{"product_id":"mj-research-ptc-100-thermal-cycler","title":"MJ Research PTC-100 Thermal Cycler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eMJ Research PTC-100 Thermal Cycler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eThermal Range\u003c\/b\u003e\u003cbr\u003e 0°C to 105°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eThermal Uniformity\u003c\/b\u003e\u003cbr\u003e± 0.4°C well-to-well\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eRamping Rate \u003c\/b\u003e\u003cbr\u003eUp to 1.2°C\/sec\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eCompatible with both 96-well and 60-well microplates for versatile sample processing\u003c\/li\u003e\n\u003cli\u003eOffers a wide temperature range from 0°C to 105°C with high accuracy (± 0.3°C)\u003c\/li\u003e\n\u003cli\u003eFeatures a heated lid for oil-free operation and easy pressure and height adjustment\u003c\/li\u003e\n\u003cli\u003eDesigned for durability, capable of enduring up to 10,000 temperature cycles\u003c\/li\u003e\n\u003cli\u003eAllows indefinite material storage at any temperature for accurate incubation rates\u003c\/li\u003e\n\u003cli\u003eStores approximately 320 programs with 14 pre-programmed protocols included\u003c\/li\u003e\n\u003cli\u003eEquipped with power-failure protection, preserving data for up to twelve hours after a power interruption\u003c\/li\u003e\n\u003cli\u003eFlexible ramping rates with up to 1°C\/sec for 60-well block and 1.2°C\/sec for 96-well block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/mj-100_2ff40d48-b239-4fa7-a508-a73cd0299c19.jpg?v=1779993265\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe MJ Research PTC-100 Thermal Cyler is a robust\nthermocycler that operates with \n\t\t\u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-96\" style=\"font-family: Arial;\"\u003e96-well\u003c\/a\u003e and \u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-60\" style=\"font-family: Arial;\"\u003e60-well\u003c\/a\u003e microplates. This thermocycler is\nreliable and easy-to-use, while also offering various temperature\nconfigurations from 0°C to 105°C with temp accuracy of ± 0.3°C. The PTC-100 has\na heated lid for oil-free operation, which allows for convenient pressure and\nheight adjustment via a thumbwheel. Crafted to withstand repeated cycling, the\nPTC-100 thermocycler can follow any temperature sequence up to 10,000 times and\ncan store material indefinitely at any temperature, allowing for highly\naccurate incubation rates. The MJ Research PTC-100 can store approximately 320\nprograms and comes with 14 pre-programmed protocols. Due to the PTC's\npower-failure protection feature, data is safe after power interruption for up\nto twelve hours.\n\t\t\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe MJ Research PTC-100 Thermal Cycler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n96 Well Alpha Block\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNIST Traceable Calibration Certificate\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eMJ Research PTC-100 Thermal Cycler Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-color: windowtext; border-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tThermal Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t0°C - 105°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tAccuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t± 0.5°C of programmed target at 60°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tThermal Uniformity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t± 0.4°C well-to-well within 30 sec of arrival at 60°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tRamping rate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t60-well block: up to 1°C\/sec\n\t\t\t\t\u003cbr\u003e96-well: up to 1.2°C\/sec\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t60-well block: 60 x 0.5 ml tubes \n\t\t\t\t\u003cbr\u003e96-well block: 96 x 0.2 ml tubes or\n  one 96-well plate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tLine Voltage\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"319\" valign=\"top\" style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t100-240 VAC rms (no adjustment needed among voltages within these\n  ranges)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003ePTC-100 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/PTC-100.pdf?v=1779993268\"\u003emanual\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003eWe also carry the \u003ca href=\"https:\/\/www.marshallscientific.com\/MJ-Research-PTC-150-Thermal-Cycler-p\/mj-150.htm\"\u003ePTC-150\u003c\/a\u003e, \u003ca href=\"https:\/\/www.marshallscientific.com\/ProductDetails.asp?ProductCode=MJ-G200\" style=\"background-color: initial; letter-spacing: -0.02em;\"\u003ePTC-200\u003c\/a\u003e, \u003ca href=\"https:\/\/www.marshallscientific.com\/MJ-Research-PTC-225-Gradient-Thermal-Cycler-p\/mj-225.htm\"\u003ePTC-225\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.marshallscientific.com\/MJ-Research-PTC-240-Gradient-Thermal-Cycler-p\/mj-240.htm\"\u003ePTC-240\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/PTC100_specs_68b9b1db-f29e-48a5-8706-daa5635a3b59.pdf?v=1779993272\" target=\"blank\"\u003e\u003cimg src=\"\/v\/vspfiles\/images\/marshdoc.png\"\u003eClick Here to View all the Technical Specs for the PTC-100\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/915.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":42502188433498,"sku":"MJ-100","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/MJ-100-2.jpg?v=1761897610","url":"https:\/\/marshallscientific.com\/products\/mj-research-ptc-100-thermal-cycler","provider":"Marshall Scientific","version":"1.0","type":"link"}