Arctiko ULUF 15 -86C Ultra Low Undercounter Freezer
Temperature Setting
-40°C / -86°C
Volume
0.3 cu. ft. (7L)
Cooling System
Single System / Static
- Single compressor technology that ensures easy maintenance, lower heat dissipation, and low energy consumption
- Newly developed noise reduction technology reduces noise level drastically for a more pleasant work environment
- Filter less construction prevents dust from blocking the airflow which reduces the unit’s ability to dissipate heat effectively, minimizing maintenance procedure
- Direct cooling features evaporator coils to cool each compartment directly for maximum uniformity and minimal recovery time
- A heated door frame prevents ice from building up around the gasket securing a stable and uniform temperature inside the freezer
- The user friendly G214 controller is standard and includes different alarms such as visual, acoustic, open door, and more
- An insulated inner door is featured for providing better recovery time after door openings and optimal temperature stability
- 100% HCFC & CFC free
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Arctiko ULUF 15 -86C Ultra Low Undercounter Freezer includes:
- Key for Door Lock
- Power Cord
- Operator's Manual
- Full 180 Day Parts and Labor Warranty
Arctiko ULUF 15 -86C Ultra Low Undercounter Freezer Specifications
| Temperature Setting | -40°C / -86°C |
| Volume | 0.3 cu. ft. (7L) |
| Cooling Technology | Single System / Static |
| Defrost Method | Manual |
| Refrigerant | EP88 |
| Controller Model | G214, 4.3" display with touch buttons |
| Probe Type | PT1000 |
| Alarm Styles | Text, visual, and acoustic |
| Alarm Functions | Power failure, adjustable high / low temperature, open door, probe failure, and low battery (72 hour battery backup for alarms) |
| Data Logging / External Connections | Voltage free contact for remote alarm, electronic data logger, RS 485 port, USB port for software update and data download, temperature chart recorder (optional) |
| Vacuum Release Port | No |
| Internal Light | No |
| Fixed Shelves / Adjustable Shelves | 0 / 0 |
| Interior Cabinet Material | Stainless steel |
| Exterior Cabinet Material | Electrogalvanized steel |
| Foam Material | Polyurethane |
| Insulation Thickness | 4.7 in. (12 cm) |
| Interior Dimensions (W x D x H) | 5.91 x 5.63 x 12.2 in. (15 x 14.3 x 31 cm) |
| Exterior Dimensions (W x D x H) | 15.75 x 24.8 x 26.18 in. (40 x 63 x 66.5 cm) |
| Weight | 139 lb. (63 kg) |
| Electrical Requirements | 110V, 50/60Hz, 5.6A |
- Inspect the display for pixel clarity and brightness, replacing any dim or dead pixels.
- Test all buttons for responsiveness, resistance, and durability; replace any that don’t meet standards.
- Check the door seal and lock for airtightness, replacing any compromised components.
- Run diagnostics on PCB test points for voltage and current accuracy, replacing faulty components.
- Verify compressor output and airflow, ensuring all internal fans function properly.
- Cross-check internal temperature probe accuracy with a NIST-traceable probe, recalibrating if needed.
- Inspect wiring for frays or tears, replacing compromised sections as necessary.
- Test the start capacitor's capacitance and replace if it’s outside the specified range.
- Replace all internal filters and thoroughly clean condenser fins for efficient heat dissipation.
- Verify the alarm battery holds a full charge and replace if there is any degradation.
- Operate the unit for 72 hours to confirm stable temperatures and operational consistency.
- Perform a final cosmetic check, repairing or touching up surfaces as needed for a professional appearance.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Inspect display for pixel issues and replace if needed | Completed | |
| Test button functionality and replace any defective buttons | Completed | |
| Examine door seal and lock functionality; replace if compromised | Completed | |
| Conduct PCB test point diagnostics and replace as needed | Completed | |
| Verify compressor and internal fan functionality | Completed | |
| Confirm temperature probe accuracy with NIST-traceable probe | Completed | |
| Inspect all wiring for frays, tears, or breakages | Completed | |
| Test start capacitor capacitance range; replace if needed | Completed | |
| Replace all internal filters and clean condenser fins | Completed | |
| Test alarm battery for full functionality | Completed | |
| Run 72-hour test with data recorder to confirm stable temperatures | Completed | |
| Conduct cosmetic inspection and address any issues | Completed |



Click Here to View all the Technical Specs for the Arctiko ULUF 15 -86C Ultra Low Undercounter Freezer