{"product_id":"agilent-1290-infinity-ii-hplc-system-w-dad","title":"Agilent 1290 Infinity II HPLC System w\/ DAD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1290 Infinity II HPLC System w\/ DAD\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 to 640 nm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e\u0026gt;0.001 to 5.0 mL\/min, in 0.001 mL\/min increments\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003eUp to 130 MPa (1300 bar) at 0 to 2 mL\/min\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eComplete four-module UHPLC stack rated to 1300 bar for conventional HPLC and ultra-high-pressure methods\u003c\/li\u003e\n\u003cli\u003eFlexible Pump with low-pressure quaternary gradient formation from an integrated four-solvent valve\u003c\/li\u003e\n\u003cli\u003eDual-piston servo-controlled hydraulics with active damping for pressure pulsation under 1%\u003c\/li\u003e\n\u003cli\u003eIntelligent System Emulation Technology (ISET) for transferring legacy methods with retention times intact\u003c\/li\u003e\n\u003cli\u003eFlow-through needle Multisampler with 0.1 to 20 µL injections and carryover below 30 ppm\u003c\/li\u003e\n\u003cli\u003eVial and microtiter plate handling in configurable single-, double-, and triple-height drawers\u003c\/li\u003e\n\u003cli\u003eInjector programming for multi-draw, mixing, dilution, and stacked injections\u003c\/li\u003e\n\u003cli\u003eDual-zone Peltier column thermostat spanning 4°C to 110°C with ±0.05°C stability\u003c\/li\u003e\n\u003cli\u003eColumn compartment holds up to eight 100 mm or four 300 mm columns with individual heat exchangers\u003c\/li\u003e\n\u003cli\u003e1024-element diode array detector with eight simultaneous signals and 240 Hz data rate\u003c\/li\u003e\n\u003cli\u003eProgrammable 1, 2, 4, and 8 nm slit widths to balance sensitivity and spectral resolution\u003c\/li\u003e\n\u003cli\u003eRFID-tagged flow cells and lamps with Early Maintenance Feedback across every module\u003c\/li\u003e\n\u003cli\u003eShared leak-plane design with automatic pump shutdown on any internal leak\u003c\/li\u003e\n\u003cli\u003eShips with a Windows 11 workstation for instrument control and data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"article\" aria-setsize=\"34\" aria-posinset=\"33\" aria-label=\"Message 33 of 34\" tabindex=\"-1\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"article\" aria-setsize=\"34\" aria-posinset=\"34\" aria-label=\"Message 34 of 34\" tabindex=\"0\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp dir=\"ltr\"\u003eThe Agilent 1290 Infinity II HPLC System with Diode Array Detector (DAD) combines the G7104A Flexible Pump, G7167B Multisampler, G7116B Multicolumn Thermostat, and G7117B DAD into one UHPLC stack rated to 1300 bar, capable of running both conventional HPLC and ultra-high-pressure methods. Intelligent System Emulation Technology (ISET) allows methods from other LC systems to be transferred with retention times and resolution intact. The Flexible Pump delivers 0.001 to 5 mL\/min from a dual-piston, servo-controlled design with active damping, pairing low-pressure quaternary gradient formation with an integrated four-channel degasser, automatic purge valve, and active seal wash.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp dir=\"ltr\"\u003eThe Multisampler’s flow-through needle limits carryover and sample discrimination while accepting vials and microtiter plates in configurable drawers. Injections from 0.1 to 20 µL are delivered at full system pressure, with programming for multi-draw, mixing, dilution, and stacked injections. The Multicolumn Thermostat provides two independent Peltier zones from 4 °C to 110 °C (as low as 20 °C below ambient) with ±0.05 °C stability, holding up to eight 100 mm or four 300 mm columns with solvent preheating and still-air operation to minimize band broadening.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp dir=\"ltr\"\u003eThe G7117B Diode Array Detector pairs a 1024-element array with a 10 mm Max-Light cartridge flow cell, whose optofluidic waveguides pass nearly 100% of available light for a quiet, stable baseline. It spans 190 to 640 nm, records up to eight signals and full spectra at rates to 240 Hz, and offers programmable slit widths of 1, 2, 4, and 8 nm. The self-aligning, RFID-tagged cartridge cell seats without tools and carries its own usage record.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp dir=\"ltr\"\u003eAcross the stack, a shared leak-plane design stops the pump on any internal leak, and Early Maintenance Feedback tracks seal wear, pumped volume, injections, and lamp hours against user-set limits. Suited to pharmaceutical QC, method development, and high-throughput analysis, the Agilent 1290 Infinity II HPLC System with DAD delivers the pressure range, injection flexibility, and detection sensitivity modern separations require.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp dir=\"ltr\"\u003eThe Agilent 1290 Infinity II HPLC System with DAD is operated through Agilent OpenLab CDS or ChemStation software for instrument control, data acquisition, analysis, and automation.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp dir=\"ltr\"\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1290 Infinity II HPLC System w\/ DAD includes:\n\u003cul class=\"includes-list\"\u003e\n\u003cli\u003eG7104A Flexible Pump\u003c\/li\u003e\n\u003cli\u003eG7117B DAD Detector\u003c\/li\u003e\n\u003cli\u003eG7116B Multi Column Thermostat\u003c\/li\u003e\n\u003cli\u003eG7167B Multisampler\u003c\/li\u003e\n\u003cli\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\u003cli\u003eChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\u003cli\u003eCan\/Crossover Cables\u003c\/li\u003e\n\u003cli\u003eAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\u003cli\u003eSolvent Tubing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNew Stainless Steel Capillaries\u003c\/li\u003e\n\u003cli\u003e1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\u003cli\u003eWaste Tubing\u003c\/li\u003e\n\u003cli\u003eAll Power Cords\u003c\/li\u003e\n\u003cli\u003eAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAgilent 1290 Infinity II HPLC System w\/ DAD Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003ccenter\u003e\u003cstrong\u003eAgilent 1290 Infinity II HPLC G7117B DAD Detector Specifications\u003c\/strong\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeuterium lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 to 640 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Term Noise (ASTM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 3 x 10\u003csup\u003e-6\u003c\/sup\u003e AU (10 mm cell, included); \u0026lt; ± 0.6 x 10\u003csup\u003e-6\u003c\/sup\u003e AU\/cm (60 mm cell), at 230\/4 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 x 10\u003csup\u003e-3\u003c\/sup\u003e AU\/h at 230 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2.0 AU (5%) at 265 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1 nm, self-calibration with deuterium lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength Bunching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 400 nm, programmable in 1 nm steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlit Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable: 1, 2, 4, 8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiode Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~ 0.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 Hz (signals and spectra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 10 mm Max-Light cartridge cell, σV = 1.0 µL; 60 bar (870 PSI) maximum pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 x 15.6 x 17.2 in. (14.0 x 39.6 x 43.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 lb. (11.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cdiv class=\"show-hidden-table\"\u003eClick Here to View More Specifications for the Agilent 1290 Infinity II HPLC System w\/ DAD\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"hidden-table\"\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003ccenter\u003e\u003cstrong\u003eAgilent 1290 Infinity II HPLC G7104A Flexible Pump Specifications\u003c\/strong\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydraulic System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual pistons in series with servo-controlled variable stroke design and active damping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSettable Flow Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 to 5.0 mL\/min, in 0.001 mL\/min increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 0.07% RSD or 0.01 min SD, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 1% or ± 10 µL\/min, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 130 MPa (1300 bar) at 0 to 2 mL\/min; 80 MPa (800 bar) at 5 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Pulsation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1% amplitude or \u0026lt; 0.5 MPa (5 bar), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressibility Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGradient Formation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-pressure quaternary mixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelay Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAs low as 350 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComposition Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSettable range: 0 to 100%; Recommended range: 1 to 99% or 5 µL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComposition Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% RSD or 0.02 min SD, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComposition Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.4% absolute (1 to 99% B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Solvents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, expandable to a maximum of 26 with optional external solvent selection valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolvent Selection Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated 4-solvent gradient formation valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Degassing Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 channels, 1.5 mL internal volume per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Purge Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded; supports inline-filter backflush and automatic mixer change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.1 x 15.6 x 17.2 in. (18.0 x 39.6 x 43.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.5 lb. (16.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003ccenter\u003e\u003cstrong\u003eAgilent 1290 Infinity II HPLC G7167B Multisampler Specifications\u003c\/strong\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydraulic System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow-through needle design for minimized sample carryover and discrimination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 to 20 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% RSD or SD \u0026lt; 10 nL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7% (10 µL, n=10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 130 MPa (1300 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Viscosity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 5 cP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity (Configuration Dependent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6,144 samples using microtiter plates or 432 standard 2 mL vials; configurable single-, double-, and triple-height drawers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAs low as 10 seconds (single-needle configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarryover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.003% (30 ppm) without Multiwash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Programming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-draw, mixing, stacked injection, and dilution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 x 15.6 x 18.4 in. (32.0 x 39.6 x 46.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48.5 lb. (22 kg), without sample cooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003ccenter\u003e\u003cstrong\u003eAgilent 1290 Infinity II HPLC G7116B Multicolumn Thermostat Specifications\u003c\/strong\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual independent Peltier-element temperature control with solvent preheating and still-air operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4°C to 110°C (minimum 20°C below ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.5°C (with calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndependent Temperature Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in single device; up to 6 in clustered configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 columns of 100 mm length or 4 columns of 300 mm length, including Quick-Connect fittings or pre-columns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat-Up \/ Cool-Down Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 min from ambient to 40°C; 10 min from 40°C to 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolvent Heat Exchangers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually quick-installable for each column; available in 1.0 µL (ultra-low dispersion), 1.6 µL (standard), and 3 µL (high-flow) volumes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValve Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional integrated valve drive and up to 2 external valve drives; supports 2-position\/6-port, 2-position\/10-port, 6-column, and 8-column selection valve heads (up to 1300 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 x 17.1 x 17.2 in. (16.0 x 43.5 x 43.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6 lb. (12.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003ccenter\u003e\n\u003cp\u003eComputer Specifications\u003c\/p\u003e\n\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel Core i5-8500 CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.0 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHard Drive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500GB Internal SSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows 11 Professional, 64-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1290_Infinity_II_HPLC_System_w_DAD_-_Marshall_Scientific.pdf?v=1794517663\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1290_Infinity_II_LC_System_Manual_and_Quick_Reference.pdf_7056b234-c2f6-41a1-80b1-50bbfcc87944.pdf?v=1794517520\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2142.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall Scientific","offers":[{"title":"Default Title","offer_id":68059343650906,"sku":"AG-1290IIDAD","price":52725.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ca75f66b-fdaa-478f-a24c-5e437435ef5c_1.jpg?v=1794605830","url":"https:\/\/marshallscientific.com\/products\/agilent-1290-infinity-ii-hplc-system-w-dad","provider":"Marshall Scientific","version":"1.0","type":"link"}