{"product_id":"agilent-6545a-q-tof-mass-spectrometer","title":"Agilent 6545A Q-TOF Mass Spectrometer","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 6545A Q-TOF Mass Spectrometer\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Range\u003c\/b\u003e\u003cbr\u003em\/z 100 to 10,000\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMass Accuracy\u003c\/b\u003e\u003cbr\u003eLess than 0.8 ppm RMS\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSpectral Acquisition Rate\u003c\/b\u003e\u003cbr\u003e50 spectra\/second\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eRaises the standard for mid-range Q-TOF instruments with significantly higher resolving power and sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eUp to five times increased sensitivity over previous models, ideal for small molecule analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a fast and powerful new autotune capability to optimize performance effortlessly\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncorporates robust ion optics and beam shaping technology to extend maintenance intervals and enhance consistency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with new high voltage pulsers and power supplies for enhanced mass resolution and accuracy up to 0.8 ppm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes the advanced MassHunter software suite with powerful data-mining tools for faster, more accurate analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers a wide dynamic range of up to five decades for comprehensive sample analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eQuick switching between positive and negative ion modes, optimizing time efficiency in analytical workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnhanced electronics and software algorithms support exceedingly high data acquisition rates\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomated slicer assembly and continuous refinement in ion optics design combine to deliver robust performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eNew-generation detector offers significantly improved longevity, maintaining high sensitivity and a wide dynamic range\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6545AMS2_72f44219-2d75-4f47-a998-3f804691e75e.jpg?v=1779985789\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 6545A Q-TOF Mass Spectrometer represents a significant advancement in mid-range quadrupole time-of-flight mass spectrometry, offering an unparalleled combination of resolving power and sensitivity, which is estimated to be up to five times greater than previous models. This instrument is expertly designed for diverse applications including pharmaceutical research, food safety, environmental testing, metabolomics, lipidomics, and other small molecule analyses. Featuring a newly developed fast autotune technology, the 6545A enhances sensitivity specifically for small molecules, improving detection limits and maintaining the integrity of fragile compounds. This innovative autotune also streamlines the optimization process, making it faster and more efficient, like an autofocus system in cameras but for mass spectrometry.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe system's robust ion optics are engineered to provide greater durability and consistency in results, extending the intervals between required maintenance. The introduction of new ion beam shaping optics further stabilizes the ion flow, enhancing analytical consistency and prolonging instrument uptime. Highly sophisticated new-generation electronics and power supplies increase the mass resolution performance and enhance mass accuracy to an impressive 0.8 ppm. These features ensure high precision in mass determination, crucial for complex sample analyses.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAgilent has also integrated cutting-edge enhancements in the MassHunter software suite with this system. These advancements include powerful data-mining capabilities that allow users to rapidly and accurately process and interpret analytical data, not just identifying peaks and data points, but also providing comprehensive answers based on the chemical data. The 6545A Q-TOF supports an extensive dynamic range of up to five decades, accommodating a wide variety of sample concentrations within a single analysis. It covers a broad mass range from m\/z 50 to 10,000, allowing for flexible and extensive molecular weight analysis. The system's spectral acquisition rate is notably high, capturing 50 spectra per second in MS mode and 30 MS\/MS spectra per second, which facilitates high-throughput screening and detailed product ion analysis in MS\/MS mode.\n\t\u003cbr\u003e\u003cbr\u003e\n\tTransitioning between positive and negative ion modes is seamless and swift, with a cycle completion time of just 1.5 seconds. This feature is particularly valuable in labs performing comprehensive compound analyses, as it minimizes downtime and maximizes productivity. Overall, the Agilent 6545A Q-TOF is designed to boost laboratory efficiency and analytical confidence, providing robust, high-productivity, and high-sensitivity performance across a variety of demanding applications. It sets a new standard for Q-TOF instruments, making it an essential tool for scientists seeking to push the boundaries of what is possible in their research.\n\t\u003cbr\u003e\u003cbr\u003e\u003cb\u003eThis Agilent MS system was recertified and calibrated by a factory trained engineer and is ready to ship on demand. This system comes with everything needed for easy installation and setup. All of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/b\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 6545A Q-TOF Mass Spectrometer includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nAgilent 6545A Q-TOF Mass Spectrometer\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent MS40+ Rotary Vane Vacuum Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent G1958B Jet Stream Electrospray Ionization Source\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent MassHunter B.09.01 Acquisition and Data Analysis Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent MassHunter BioConfirm Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Diagnostics Report \u0026amp; Mass Spec Tuning Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 6545A Q-TOF Mass Spectrometer Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"spec-table\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity, MS Mode, Electrospray On-Column, 400 uL\/min Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t500:1 RMS (1 pg LC\/MS injection of reserpine. Signal-to-noise for the reserpine (M+H)+ at m\/z 609.2807 while maintaining a resolution of 40,000 at m\/z 2,722 in 4 GHZ mode)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSensitivity, MS\/MS Mode, Electrospray On-Column, 400 uL\/min Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1,500:1 RMS (1 pg LC\/MS injection of reserpine. Signal-to-noise for most intense product ions (174, 195, 397, and 448 m\/z) while maintaining a resolution of 40,000 at m\/z 2,722 in 4 GHZ mode)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Resolving Power\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t45,000 FWHM at m\/z 2,722 (measured after automatic tuning procedure)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy - MS Mode, Electrospray On-Column, 400 uL\/min\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLess than 0.8 ppm RMS as measured from 10 repeat injections (measured at the (M+H)+ ion of reserpine (m\/z 609.2807) using an internal mass reference)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Accuracy - MS\/MS Mode, Electrospray On-Column, 400 uL\/min\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLess than 2 ppm RMS on m\/z 397 as measured from 10 repeat injections (product ion m\/z 397 for reserpine)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDynamic Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 5 decades (intrascan dynamic range on co-eluting components)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMass Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tm\/z 100 to 10,000 for extended mass range\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tm\/z 50 to 1,700 or 50 to 3,200 for both high resolution and extended dynamic range modes\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tQuadrupole up to m\/z 4,000\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Acquisition Rate, MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t50 spectra\/second (m\/z 50 to 1,700 in MS mode while maintaining a resolution of 40,000 at m\/z 2,722 in 4 GHZ mode)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Acquisition Rate, MS\/MS Mode\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t30 MS\/MS spectra\/second (m\/z 50 to 1,700 in MS\/MS mode while maintaining a resolution of 40,000 at m\/z 2,722 in 4 GHZ mode)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPositive to Negative Switching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.5 seconds (complete cycle switching from positive to negative and positive modes allow for stabilization time)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x D x W)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t76 x 30 x 48 in. (193 x 76.2 x 121.9 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t375 lb. (170 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t200-240VAC, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable class=\"spec-table\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd colspan=\"2\" width=\"623\"\u003e\n\t\t\t\u003cp style=\"text-align: center;\"\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tModel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tDell Optiplex 7010 Desktop PC\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tProcessor\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tIntel Core i5-6500 Processor 3.2GHz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tRAM\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t16GB\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tHard Drive\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\t250GB Internal SSD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tOperating System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\tWindows 10 Professional, 64bit\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6545A_Q-TOF_Mass_Spectrometer_-_Marshall_Scientific.pdf?v=1779985793\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6545A_Q-TOF_Mass_Spectrometer_Manual_-_Marshall_Scientific.pdf?v=1779985797\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_6545A_Q-TOF_Mass_Spectrometer_Site_Preparation_Guide_-_Marshall_Scientific.pdf?v=1779985801\" target=\"blank\"\u003e\n\t\t\tSite Prep Guide Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2889.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474496065626,"sku":"AG-6545AMS","price":138160.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-6545AMS-2.jpg?v=1761206857","url":"https:\/\/marshallscientific.com\/products\/agilent-6545a-q-tof-mass-spectrometer","provider":"Marshall Scientific","version":"1.0","type":"link"}