{"product_id":"agilent-1290-infinity-ii-hplc-g7167b-multisampler","title":"Agilent 1290 Infinity II HPLC G7167B Multisampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1290 Infinity II HPLC G7167B Multisampler\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0 – 20 uL or 0 – 100 uL single stroke injection at max. pressure Up to 0.1 – 1500 uL with optional kits\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\u0026lt;0.15% RSD or SD \u0026lt;10 nL\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMaximum Pressure \u003c\/b\u003e\u003cbr\u003eUp to 1300 bar (130 MPa)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eFlow-through needle design minimizes sample carryover and discrimination for reliable chromatographic analysis\u003c\/li\u003e\n\u003cli\u003eHigh-pressure injection capability up to 1300 bar supports demanding UHPLC applications\u003c\/li\u003e\n\u003cli\u003eFlexible injection system accommodates different sample volumes and analytical requirements\u003c\/li\u003e\n\u003cli\u003eHigh-capacity sample handling supports up to 6,144 samples in microtiter plates or 432 standard 2 mL vials\u003c\/li\u003e\n\u003cli\u003eConfigurable sample drawer system accommodates microtiter plates, deep-well plates, and various vial sizes\u003c\/li\u003e\n\u003cli\u003eAutomated internal sample handling enables efficient and consistent sample processing\u003c\/li\u003e\n\u003cli\u003eFast injection cycle times as low as 10 seconds improve throughput for high-volume laboratory workflows\u003c\/li\u003e\n\u003cli\u003eAdvanced injection programming supports multi-draw, mixing, dilution, and stacked injection operations\u003c\/li\u003e\n\u003cli\u003eLow sample carryover supports accurate and reproducible analysis across demanding applications\u003c\/li\u003e\n\u003cli\u003eHigh injection precision and accuracy provide consistent sample delivery and reliable analytical results\u003c\/li\u003e\n\u003cli\u003eEarly Maintenance Feedback (EMF) continuously tracks instrument usage and provides customizable maintenance alerts\u003c\/li\u003e\n\u003cli\u003eElectronic maintenance and error records simplify troubleshooting and support dependable instrument operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/7167B_Features.jpg?v=1792775142\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Agilent 1290 Infinity II HPLC G7167B Multisampler is a high-performance autosampler designed for precise, efficient, and reliable sample handling in liquid chromatography applications. Featuring a flow-through needle design, the G7167B minimizes sample carryover and discrimination while supporting injection pressures up to 1300 bar. Its advanced injection system provides excellent precision and accuracy, making it well suited for conventional HPLC and high-pressure UHPLC workflows.\u003cbr\u003e\u003cbr\u003eThe G7167B features a flexible sample handling system capable of accommodating various sample containers, including microtiter plates and standard laboratory vials. Its automated internal robotics transport samples from the storage drawers to the injection workspace, supporting efficient and consistent sample processing. The unit is configured with vial trays for automated sample loading, while advanced injection programming supports operations such as multi-draw, mixing, dilution, and stacked injections.\u003cbr\u003e\u003cbr\u003eDesigned for dependable operation and simplified maintenance, the G7167B incorporates Early Maintenance Feedback (EMF) technology to monitor instrument usage and provide customizable maintenance alerts. Electronic maintenance and error records support troubleshooting and reliable performance across demanding analytical workflows.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003c\/p\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1290 Infinity II HPLC G7167B Multisampler includes:\n\u003cul class=\"includes-list\"\u003e\n\u003cli\u003eLatest Available Firmware Version (Please inquire)\u003c\/li\u003e\n\u003cli\u003eFront Cover\u003c\/li\u003e\n\u003cli\u003eSample Drawer\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAgilent 1290 Infinity II HPLC G7167B Multisampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 20 µL or 0 – 100 µL single stroke injection at max. pressure Up to 0.1 – 1500 µL with optional kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.15% RSD or SD \u0026lt;10 nL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7% (10 µL, n=10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1300 bar (130 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Viscosity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2–5.0 cP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6,144 samples using microtiter plates or 432 standard 2 mL vials; configurable single-, double-, and triple-height drawers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAs low as 10 seconds (single-needle configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarryover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.003% (30 ppm) without Multiwash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydraulic System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow-through needle design for minimized sample carryover and discrimination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Programming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-draw, mixing, stacked injections, and dilution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6 × 15.6 × 18.4 in. (32 × 39.6 × 46.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48.5 lb. (22 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1290_Infinity_II_HPLC_G7167B_Multisampler_-_Marshall_Scientific.pdf?v=1792775044\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1290_Infinity_II_LC_System_Manual_and_Quick_Reference.pdf.pdf?v=1792775046\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2142.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e","brand":"Marshall Scientific","offers":[{"title":"Default Title","offer_id":67826043420762,"sku":"AG-1290MS","price":19995.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/a8cf7106-327c-457a-8a13-f2345297465e_48be1706-a507-4602-84e9-54af75d1367c.jpg?v=1792775302","url":"https:\/\/marshallscientific.com\/products\/agilent-1290-infinity-ii-hplc-g7167b-multisampler","provider":"Marshall Scientific","version":"1.0","type":"link"}