Amerex Gyromax 737 Incubator Shaker
The Amerex GYROMAX 737/737R stackable incubator shakers are versatile floor model units that are perfectly sized for handling high volume capacity bacteria and yeast cell cultures, while taking up a small footprint in the lab space. The 737R (refrigerated shaking incubator) and 737 (non-refrigerated shaking incubator) can each hold up to 6 x two-liter flasks and both can be stacked to minimize footprint. At 34" tall, the 737 will comfortably fit under most bench tops, while both units can accommodate a shelf for simultaneous non-shaking incubation.
All of our products are fully tested to perform at factory specifications before being shipped.
The Amerex Gyromax 737 Incubator Shaker includes:
- NIST Calibration and Preventative Maintenance Report
- Power Cord
- Full 180 Day Parts and Labor Warranty
Amerex Gyromax 737 Incubator Shaker Specifications
|
Temperature Range |
5° above ambient to 80°C |
|
Temperature Accuracy |
±0.1°C |
|
Temperature Uniformity |
±0.5°C |
|
Speed Range |
20 to 400 RPM |
|
Orbit |
1 in (25 mm) |
|
Chamber Dimension (H x W x D) |
24 x 20.5 x 18 in |
|
Overall Dimensions (H x W x D) |
34 x 33 x 24 in |
- Examine the chamber glass for cracks or chips, replacing it as needed to maintain structural integrity.
- Inspect door seals for signs of wear or damage, replacing them to ensure a tight seal.
- Check the display for brightness and clarity, replacing any dim or dead pixels to maintain optimal visibility.
- Test all buttons to confirm full functionality and consistent responsiveness.
- Replace all platform assembly bearings to ensure smooth and reliable motion.
- Inspect the drive belt for wear, replacing it if torn or cracked to maintain performance.
- Examine all wiring for frays, tears, or breakages, addressing any issues for electrical safety.
- Verify each PCB test point, replacing any malfunctioning components to ensure system reliability.
- Check drive belt tension to confirm correct alignment and function.
- Confirm the compressor’s operation, cleaning condenser filter and fins for efficient cooling.
- Calibrate internal temperature accuracy using an NIST-traceable temperature probe.
- Measure and calibrate platform RPMs with an NIST-traceable tachometer to ensure precision.
- Conduct a final cosmetic inspection to verify all surfaces meet appearance standards.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Examine chamber glass for cracks or chips, replace as needed | Completed | |
| Inspect door seals for wear, replace to ensure tight seal | Completed | |
| Check display brightness, replace dim or dead pixels | Completed | |
| Test all buttons for full functionality and responsiveness | Completed | |
| Replace platform assembly bearings for reliable motion | Completed | |
| Inspect drive belt for wear, replace if torn or cracked | Completed | |
| Examine wiring for frays or breakages, repair as needed | Completed | |
| Verify PCB test points, replace faulty components | Completed | |
| Check drive belt tension for proper alignment | Completed | |
| Confirm compressor functionality, clean filter and fins | Completed | |
| Calibrate internal temperature with NIST probe | Completed | |
| Calibrate platform RPM with NIST-traceable tachometer | Completed | |
| Conduct cosmetic inspection for appearance standards | Completed |
Click Here to View all the Technical Specs for the Gyromax 737


Click Here to View all the Technical Specs for the Gyromax 737