Shimadzu TXC323L Analytical Balance
The Shimadzu TXC323L Analytical Balance is capable of performing delicate jobs with its durable, high-performance aluminum alloy mass sensor. Features include power saving function, fast and flexible calibration, expanded piece counting function, single-touch weighing unit and function change, illuminated display, etc. Comparator function compares samples to target values or pass/fail criteria and clearly indicates the results.
This balance is in great condition.
> Power Cord
> Operator's Manual
> Full 180 Day Parts and Labor Warranty
Shimadzu TXC323L Analytical Balance Specifications
|
Max. Capacity |
620 ct (124 g) |
|
Readability |
0.001 ct (0.0002 g) |
|
Repeatability (sd) |
? 0.0002 g |
|
Linearity |
0.0004 g |
|
Calibration Type |
Manual |
|
RS-232 |
Yes |
|
Stabilization Time |
3 Seconds |
|
Electrical Requirements |
115V, 50/60Hz |
| Weighing Pan Size | 80 mm |
| Dimensions (W x D x H) | 206 x 291 x 241 mm |
- Verify power supply output for precise voltage delivery in accordance with equipment specifications
- Assess full functionality of display and control buttons, replacing any defective or deteriorating components as necessary
- Confirm balance is properly leveled to ensure measurement accuracy and stability
- Examine windscreen glass for cracks or chips, replacing if structural integrity is compromised
- Inspect all internal wiring and electrical connections for secure attachment and check for any loose connections or damaged connectors
- Check power cord integrity, ensuring there are no frays, cuts, or damage affecting function or safety
- Execute internal or external calibration to confirm accuracy of weighing measurements
- Review cosmetic condition, confirming no visible damage or wear that affects functionality
- Verify successful taring of the weighing pan to zero out prior measurements accurately
- Ensure RS232/printer communication functions correctly, validating connection and data transmission (if applicable)
Technician Inspection and Recertification Checklist: Balances
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Verify power supply output voltage | Completed | |
| Assess display and control button functionality, replacing faulty components | Completed | |
| Confirm balance leveling for measurement accuracy | Completed | |
| Inspect windscreen glass for cracks, replace if necessary | Completed | |
| Check internal wiring and electrical connections for security | Completed | |
| Inspect power cord for frays or damage | Completed | |
| Execute internal/external calibration for measurement accuracy | Completed | |
| Review cosmetic condition for visible damage | Completed | |
| Verify weighing pan tares successfully | Completed | |
| Ensure RS232/printer communication is functional (if applicable) | Completed |
Shimadzu TXC323L Analytical Balance Manual
Click Here to View the Technical Specs for the Shimadzu TXC323L Analytical Balance



Click Here to View the Technical Specs for the Shimadzu TXC323L Analytical Balance