Eppendorf Thermostat C, Catalog # 5383
The Eppendorf Thermostat C, Catalog # 5383 makes effectively controlling liquid sample temperatures possible with the optimally balanced heating and cooling elements. A wide variety of Eppendorf SmartBlocks are available for the Eppendorf ThermoStat C. Blocks can be quickly and easily changed without the use of tools and can be used with a variety of lab vessels includes, micro test tubes, conical tubes, microplates, PCR plates, and cryogenic tubes. There are a total 15 program slots available and the most common temperatures can be easily selected. The Lid ensure uniform temperature control and protects samples from unwanted light exposure.
All of our equipment will be fully tested to perform at factory specifications before being shipped.The Eppendorf Thermostat C, Catalog # 5383 includes:
- PCR-96 Block & Lid
- Operator's Manual
- Power Cord
- Full 180 Day Parts and Labor Warranty
Eppendorf Thermostat C, Catalog # 5383 Specifications
|
Temperature Range |
-10°C - 110°C, set in 1°C increments |
|
Temperature Accuracy |
±0.5°C at 20°C - 45°C
±0.1°C at < 20°C or > 45°C |
|
Temperature Homogeneity |
In
the range of 20°C - 45°C
max.
±0.5°C for all positions of the thermoblock
|
|
Heating Rate |
5.5°C/min
|
|
Cooling Rate |
Maximum
if set above ambient
2.0°C/min
if temperature is set between ambient and 30°C below ambient
|
|
Dimensions (W x D x H) |
20.6 x 30.4 x 13.6 cm (8.1 x 12 x 5.4 in) |
|
Display |
Digital |
|
Time Setting |
Cycle times of 5s to 99:30 h or unlimited |
|
Weight |
4.4 kg (9.7 lbs) |
- Confirm stability and accuracy of power supply and PCB voltage outputs
- Inspect display integrity, ensuring pixel clarity and replacing any degraded or non-functional elements
- Verify complete functionality and responsiveness of all control buttons, switches, and knobs
- Conduct thorough inspection of internal wiring and all electrical connections for continuity; replace or secure any degraded or substandard components
- Examine block holder platform for alignment, obstructions, or error-inducing irregularities
- Perform detailed inspection of motor bearings, assessing for wear or misalignment, and replace if performance deviates from specifications
- Calibrate rotational speed precisely using a NIST-traceable tachometer for compliance with operational standards
- Calibrate temperature accuracy using a NIST-traceable temperature probe, validating readings across the operational range
- Ensure timer precision by validating functionality and consistency against set parameters
- Conduct a comprehensive cosmetic inspection, verifying all surfaces and external components meet quality standards
Technician Inspection and Recertification Checklist: Thermo Mixer
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment| Task | Completed? | Remarks? |
| Confirm stability and accuracy of power supply and PCB voltage outputs | Completed | |
| Inspect display integrity, ensuring pixel clarity and replacing any degraded elements | Completed | |
| Verify functionality and responsiveness of all control buttons, switches, and knobs | Completed | |
| Inspect internal wiring and connections for continuity, replacing or securing degraded components | Completed | |
| Examine block holder platform for alignment, obstructions, or irregularities | Completed | |
| Inspect motor bearings for wear or misalignment, replacing if necessary | Completed | |
| Calibrate rotational speed using an NIST-traceable tachometer | Completed | |
| Calibrate temperature with an NIST-traceable probe, validating accuracy | Completed | |
| Ensure timer precision by validating against set parameters | Completed | |
| Conduct cosmetic inspection for quality standard compliance | Completed |