion Circulator Specifications
| Temperature Range | Ambient +13°C to 100°C |
| Temperature Stability | ± 0.02°C |
| Heater Capacity | 1200W |
| Immersion Depth | 3 to 5.7 in. (75 to 145 cm) |
| Maximum Flow Rate | 17L/min (4.5 gpm) |
| Maximum Pressure | 300 mbar (4.35 psi) |
| Pump Speed Steps | 2 |
| Dimensions (H x W x D) | 13.2 x 5.4 x 7.8 in. (33.6 x 13.8 x 19.9 cm) |
| Weight | 7.3 lb. (3.3 kg) |
| Electrical Requirements | 115V, 60Hz, 1 Ph |
- Inspect display for dimming or dead pixels and replace as necessary to maintain clear visual feedback
- Verify functionality of all buttons and input devices, ensuring reliable and responsive control
- Check that all external hosing connections are secure and properly installed to prevent leakage
- Test unit flow rate on a closed-loop system to confirm consistent fluid dynamics
- Examine all external surfaces for leaks, confirming a sealed and contained system
- Inspect internal components for any signs of leaks to ensure system integrity
- Verify power supply output for accurate voltage delivery per operational specifications
- Inspect all internal wiring, checking for any frays, tears, or compromised insulation
- Replace internal filters to maintain optimal fluid purity and system performance
- Confirm that the fan operates at proper speeds to provide effective cooling
- Verify compressor functionality for consistent performance and cooling efficiency
- Test cooling capacity, confirming it meets performance specifications at 20°C
- Measure water pump output to confirm correct PSI for stable fluid flow
- Determine the lowest achievable temperature, verifying against manufacturer standards
- Ensure cosmetic condition meets standards with no damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Recirculating Chiller
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Inspect display for dimming or dead pixels, replace if necessary | Completed | |
| Verify functionality of all buttons and input devices | Completed | |
| Ensure external hosing connections are secure | Completed | |
| Test flow rate on closed-loop system | Completed | |
| Inspect for external leaks | Completed | |
| Inspect for internal leaks | Completed | |
| Verify power supply output voltage | Completed | |
| Inspect internal wiring for frays or tears | Completed | |
| Replace internal filters | Completed | |
| Confirm fan functionality | Completed | |
| Verify compressor functionality | Completed | |
| Test cooling capacity at 20°C | Completed | |
| Confirm water pump PSI output | Completed | |
| Determine lowest achievable temperature | Completed | |
| Ensure cosmetic condition meets standards | Completed |



Click Here to View the Technical Specs for the Thermo Scientific Haake SC100 Heated Immersion Circulator