Agilent 1290 Infinity II HPLC System w/ DAD
Wavelength Range (DAD)
190 to 640 nm
Flow Rate Range
>0.001 to 5.0 mL/min, in 0.001 mL/min increments
Pressure Range
Up to 130 MPa (1300 bar) at 0 to 2 mL/min
- Complete four-module UHPLC stack rated to 1300 bar for conventional HPLC and ultra-high-pressure methods
- Flexible Pump with low-pressure quaternary gradient formation from an integrated four-solvent valve
- Dual-piston servo-controlled hydraulics with active damping for pressure pulsation under 1%
- Intelligent System Emulation Technology (ISET) for transferring legacy methods with retention times intact
- Flow-through needle Multisampler with 0.1 to 20 µL injections and carryover below 30 ppm
- Vial and microtiter plate handling in configurable single-, double-, and triple-height drawers
- Injector programming for multi-draw, mixing, dilution, and stacked injections
- Dual-zone Peltier column thermostat spanning 4°C to 110°C with ±0.05°C stability
- Column compartment holds up to eight 100 mm or four 300 mm columns with individual heat exchangers
- 1024-element diode array detector with eight simultaneous signals and 240 Hz data rate
- Programmable 1, 2, 4, and 8 nm slit widths to balance sensitivity and spectral resolution
- RFID-tagged flow cells and lamps with Early Maintenance Feedback across every module
- Shared leak-plane design with automatic pump shutdown on any internal leak
- Ships with a Windows 11 workstation for instrument control and data acquisition
The Agilent 1290 Infinity II HPLC System with Diode Array Detector (DAD) combines the G7104A Flexible Pump, G7167B Multisampler, G7116B Multicolumn Thermostat, and G7117B DAD into one UHPLC stack rated to 1300 bar, capable of running both conventional HPLC and ultra-high-pressure methods. Intelligent System Emulation Technology (ISET) allows methods from other LC systems to be transferred with retention times and resolution intact. The Flexible Pump delivers 0.001 to 5 mL/min from a dual-piston, servo-controlled design with active damping, pairing low-pressure quaternary gradient formation with an integrated four-channel degasser, automatic purge valve, and active seal wash.
The Multisampler’s flow-through needle limits carryover and sample discrimination while accepting vials and microtiter plates in configurable drawers. Injections from 0.1 to 20 µL are delivered at full system pressure, with programming for multi-draw, mixing, dilution, and stacked injections. The Multicolumn Thermostat provides two independent Peltier zones from 4 °C to 110 °C (as low as 20 °C below ambient) with ±0.05 °C stability, holding up to eight 100 mm or four 300 mm columns with solvent preheating and still-air operation to minimize band broadening.
The G7117B Diode Array Detector pairs a 1024-element array with a 10 mm Max-Light cartridge flow cell, whose optofluidic waveguides pass nearly 100% of available light for a quiet, stable baseline. It spans 190 to 640 nm, records up to eight signals and full spectra at rates to 240 Hz, and offers programmable slit widths of 1, 2, 4, and 8 nm. The self-aligning, RFID-tagged cartridge cell seats without tools and carries its own usage record.
Across the stack, a shared leak-plane design stops the pump on any internal leak, and Early Maintenance Feedback tracks seal wear, pumped volume, injections, and lamp hours against user-set limits. Suited to pharmaceutical QC, method development, and high-throughput analysis, the Agilent 1290 Infinity II HPLC System with DAD delivers the pressure range, injection flexibility, and detection sensitivity modern separations require.
The Agilent 1290 Infinity II HPLC System with DAD is operated through Agilent OpenLab CDS or ChemStation software for instrument control, data acquisition, analysis, and automation.
This Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
The Agilent 1290 Infinity II HPLC System w/ DAD includes:
- G7104A Flexible Pump
- G7117B DAD Detector
- G7116B Multi Column Thermostat
- G7167B Multisampler
- Windows 11 Professional 64-Bit Data Station with Flatscreen Monitor
- ChemStation Version 4.3 Software Installed
- Can/Crossover Cables
- Agilent Lan Interface Card Built-In
- Solvent Tubing
- New Stainless Steel Capillaries
- 1/4" Wrench & Mobile Phase Priming Syringe
- Waste Tubing
- All Power Cords
- Agilent 4 Peak Test w/ Lab Advisor Diagnostics Report
- Full 180 Day Parts and Labor Warranty
Agilent 1290 Infinity II HPLC System w/ DAD Specifications
| Detection Type | 1024-element photodiode array |
| Light Source | Deuterium lamp |
| Wavelength Range | 190 to 640 nm |
| Number of Signals | 8 |
| Short Term Noise (ASTM) | < ± 3 x 10-6 AU (10 mm cell, included); < ± 0.6 x 10-6 AU/cm (60 mm cell), at 230/4 nm |
| Drift | < 0.5 x 10-3 AU/h at 230 nm |
| Linearity | > 2.0 AU (5%) at 265 nm |
| Wavelength Accuracy | ± 1 nm, self-calibration with deuterium lines |
| Wavelength Precision | < ± 0.1 nm |
| Wavelength Bunching | 2 to 400 nm, programmable in 1 nm steps |
| Slit Width | Programmable: 1, 2, 4, 8 nm |
| Diode Width | ~ 0.5 nm |
| Maximum Sampling Rate | 240 Hz (signals and spectra) |
| Flow Cell | Standard 10 mm Max-Light cartridge cell, σV = 1.0 µL; 60 bar (870 PSI) maximum pressure |
| Dimensions (H x W x D) | 5.5 x 15.6 x 17.2 in. (14.0 x 39.6 x 43.6 cm) |
| Weight | 25.4 lb. (11.5 kg) |
| Electrical Requirements | 100–240V, 50/60Hz |
| Hydraulic System | Dual pistons in series with servo-controlled variable stroke design and active damping |
| Settable Flow Range | 0.001 to 5.0 mL/min, in 0.001 mL/min increments |
| Flow Precision | ≤ 0.07% RSD or 0.01 min SD, whichever is greater |
| Flow Accuracy | ± 1% or ± 10 µL/min, whichever is greater |
| Pressure Operating Range | Up to 130 MPa (1300 bar) at 0 to 2 mL/min; 80 MPa (800 bar) at 5 mL/min |
| Pressure Pulsation | < 1% amplitude or < 0.5 MPa (5 bar), whichever is greater |
| Compressibility Compensation | Automatic |
| Gradient Formation | Low-pressure quaternary mixing |
| Delay Volume | As low as 350 µL |
| Composition Range | Settable range: 0 to 100%; Recommended range: 1 to 99% or 5 µL/min |
| Composition Precision | < 0.15% RSD or 0.02 min SD, whichever is greater |
| Composition Accuracy | ± 0.4% absolute (1 to 99% B) |
| Number of Solvents | 4, expandable to a maximum of 26 with optional external solvent selection valve |
| Solvent Selection Valve | Integrated 4-solvent gradient formation valve |
| Integrated Degassing Unit | 4 channels, 1.5 mL internal volume per channel |
| Automatic Purge Valve | Included; supports inline-filter backflush and automatic mixer change |
| Dimensions (H x W x D) | 7.1 x 15.6 x 17.2 in. (18.0 x 39.6 x 43.6 cm) |
| Weight | 35.5 lb. (16.1 kg) |
| Electrical Requirements | 100–240V, 50/60Hz |
| Hydraulic System | Flow-through needle design for minimized sample carryover and discrimination |
| Injection Range | 0.1 to 20 µL |
| Injection Precision | < 0.15% RSD or SD < 10 nL |
| Injection Accuracy | 0.7% (10 µL, n=10) |
| Pressure Range | Up to 130 MPa (1300 bar) |
| Sample Viscosity Range | 0.2 to 5 cP |
| Sample Capacity (Configuration Dependent) | Up to 6,144 samples using microtiter plates or 432 standard 2 mL vials; configurable single-, double-, and triple-height drawers |
| Injection Cycle Time | As low as 10 seconds (single-needle configuration) |
| Carryover | < 0.003% (30 ppm) without Multiwash |
| Injection Programming | Multi-draw, mixing, stacked injection, and dilution |
| Dimensions (H x W x D) | 12.6 x 15.6 x 18.4 in. (32.0 x 39.6 x 46.8 cm) |
| Weight | 48.5 lb. (22 kg), without sample cooler |
| Electrical Requirements | 100–240V, 50/60Hz |
| Operating Principle | Dual independent Peltier-element temperature control with solvent preheating and still-air operation |
| Temperature Range | 4°C to 110°C (minimum 20°C below ambient) |
| Temperature Stability | ± 0.05°C |
| Temperature Accuracy | ± 0.5°C (with calibration) |
| Independent Temperature Zones | 2 in single device; up to 6 in clustered configuration |
| Column Capacity | Up to 8 columns of 100 mm length or 4 columns of 300 mm length, including Quick-Connect fittings or pre-columns |
| Heat-Up / Cool-Down Time | 5 min from ambient to 40°C; 10 min from 40°C to 20°C |
| Solvent Heat Exchangers | Individually quick-installable for each column; available in 1.0 µL (ultra-low dispersion), 1.6 µL (standard), and 3 µL (high-flow) volumes |
| Valve Options | Optional integrated valve drive and up to 2 external valve drives; supports 2-position/6-port, 2-position/10-port, 6-column, and 8-column selection valve heads (up to 1300 bar) |
| Dimensions (H x W x D) | 6.3 x 17.1 x 17.2 in. (16.0 x 43.5 x 43.6 cm) |
| Weight | 27.6 lb. (12.5 kg) |
| Electrical Requirements | 100–240V, 50/60Hz |
Computer Specifications |
|
| Processor | Intel Core i5-8500 CPU |
| RAM | 32.0 GB |
| Hard Drive | 500GB Internal SSD |
| Operating System | Windows 11 Professional, 64-bit |
- Verify uniformity of main and residential firmware across all components, updating as necessary to ensure compatibility
- Confirm successful communication between software and the HPLC system, validating data transfer integrity
- Check the degasser’s internal vacuum to confirm it reaches the specified vacuum level for optimal performance
- Replace inlet, outlet, purge valve, and pump seals in the system pump to maintain reliable operation
- Ensure system pump passes pressure and leak tests, confirming secure and efficient performance
- Replace all capillary tubing with new OEM stainless steel tubing for durability and precision
- Remove autosampler transport assembly, replace X and Y bearings, and thoroughly clean carrier rails to remove debris and contaminants
- Replace metering valve seal, autosampler needle, and needle seat for consistent sampling accuracy
- Test column compartment switching valve functionality and replace its seal if necessary
- Confirm column compartment passes thermostat test to maintain precise temperature control
- Remove and clean internal detector optics for clear and accurate signal detection
- Replace UV and Vis detector lamps to ensure optimal light source stability and performance
- Verify flow cell absorbance meets manufacturer’s specifications for accurate measurement
- Confirm system response to isocratic test sample, ensuring stable and reproducible results
Technician Inspection and Recertification Checklist: HPLC Systems
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Verify firmware uniformity and update as necessary | Completed | |
| Confirm software communication with HPLC system | Completed | |
| Check degasser vacuum level for optimal performance | Completed | |
| Replace inlet, outlet, purge valve, and pump seals | Completed | |
| Ensure pump passes pressure and leak tests | Completed | |
| Replace all capillary tubing with OEM stainless steel tubing | Completed | |
| Remove autosampler transport assembly, replace bearings, and clean rails | Completed | |
| Replace metering valve seal, autosampler needle, and needle seat | Completed | |
| Test column compartment switching valve and replace seal if needed | Completed | |
| Confirm thermostat test in column compartment | Completed | |
| Clean internal detector optics | Completed | |
| Replace UV and Vis detector lamps | Completed | |
| Verify flow cell absorbance meets manufacturer’s specifications | Completed | |
| Confirm system response to isocratic test sample | Completed |



Click Here to View the Technical Specs for the Agilent 1290 Infinity II HPLC System w/ DAD