Agilent 1100 HPLC G1367A Autosampler
Injection Range
0.1 – 100 µl in 0.1 µl increments
Precision
Typically < 0.5 % RSD of peak areas from 5 – 100 µl
Sample Capacity
2 × well-plates (MTP) + 10 × 2 ml vials
- Designed for high-throughput HPLC applications requiring fast injection cycles
- Typical injection cycle time under 30 seconds for efficient sample processing
- Extremely low carry-over—typically less than 0.01%—for reliable trace analysis
- Supports a sample viscosity range of 0.2 to 5 cP for versatile sample compatibility
- Advanced safety features including leak detection, safe leak handling, and low-voltage maintenance zones
- GLP-compliant with electronic maintenance tracking and error logging
- Multiple communication options including CAN, RS-232C, APG Remote, and optional contact closures

The Agilent 1100 G1367A Autosampler adds maximum flexibility and fast injection cycles to your Agilent HPLC system. Whenever high sample throughput and speed of analysis are points to consider, the G1367A is the autosampler to choose.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1100 HPLC G1367A Autosampler includes:
- Latest Available Firmware Version (Please inquire)
- Vial Tray (Please Inquire for Well Plate Tray)
- Lab Advisor Documentation
- Lan Cable / Power Cord
- Operator's Manual
- Full 180 Day Parts and Labor Warranty
Agilent 1100 HPLC G1367A Autosampler Specifications
|
GLP Features |
Early maintainece feedback (EMF), electronic records of maintainence and errors |
|
Communications |
Controller-area network (CAN). RS232C, APG remote standard, optional four external contact closures and BCD vial number output |
|
Safety Features |
Leak detection and safe leak handling, low voltages in maintence areas, error detection and display |
|
Injection Range |
0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required) |
|
Precision |
Typically < 0.5 % RSD of peak areas from 5 – 100 µl, Typically < 1 % RSD from 1 – 5 µl |
|
Sample Viscosity Range |
0.2 – 5 cp |
|
Sample Capacity |
2 × well-plates (MTP) + 10 × 2 ml vials [Not Included] |
|
Injection Cycle Time |
Typically < 30 s using following standard conditions: Default draw speed: 200 µl/min Default eject speed: 200 µl/min Injection volume: 5 µl |
|
Carry-Over |
Typically < 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: Water/Acetonitrile = 80/20 Flow rate: 1 ml/min Injection volume: 1 µl caffeine (1 mg/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port |
Agilent 1100 G1367A Manual
Click Here to View all the Technical Specs for the G1367A Autosampler