Cole Parmer SH-200D-R-L Orbital Shaker
Speed Range
25 to 250 RPM
Reciprocating Amplitude
0.79 in. (2.0 cm)
Timer
1 to 999 minutes or continuous operation
- Digital speed control provides consistent, repeatable operation
- Microprocessor-controlled operation accurately maintains selected settings during extended runs
- Built-in digital timer supports runs from 1 to 999 minutes
- Continuous operation mode available for longer laboratory workflows
- Audible alert signals completion of timed runs
- Quiet shaking mechanism designed for continuous laboratory use
- Accommodates a variety of flasks, bottles, beakers, and other laboratory vessels
- Suitable for use in compatible environmental chambers and CO₂ incubators
- Well suited for extractions, mixing, and routine sample preparation applications
The Cole Parmer SH-200D-R-L Orbital Shaker, Cat. #51901-03 is a durable laboratory shaker designed for reliable continuous operation across extraction, mixing, and general sample preparation applications. The unit provides a linear reciprocating shaking motion with a 20 mm amplitude and variable speed range from 25 to 250 RPM. Microprocessor-controlled digital speed adjustment helps maintain consistent shaking performance throughout extended runs, while its quiet operation makes the SH-200D-R-L well suited for routine laboratory environments.
Designed for versatile laboratory use, the SH-200D-R-L can accommodate a variety of flasks, bottles, beakers, and other common laboratory vessels. A built-in digital timer allows shaking periods from 1 to 999 minutes, with an audible alert upon completion, while continuous operation is available for longer workflows. The shaker supports loads up to 10 kg and can also be operated within compatible environmental chambers and CO₂ incubators.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Cole Parmer SH-200D-R-L Orbital Shaker includes:
- Platform
- Power Cord
- Operator's Manual
- Full 180 Day Parts and Labor Warranty
Cole Parmer SH-200D-R-L Orbital Shaker Specifications
| Speed Range | 25 to 250 RPM |
| Reciprocating Amplitude | 0.79 in. (2.0 cm) |
| Maximum Load | 22 lb. (10 kg) |
| Operating Temperature Range | 39°F to 104°F (4°C to 40°C) |
| Maximum Permissible Humidity | 80% |
| Timer Range | 1 to 999 minutes or continuous operation |
| Speed Control | Digital, microprocessor controlled |
| Dimensions (W x D x H) | 14.2 x 16.5 x 10.6 in. (36 x 42 x 27 cm) |
| Weight | 24.3 lb. (11 kg) |
| Electrical Requirements | 120V, 60Hz, 30W |
- Validate that the power supply and PCB deliver stable, correct voltage outputs across all necessary connections, ensuring reliable operation
- Thoroughly inspect the display for any dim, flickering, or dead pixels; replace affected elements to maintain full readability and operational clarity
- Test the full range of button functionality, confirming responsive, accurate input recognition across all settings
- Conduct a detailed inspection of bearings and bearing housing, identifying any worn or damaged bearings, and replace as needed to prevent operational disruption
- Examine the drive belt for signs of cracking, fraying, or material breakdown; replace as required to ensure sustained performance
- Measure and adjust motor drive belt tension to optimal specifications, securing reliable and efficient power transmission
- Verify accuracy of the onboard timer, confirming proper functionality and replacing if it deviates from expected performance
- Calibrate shaker rotation speed with a NIST-traceable tachometer, validating precision within specified operational limits
- Run the shaker continuously for an 8-12 hour testing period, closely observing the shaking platform for smooth, consistent motion, while monitoring for any error indicators such as knocking, skipping, or unusual vibrations
- Perform a comprehensive cosmetic inspection to confirm the device’s exterior meets aesthetic and quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Shakers
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Validate stable, correct voltage outputs from power supply and PCB | Completed | |
| Inspect display for dim, flickering, or dead pixels; replace as needed | Completed | |
| Test button functionality for responsiveness and accuracy across all settings | Completed | |
| Inspect bearings and housing for wear; replace as needed to prevent disruption | Completed | |
| Examine drive belt for cracking, fraying, or material breakdown; replace as required | Completed | |
| Measure and adjust motor drive belt tension to optimal specifications | Completed | |
| Verify onboard timer accuracy; replace if it deviates from expected performance | Completed | |
| Calibrate shaker rotation speed using a NIST-traceable tachometer | Completed | |
| Run 8-12 hour continuous test; observe platform for smooth, consistent motion | Completed | |
| Perform comprehensive cosmetic inspection for quality standards compliance | Completed |




Click Here to View the Technical Specs for the Cole Parmer SH-200D-R-L Orbital Shaker