Out of Stock? We Recommend This Alternative
Thermo Accel 500 LT Recirculating Chiller 115V
- Temperature Range of -25°C to 80°C
- Maximum Flow Rate of 21 L/min
- Cooling Capacity of 500W at 20°C
- Full 180 Day Parts and Labor Warranty
Fisher Scientific Isotemp 500 LCSU Recirculating Chiller
The Fisher Scientific Isotemp 500 LC Recirculating Chiller is new. This chiller has a full range of heating and cooling from -10°C to +80°C with fast ramping time. The intuitive user interface allows users to choose between five temperature setpoints. With a small footprint and quiet operation, the Isotemp 500 LCSU is ideal for any lab environment.
Applications include chemical reaction control, separations, life science instrumentation, mass spectroscopy, molecular spectroscopy, atomic spectroscopy, surface science, materials characterization, laboratory automation, and general laboratory instrumentation.
This chiller is in new condition and is fully tested to perform at factory
specifications before being shipped.
The Fisher Scientific Isotemp 500 LCSU Recirculating Chiller includes:
- Power Cord
- Operator's Guide
- Full 180 Day Parts and Labor Warranty
Fisher Scientific Isotemp 500 LCSU Recirculating Chiller Specifications
|
Heating Capacity |
1000W |
|
Cooling Capacity |
500W |
|
Volume Reservoir |
2.8L |
|
Voltage, Hertz |
115V, 60Hz |
|
Dimensions (H x W x D) |
25 x 9 x 19 in. (63.5 x 22.8 x 48.2 cm) |
|
Temperature Stability |
±0.1°C |
|
Max Flow Rate |
21 lpm (5.5 gpm) |
|
Temperature Range |
-10°C to +80°C |
|
Weight |
29.93kg |
- Inspect display for dimming or dead pixels and replace as necessary to maintain clear visual feedback
- Verify functionality of all buttons and input devices, ensuring reliable and responsive control
- Check that all external hosing connections are secure and properly installed to prevent leakage
- Test unit flow rate on a closed-loop system to confirm consistent fluid dynamics
- Examine all external surfaces for leaks, confirming a sealed and contained system
- Inspect internal components for any signs of leaks to ensure system integrity
- Verify power supply output for accurate voltage delivery per operational specifications
- Inspect all internal wiring, checking for any frays, tears, or compromised insulation
- Replace internal filters to maintain optimal fluid purity and system performance
- Confirm that the fan operates at proper speeds to provide effective cooling
- Verify compressor functionality for consistent performance and cooling efficiency
- Test cooling capacity, confirming it meets performance specifications at 20°C
- Measure water pump output to confirm correct PSI for stable fluid flow
- Determine the lowest achievable temperature, verifying against manufacturer standards
- Ensure cosmetic condition meets standards with no damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Recirculating Chiller
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Inspect display for dimming or dead pixels, replace if necessary | Completed | |
| Verify functionality of all buttons and input devices | Completed | |
| Ensure external hosing connections are secure | Completed | |
| Test flow rate on closed-loop system | Completed | |
| Inspect for external leaks | Completed | |
| Inspect for internal leaks | Completed | |
| Verify power supply output voltage | Completed | |
| Inspect internal wiring for frays or tears | Completed | |
| Replace internal filters | Completed | |
| Confirm fan functionality | Completed | |
| Verify compressor functionality | Completed | |
| Test cooling capacity at 20°C | Completed | |
| Confirm water pump PSI output | Completed | |
| Determine lowest achievable temperature | Completed | |
| Ensure cosmetic condition meets standards | Completed |
Tests Performed on the Fisher Scientific Isotemp 500 LCSU Recirculating Chiller
- Cooling capacity test is performed at 20°C to confirm chiller functionality
- Flow rate is tested to verify pump is meeting manufacturer specifications
- Chiller is temperature cycled numerous times to ensure longevity of instrument
- Low temperature test is performed to ensure chiller is functioning within temperature range
Preventative Maintenance Performed on the Fisher Scientific Isotemp 500 LCSU Recirculating Chiller
- Pump is Inspected for Faults and Signs of Disrepair
- Motor is Inspected for Shorts and Corroded Wiring
- Plumbing is Inspected for Leaks and Corrosion
- Filters are Cleaned and Replaced if Needed
- Tank is Inspected for Leaks and Cleaned
- Internal Circuitry is Inspected for Faulty/Shorted Components and Replaced Accordingly
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Pump is Lubricated as Needed
Thermo Scientific Accel 500 LCSU Operator's Manual
Click Here to View all the Technical Specs for the Isotemp 500 LCSU



Click Here to View the Technical Specs for the Isotemp 500 LCSU