{"product_id":"biotek-elx405v-microplate-washer","title":"Biotek ELx405V Microplate Washer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eBiotek ELx405V Microplate Washer\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMicroplate Types\u003c\/b\u003e\u003cbr\u003e96- and 384-well\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eManifold Type\u003c\/b\u003e\u003cbr\u003e96-Tube Dual-Action manifold for 96- and 384-well washing\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eWash Speed \u003c\/b\u003e\u003cbr\u003e96-wells, 300 uL\/well, 3 cycles: \u0026lt;30 seconds; 384-wells, 100 uL\/well, 3 cycles: \u0026lt;80 seconds\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic buffer switching supports selection from up to four wash buffers or reagents\u003c\/li\u003e\n\u003cli\u003eProgrammable shaking and soaking provide added flexibility when configuring wash protocols\u003c\/li\u003e\n\u003cli\u003eAdjustable dispense volumes in 1 µL increments support precise protocol customization\u003c\/li\u003e\n\u003cli\u003eOnboard software allows users to create, edit, store, and run multiple protocols\u003c\/li\u003e\n\u003cli\u003eHigh-to-low adjustable flow rates accommodate a variety of washing requirements\u003c\/li\u003e\n\u003cli\u003eOptimized fluid delivery supports gentle processing for sensitive cell-based assays\u003c\/li\u003e\n\u003cli\u003eLow residual volumes help promote efficient aspiration and consistent assay performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ELX405V_Features.jpg?v=1786389276\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BioTek ELx405V Microplate Washer is a versatile automated plate washing system designed to support efficient processing of both 96- and 384-well microplates, the ELx405V provides flexibility for a broad range of microplate-based laboratory workflows. A 96-tube Dual-Action manifold supports both 96- and 384-well washing, while programmable shaking and soaking functions provide additional control over wash protocols. The ELx405V features integrated buffer switching, allowing automated selection from up to four buffer or reagent sources. Programmable wash cycles and adjustable dispense volumes enable protocols to be configured around specific assay requirements, while onboard software allows users to create, edit, and run multiple protocols directly from the instrument.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/p\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Biotek ELx405V Microplate Washer includes:\n\u003cul class=\"includes-list\"\u003e\n\u003cli\u003e(2) 4 Liter Waste Bottles\u003c\/li\u003e\n\u003cli\u003e(1) 4 Liter Buffer Bottle\u003c\/li\u003e\n\u003cli\u003eVacuum Pump\u003c\/li\u003e\n\u003cli\u003eVacuum Tubing with Connections\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBiotek ELx405V Microplate Washer Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100.036%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eMicroplate Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e96- and 384-well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eOnboard Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003eCreate, edit and run multiple protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eManifold Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e96-Tube Dual-Action manifold for 96- and 384-well washing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eVolume Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e50 to 3,000 uL\/well, in 1 uL increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eWash Cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e1-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 39.2px;\"\u003e\u003cstrong\u003eBuffer\/Reagent Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 39.2px;\"\u003eAuto switching module for up to 4 buffers (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eSupply Bottle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e4 L or 10 L (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eDispense Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e≤3% CV: 300 uL\/well (96-well washing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eResidual Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e\u0026lt;2 uL\/well (standard and deep well 96-well plates)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 39.2px;\"\u003e\u003cstrong\u003eWash Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 39.2px;\"\u003e96-wells, 300 uL\/well, 3 cycles: \u0026lt;30 seconds; 384-wells, 100 uL\/well, 3 cycles: \u0026lt;80 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eFlow Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003eHigh flow to low flow; Optimized rates for cell assays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eSterilization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003eChemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 39.2px;\"\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 39.2px;\"\u003e14 x 17 x 11 in. (35.6 x 43.2 x 27.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 19.6px;\"\u003e30 lb. (13.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 25.9804%; height: 39.2px;\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.5597%; height: 39.2px;\"\u003e100-240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Biotek_ELx405V_Microplate_Washer_-_Marshall_Scientific.pdf?v=1786389300\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2142.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003cstyle\u003e\n.downloads-section {\njustify-content: center;\n}\n\u003c\/style\u003e","brand":"BioTek","offers":[{"title":"Default Title","offer_id":43821260996698,"sku":"BIO-405V","price":4495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ed919bd8-0764-4a48-a17c-1b5da3ae462a_3c167911-fad3-4ba7-b93f-791c41ed05de.jpg?v=1786389339","url":"https:\/\/marshallscientific.com\/products\/biotek-elx405v-microplate-washer","provider":"Marshall Scientific","version":"1.0","type":"link"}