Hirayama HVE-50 Autoclave Sterilizer
The Hirayama HVE-50 autoclave sterilizer is a self-contained, portable, top-loading autoclave with auto exhaust and warming cycles. The top loading feature with the lid opening upward is not only a great space-saving design benefit, it also means that this sterilizer is also desirable and particularly suited for the sterilizations of large fermenter vessels, so it is the perfect companion for fermenters like the Winpact fermenter. A dual-sensing lid interlock shut prevents lid from opening when chamber is pressurized or when temperature exceeds 97C. The HVE-50 autoclave also features an agar melting mode for melting agar and maintaining it at liquid temperature. This also is convenient for hot, faster start-up. The autoclave has a convenient one-touch lever to easily open and close chamber lid. An in-process display shows the status and the progress of sterilization cycle. Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
The Hirayama HVE-50 is in Brand New condition and is ready to be shipped promptly.
The Hirayama HVE-50 Autoclave Sterilizer includes:
- Power Cord
- Operator's Guide
- Full 180 Day Parts and Labor Warranty
Hirayama HVE-50 Autoclave Sterilizer Specifications
|
Model
|
HVE-50
|
|
Serial Number
|
30614016509
|
|
Production date
|
01/2014
|
|
Chamber Capacity
|
0.054247 M^3
|
|
Sterilization Temp Range |
105C to 135C |
|
Maximum Pressure
|
0.255 MPa
|
|
Sterilization Timer
|
1 to 250 minutes |
|
Pressure Gauge
|
0 to 0.4 MPa
|
|
Electric power
|
2.0 kW
|
|
Voltage
|
120V, 50/60Hz |
- Verify power supply output to ensure precise voltage delivery as per equipment specifications
- Check full display functionality, replacing any dead or dim pixels for optimal clarity
- Confirm unit is level to maintain stability and accurate operational performance
- Inspect door seal integrity, replacing if any wear or damage compromises airtight performance
- Examine and clean both external and internal filters to ensure unobstructed airflow and system efficiency
- Execute comprehensive cycle testing to validate consistent operation
- Verify printer functionality (if applicable) to ensure precise print outputs without error
- Assess internal plumbing system for any leaks or pressure inconsistencies
- Inspect all electrical connections and wiring for secure attachment and optimal conductivity
- Verify functionality of internal switches to ensure reliable engagement and operational control
- Inspect and clean the water reservoir to maintain purity and prevent contamination
- Confirm accuracy of pressure readings, recalibrating if deviations are identified
- Perform final test cycles, ensuring zero errors for validated operational readiness
Technician Inspection and Recertification Checklist: Autoclaves
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment| Task | Completed? | Remarks? |
| Verify power supply output voltages | Completed | |
| Check display functionality and replace dead/dim pixels | Completed | |
| Confirm unit leveling for stability | Completed | |
| Inspect and replace damaged door seal | Completed | |
| Clean external and internal filters for airflow efficiency | Completed | |
| Conduct comprehensive cycle testing | Completed | |
| Confirm printer functionality (if applicable) | Completed | |
| Assess plumbing for leaks or pressure issues | Completed | |
| Inspect electrical connections for secure and optimal conductivity | Completed | |
| Verify internal switch functionality | Completed | |
| Inspect and clean water reservoir | Completed | |
| Confirm pressure reading accuracy and recalibrate if needed | Completed | |
| Perform final test cycles with zero errors | Completed |