{"product_id":"thermo-scientific-french-press-cell-disrupter","title":"Thermo Scientific French Press Cell Disrupter","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eThermo Scientific French Press Cell Disrupter\u003c\/h1\u003e\n\t\u003cbr\u003eThe Thermo Scientific French Press Cell Disrupter is a hydraulic press which uses control valves and a motor driven pump to vary hydraulic pressure generated by the press. The Press offers the advantages of dual-range, single-control pressure selection and fully regulated working pressure through the entire operating stroke. These special features differentiate the motor-driven French Press Cell Disrupter from manual presses. The Press is designed for use with the French Pressure Cells manufactured by Thermo to produce a selected pounds-per-square inch (psi) value inside a French Pressure Cell. It can accommodate both 1-in and 3\/8-in diameter piston French Pressure Cells. The Thermo Scientific French Press provides a rapid and effective mechanism for gentle disruption of cell membranes and walls. This pressure-induced process results in more uniform and complete disruption than possible with other mechanical or ultrasonic methods. The French Press is capable of exerting up to 40,000psi of pressure resulting in excellent performance.\n\t\u003cbr\u003e\u003cbr\u003eThe Thermo Scientific French Press Cell Disrupter is designed for use in the following applications: Enzymatic preparation and isolation; cell extract preparation; bacterial and plant tissue disintegration; recovery of intercellular proteins and nucleic acid; preparation of viral antigens for EIA test kits; membrane preparation for phizobia and pseudomonads; disruption of cells for pigment analysis. \u003cb\u003e(Please Note: A Pressure Cell is NOT Included and is required for operation).\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Thermo Scientific French Press Cell Disrupter includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eThermo Scientific French Press Cell Disrupter Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"spec-table\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eWith 40K Pressure Cell\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiameter\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3\" OD (7.6 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tClosed Height\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t11.38 in (28.9 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOpen Height\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t14.0 in (35.6 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t35 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t40K Maximum Working Pressure\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t40,000 psi\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMinimum Volume (First Run)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t1.0 ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMinimum Volume (Additional Runs)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.5 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Volume\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t40 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eWith Mini-Cell Pressure Cell\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiameter\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2.38 in (6.0 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tClosed Height\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.13 in (15.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOpen Height\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tapprox. 8.12 in to 8.25 in (approx. 20.6 cm to 21 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.7 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Working Pressure\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t20,000 psi\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Compressive Force on Piston\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2200 lbs (999 kg). A reading of 900 lbs on the Press at MED range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMinimum Volume (First Run)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.37 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMinimum Volume (Additional Runs)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.3 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Volume\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.7 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eGeneral\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t18.25 in x 18.25 in x 34.5 in\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t240 lbs (109 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t120V, 60Hz, 6.6A\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Thermo_Scientific_French_Press_Cell_Disrupter_-_Marshall_Scientific.pdf?v=1779995556\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Thermo_Scientific_French_Press_Cell_Disrupter_Manual_-_Marshall_Scientific.pdf?v=1779995560\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2440.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42475407081562,"sku":"TS-FPCS","price":2920.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/TS-FPCS-2.jpg?v=1761237914","url":"https:\/\/marshallscientific.com\/products\/thermo-scientific-french-press-cell-disrupter","provider":"Marshall Scientific","version":"1.0","type":"link"}