{"product_id":"sorvall-legend-mach-1-6-benchtop-centrifuge","title":"Sorvall Legend Mach 1.6 Benchtop Centrifuge","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eSorvall Legend Mach 1.6 Benchtop Centrifuge\u003c\/h1\u003e\n\t\u003cbr\u003eThe Sorvall Legend Mach 1.6 Benchtop Centrifuge offers the processing versatility, sample capacity, and sheer value that today's busy laboratories demand with five interchangeable biocontainment rotors available for a host of applications. The Sorvall Legend Mach 1.6 features a maintenance-free brushless induction drive that offers state of the art technology and power, spinning more tubes, at higher RCF’s, more rapidly than competitive instruments. The SMARTspin Imbalance Detection System provides optimum run stability for all rotors at all speeds and allows for eye balancing of sample tubes. Automatic rotor recognition offers reliable protection against incorrect parameter settings and ensures reproducible run conditions. The Sorvall Legend Mach 1.6 Benchtop Centrifuge enables users to set up to 4 user programs, as well as including other features such as RCF pre-selection, quick run, and more for ease-of-use. The Sorvall Legend Mach 1.6 Benchtop Centrifuge is ideal for clinical testing, microbiology, pharmaceutical, clinical testing, biotechnology, and general laboratory environments. \u003cb\u003eThe included rotor reaches a maximum speed of 4,500 RPM. \u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003ePlease confirm this rotor meets your application needs and request a different rotor, if necessary. Available rotors can be found in our \u003ca href=\"https:\/\/www.marshallscientific.com\/rotor_compatibility_guide_a\/326.htm\" target=\"_blank\"\u003eRotor Compatibility Guide\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Sorvall Legend Mach 1.6 Benchtop Centrifuge includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e75002000 Swing Bucket Rotor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e75002001 Rectangular Buckets with Aerosol Lids\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003e2 Sets of 50ml Adapters (Cat. #: 75005386)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eNIST Centrifuge Calibration and Preventative Maintenance Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003ePower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan class=\"hidden-car\"\u003e\u0026gt; \u003c\/span\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eSorvall Legend Mach 1.6 Benchtop Centrifuge Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"spec-table\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Speed\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t15,000 RPM (4,500 RPM with included rotor)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum RCF\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t24,652 x g (4,234 x g with included rotor)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t4 x 400ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tN\/A\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimer\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 9 hours 59 minutes, or continuous run (hold)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAcceleration Rates\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t9\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeceleration Rates\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t9\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tProgram Memory\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Noise Level\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 64 dBa\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (H x W x D)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t24 x 22 x 26 in. (60 x 55 x 66.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t203 lb. (92 kg.)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t120V, 60Hz, 12A, 1220W\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRefrigeration\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eNo Refrigeration\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2 class=\"pm-header\"\u003ePreventative Maintenance Performed on The Sorvall Legend Mach 1.6 Benchtop Centrifuge\u003c\/h2\u003e\n\t\u003cul class=\"pm-list\"\u003e\n\t\t\u003cli\u003eDoor Latch Assembly Checked for Full Function\u003c\/li\u003e\n\t\t\u003cli\u003eDoor Hinges are Checked and Lubed as Needed\u003c\/li\u003e\n\t\t\u003cli\u003eDrive Belt is Checked for Rips and Tears and Replaced if Needed\u003c\/li\u003e\n\t\t\u003cli\u003eRotors and O-rings are Lubed as Needed\u003c\/li\u003e\n\t\t\u003cli\u003eLamps and Display are Checked and Replaced if Dim\u003c\/li\u003e\n\t\t\u003cli\u003eLine Cord is Checked for Signs of Fray or Damage and Replaced Accordingly\u003c\/li\u003e\n\t\t\u003cli\u003eInternal Circuitry is Checked for Faulty\/Shorted Components and Replaced Accordingly\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003cbr\u003e\u003ca href=\"https:\/\/www.marshallscientific.com\/Articles.asp?ID=326\" target=\"blank\" style=\"background-color: initial; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/rotor_compatibility_guide_e72bc5e0-4ed9-4e89-9404-4cb7b9a38d8d.png?v=1779994525\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003co:p\u003e \u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Sorvall_Legend_Mach_1.6_Centrifuge_-_Marshall_Scientific.pdf?v=1779994548\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2426.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.downloads-section {\n        justify-content: center;\n    }\n\u003c\/style\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42475203887194,"sku":"SO-LEGM16","price":3620.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/SO-LEGM16-2.jpg?v=1761233036","url":"https:\/\/marshallscientific.com\/products\/sorvall-legend-mach-1-6-benchtop-centrifuge","provider":"Marshall Scientific","version":"1.0","type":"link"}