Agilent 1100 HPLC G1329A Autosampler
Injection Range
0.1 – 100 µl
Minimum Sample Volume
1 µl from 5 µl
Precision
< 0.5 % RSD of peak areas from 5 – 100 µl
- Ranges from 1 to 100 µl, offering flexibility for various sample sizes.
- Programmable operations allow precise control over sample injections.
- Early Maintenance Feedback provides electronic records of maintenance and errors for proactive equipment management.
- Leak Detection equipped with mechanisms for safe leak handling, enhancing safety.
- Error detection and display alerts users to any operational issues for timely troubleshooting.
- Designed to fit on almost any laboratory bench, maximizing space efficiency.

The Agilent 1100 HPLC G1329A Autosampler is a variable volume autosampler with a sample capacity of 100 samples. The G1329A's variable volume injections range from 1 to 100 µl and are programmable and temperature controlled. The temperature ranges from 4° to 40°C with a temperature accuracy of -1° to +5°C when in use with an ALS Thermostat module.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Agilent 1100 HPLC G1329A Autosampler includes:
- Latest Available Firmware Version (Please inquire)
- 100 Vial Tray
- Front Cover
- Lab Advisor Documentation
- Lan Cable / Power Cord
- Operator's Manual
- Full 180 Day Parts and Labor Warranty
Agilent 1100 HPLC G1329A Autosampler Specifications
|
GLP Features |
Early maintenance feedback (EMF), electronic records of maintenance and errors |
|
Communications |
Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output |
|
Safety Features |
Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display |
|
Injection Range |
0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required) |
|
Replicate Injections |
1 – 99 from one vial |
|
Precision |
Typically < 0.5 % RSD of peak areas from 5 – 100 µl Typically < 1 % RSD of peak areas from 1 – 5 µl |
|
Minimum Sample Volume |
1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial |
|
Carryover |
Typically < 0.1 %, < 0.05 % with external needle cleaning |
|
Sample Viscosity Range |
0.2 – 50 cp |
|
Replicate Injections Per Vial |
1 – 99 |
|
Sample Capacity |
100 × 2-ml vials in 1 tray 40 × 2-ml vials in ½ tray 15 × 6-ml vials in ½ tray (Agilent vials only) |
|
Injection Cycle Time |
Typically 50 s depending on draw speed and injection volume |



Click Here to View the Technical Specs for the G1329A