{"product_id":"binder-bd56-avantgarde-gravity-convection-incubator-cat-9010-0324","title":"Binder BD56 Avantgarde Gravity Convection Incubator, Cat #: 9010-0324","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eBinder BD56 Avantgarde Gravity Convection Incubator, Cat #: 9010-0324\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eVolume\u003c\/b\u003e\u003cbr\u003e56.6 L (2 cu. ft.)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003e+5°C above ambient to 100°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eTemperature Variation \u003c\/b\u003e\u003cbr\u003e±0.3 K at 37°C\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eGentle gravity convection heating for uniform temperature distribution\u003c\/li\u003e\n\u003cli\u003eEasy USB data logging with standard USB interface\u003c\/li\u003e\n\u003cli\u003eIntuitive LCD controller for simple operation\u003c\/li\u003e\n\u003cli\u003eProgrammable ramp function for controlled heating profiles\u003c\/li\u003e\n\u003cli\u003eDelayed ON and delayed OFF timer functions\u003c\/li\u003e\n\u003cli\u003eClass 3.1 independent temperature safety device for enhanced sample protection\u003c\/li\u003e\n\u003cli\u003eVisual temperature alarm for monitoring operating conditions\u003c\/li\u003e\n\u003cli\u003eOptimized heating system with low heat dissipation for outstanding energy efficiency\u003c\/li\u003e\n\u003cli\u003eLow installation requirements reduce operating costs and simplify placement\u003c\/li\u003e\n\u003cli\u003eRapid heating to operating temperature with fast recovery following door openings\u003c\/li\u003e\n\u003cli\u003eSupports up to four shelves with two standard shelves included\u003c\/li\u003e\n\u003cli\u003eHigh load capacity with up to 154 lb permitted chamber load and 66 lb per shelf\u003c\/li\u003e\n\u003cli\u003eCompact benchtop design ideal for research, pharmaceutical, clinical, and quality control laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/731a52d9-9350-43cb-9d12-3bf5c5dc5ced-Photoroom.png?v=1785508516\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Binder BD56 Avantgarde Gravity Convection Incubator, Cat #: 9010-0324 is designed to provide dependable, energy-efficient incubation for microbiology, pharmaceutical, clinical, and research laboratories. Utilizing gravity convection technology, the BD56 delivers gentle, uniform heating that is ideal for routine incubation of sensitive samples while maintaining excellent temperature stability and consistency. With an operating temperature range from 5°C above ambient to 100°C, the incubator offers the flexibility required for a wide variety of laboratory applications, while its optimized heating system minimizes heat dissipation and reduces installation requirements for improved energy efficiency.\u003cbr\u003e\u003cbr\u003eEngineered for ease of use, the BD56 features an intuitive LCD controller with programmable ramp and timer functions, allowing users to easily configure temperature profiles and automated start and stop times. A standard USB interface enables convenient data logging and simplifies documentation of incubation conditions. The incubator also incorporates a Class 3.1 independent temperature safety device and a visual temperature alarm to help protect valuable samples throughout operation. Exceptional thermal performance is achieved through temperature uniformity of ±0.3 K at 37°C and ±1.1 K at 100°C, with fluctuations as low as ±0.1 K at 37°C, ensuring accurate, repeatable results for demanding laboratory workflows.\u003c\/p\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Binder BD56 Avantgarde Gravity Convection Incubator, Cat #: 9010-0324 includes:\n\u003cul class=\"includes-list\"\u003e\n\u003cli\u003e2 x Shelves\u003c\/li\u003e\n\u003cli\u003eNIST Calibration and Preventative Maintenance Report\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBinder BD56 Avantgarde Gravity Convection Incubator, Cat #: 9010-0324 Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\" style=\"width: 100.036%; height: 215.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e56.6 L (2 cu. ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e+5°C above ambient to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eTemperature Variation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e±0.3 K at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eTemperature Fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e±0.1 K at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eHeating-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e45 min to 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eRecovery Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e16 min (after 30-second door opening at 37°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eMaximum Load per Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e66 lb (30 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eInterior Dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e14.1 x 14.9 x 16.5 in. (36.0 × 38.0 × 42.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eExterior Dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e22.1 x 22.3 x 24.6 in. (56.0 x 56.5 x 62.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e86 lb. (39 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.3636%; height: 19.6px;\"\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1765%; height: 19.6px;\"\u003e120V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Binder_BD56_Avantgarde_Gravity_Convection_Incubator_Cat._9010-0324_-_Marshall_Scientific.pdf?v=1785508734\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Binder_BD56_Avantgarde_Gravity_Convection_Incubator_Cat._9010-0324_Manual_-_Marshall_Scientific.pdf?v=1785508736\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2142.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e","brand":"Marshall Scientific","offers":[{"title":"Default Title","offer_id":43781751079002,"sku":"BI-BD56","price":1995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/bb72d6b0-2503-45d2-9d53-8ef6852ce2da_3f3a623b-aa65-4bfc-a804-3be01340121c.jpg?v=1785790139","url":"https:\/\/marshallscientific.com\/products\/binder-bd56-avantgarde-gravity-convection-incubator-cat-9010-0324","provider":"Marshall Scientific","version":"1.0","type":"link"}