Agilent 1260 Infinity I HPLC System w/ DAD Agilent 1260 Infinity I HPLC System w/ DAD

Agilent 1260 Infinity HPLC System w/ DAD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 ƒ” 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 ƒ” 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cells

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC

Our Price: $53,995.00
Sale Price: $41,995.00
Money Saved: $12,000.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD

Agilent 1260 Infinity I HPLC System w/ Quat Pump, DAD, & FLD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 ƒ” 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 ƒ” 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cell

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC

FLD Detector

Specification

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

Single wavelength operation: ‚ RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell ‚ RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h

Pulse frequency

296 Hz for single signal mode 74 Hz for economy mode

Excitation Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Reference System

In-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200 ‚ 400 nm, 10 nm step) Step size: 1 ‚ 20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Our Price: $55,895.00
Sale Price: $47,995.00
Money Saved: $7,900.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ DAD & FLD Agilent 1260 Infinity I HPLC System w/ DAD & FLD

Agilent 1260 Infinity I HPLC System w/ DAD & FLD Specifications

DAD Detector Specification
Detection Type 1024-element photodiode array
Light Source Deuterium and tungsten lamps
Wavelength Range 190 - 640 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.7 ƒ” 10^-5 AU at 254 nm and 750 nm
Drift < 0.9 ƒ” 10^-3 AU/hr at 254 nm
Linear Absorbance Range
> 2.0 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm / programmable slit
Diode Width < 1 nm
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cell

Standard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC

FLD Detector

Specification

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

Single wavelength operation: ‚ RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell ‚ RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h

Pulse frequency

296 Hz for single signal mode 74 Hz for economy mode

Excitation Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Reference System

In-line excitation measurement

Timetable programing

up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters

Spectrum acquisition

Excitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200 ‚ 400 nm, 10 nm step) Step size: 1 ‚ 20 nm Spectra storage: All

Wavelength characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Our Price: $54,995.00
Sale Price: $47,995.00
Money Saved: $7,000.00
1 in stock!
Agilent 1260 Infinity II LC System w/ DAD Agilent 1260 Infinity II LC System w/ DAD

Agilent 1260 Infinity II LC System w/ DAD Specifications

DAD Detector Specification

Detection Type

1024-element photodiode array
Light Source Deuterium and tungsten lamps
Data Rate Up to 120 Hz
Wavelength Range 190 - 950 nm
Short Term Noise (ASTM) Single and Multi-Wavelength

< ± 0.7 x 10^-5 AU, at 254 and 750 nm

Drift < 0.9 x 10^-3 AU/h at 254 nm
Linear Absorbance Range > 2 AU (5%) at 265 nm
Wavelength Accuracy ± 1 nm
Wavelength Bunching 1 - 400 nm
Slit Width 1, 2, 4, 8, 16 nm
Diode Width < 1 nm
Flow Cell Standard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum
Time Programmable Wavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode

Our Price: $54,995.00
Sale Price: $47,995.00
Money Saved: $7,000.00


Agilent 1260 Infinity II LC System w/ Vialsampler & DAD Agilent 1260 Infinity II LC System w/ Vialsampler & DAD

Agilent 1260 Infinity II LC System w/ Vialsampler & DAD Specifications

DAD Detector Specification

Detection Type

1024-element photodiode array
Light Source Deuterium lamp
Number of Signals 8
Maximum Sampling Rate 240 Hz (both spectra and signals)
Wavelength Range 190 - 640 nm
Short Term Noise

With 10 mm Max-Light cartridge cell: < ± 3 x 10-6 AU at 230/4 nm, slit width 4 nm, TC 2 s , ASTM

With 60 mm Max-Light cartridge cell (included): < ± 0.6 x 10-6 AU at 230/4 nm, slit width 4 nm, TC 2 s , ASTM

Drift < 0.5 x 10-3 AU/h at 230 nm
Linearity > 2.0 AU (5%) at 265 nm, typically 2.5 AU (5%)
Wavelength Accuracy ± 1 nm
Wavelength Bunching 2 - 400 nm in steps of 1 nm
Wavelength Precision < ± 0.1 nm
Slit Width 1, 2, 4, 8 nm
Diode Width ~0.5 nm
Flow Cell Max-Light cartridge cell (high sensitivity): 60 mm
Spectral Tools Data analysis software for spectra evaluation, including spectral libraries and peak purity functions

Our Price: $56,995.00
Sale Price: $47,395.00
Money Saved: $9,600.00
1 in stock!
Agilent 1260 Infinity II LC System w/ Vialsampler & VWD Agilent 1260 Infinity II LC System w/ Vialsampler & VWD

Agilent 1260 Infinity II LC System w/ Vialsampler & VWD Specifications

VWD Detector Specification

Detection Type

Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Noise

< ± 0.25 x 10^-5 AU, at 230 nm (single wavelength detection)

< ± 0.80 x 10^-5 AU, at 230 nm and 254 nm (dual wavelength detection)

Drift < 1 x 10^-4 AU/h at 230 nm
Linearity > 2.5 AU upper limit
Wavelength Accuracy ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Wavelength Precision < ± 0.1 nm
Slit Width 6.5nm typical over whole wavelength range
Time Programmable Wavelength, polarity, peak width, lamp on/off
Flow Cell Standard: 14 µl volume, 10 mm cell path length and 40 bar (588 psi) pressure maximum
Spectral Tools Stop-flow wavelength scan

Our Price: $56,995.00
Sale Price: $44,395.00
Money Saved: $12,600.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ VWD Agilent 1260 Infinity I HPLC System w/ VWD

Agilent 1260 Infinity HPLC System w/ VWD Specifications

VWD Detector Specification
Detection Type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.5 x 10^-5 AU at 254 nm
Drift 3 x 10^-4 AU/hr at 254 nm
Linearity
> 2.0 AU (5%) upper limit
Band Width 6.5 nm typical
Maximum Data Rate 55 Hz
Signal Data Rate Up to 80 Hz
Spectra Data Rate Up to 80 Hz
Flow Cells

Standard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum

Control and Data Evaluation Agilent ChemStation for LC
Analog Outputs

Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN

Safety and Maintenance

Extensive diagnostics, error detection, and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP Features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

Housing All materials recyclable

Our Price: $41,995.00
Sale Price: $37,995.00
Money Saved: $4,000.00
1 in stock!
Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector

Agilent 1260 Infinity I G1364B Preparative-Scale Fraction Collector Specifications

Delay Volume (in ul)

Fraction collector inlet to diverter valve: ~500 (typical, depends on length of the tubing)

Diverter valve: ~15

Diverter valve to needle: ~110

Needle: ~5

Maximum System Flow 100 mL/min
Maximum Capacity 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-position, 13-port selector valve (PN G1160A)
Trigger Modes

Time slices

Peak (threshold, up- / downslope)

Timetable (combination of time intervals and peak)

Manual trigger (supported only with Agilent Instant Pilot G4208A)

Operating Modes

Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position

Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste

Included Tray Full tray with 215 test tubes (12 mm OD, max. height 100 mm, ~7 ml / tube)
Electrical Requirements 100-240V, 50/60Hz

Our Price: $8,995.00
1 in stock!
Agilent 1260 Infinity I HPLC System w/ VWD & FLD Agilent 1260 Infinity I HPLC System w/ VWD & FLD

Agilent 1260 Infinity I HPLC System w/ VWD & FLD Specifications

VWD Detector Specification
Detection Type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short Term Noise (ASTM) Single and Multi-Wavelength < ± 0.5 ƒ” 10^-5 AU at 254 nm
Drift 3 ƒ” 10^-4 AU/hr at 254 nm
Linearity > 2.0 AU (5%) upper limit
Band Width 6.5 nm typical
Maximum Data Rate 55 Hz
Flow Cell

Standard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum

FLD Detector

Specification

Detection Type

Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications

Single wavelength operation: ‚ RAMAN (H2O) > 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell ‚ RAMAN (H2O) > 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) > 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.

Light source

Xenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h

Pulse frequency

296 Hz for single signal mode 74 Hz for economy mode

Excitation Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 300 nm

Emission Monochromator

Range: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F/1.6, blaze: 400 nm

Wavelength Characteristic

Repeatability+/- 0.2 nm Accuracy+/- 3 nm setting

Flow cells

Standard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz

Our Price: $57,595.00
Sale Price: $49,995.00
Money Saved: $7,600.00
1 in stock!
Agilent 1260 Infinity I HPLC G1329B Autosampler Agilent 1260 Infinity I HPLC G1329B Autosampler

Agilent 1260 Infinity HPLC G1329B Autosampler Specifications

Pressure Operating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)

GLP Features

Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications

Controller-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output

Safety Features

Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Injection Range

0.1 ‚ 100 µl in 0.1 µl increments (recommended 1 µl increments)

Up to 1500 µl with multiple draw (hardware modification required)

Replicate Injections

1 ‚ 99 from one vial

Precision

Typically < 0.25 % RSD of peak areas from 5 to 100 µl

Typically < 1 % RSD of peak areas from 1 to 5 µl

Minimum Sample Volume

1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial

Carryover

Typically < 0.1 %, < 0.05 % with external needle cleaning

Sample Viscosity Range

0.2 ‚ 50 cp

Metering Devices

Metering pump in high pressure flow path

Sample Capacity

100 ƒ” 2 ml vials in 1 tray

40 ƒ” 2 ml vials in ½ tray

15 ƒ” 6 ml vials in ½ tray (Agilent vials only)

Injection Cycle Time

50 seconds for draw speed 200 µl/min, ejection speed 200 µl/min, injection volume 5 µl

Our Price: $8,995.00
1 in stock!