{"product_id":"agilent-1260-infinity-i-hplc-system","title":"Agilent 1260 Infinity I HPLC System","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e 190 to 640 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 10 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003e0 to 600 bar (0 to 60 MPa) at 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers exceptional flexibility for solvent selection and automation in HPLC method development and research\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSuited for multi-method, high-throughput workflows with easy access to four solvents for isocratic or gradient analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a quaternary pump with a pressure capacity up to 600 bar for efficient solvent delivery\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes the 1260 Infinity Autosampler for low carryover and precise variable volume injection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with a Diode-Array Detector (DAD) with a wavelength range of 190 - 640 nm for high optical performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eControlled by Agilent ChemStation Workstation Software for easy data acquisition, analysis, and instrument control\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler offers a broad injection range and sample capacity, accommodating various sample types and volumes\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eThermostatted column compartment and ALS thermostat provide precise temperature management for retention time reproducibility\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_65d96134-6955-446a-84b8-71a73f9fdad0.jpg?v=1779985289\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\tThe Agilent 1260 Infinity I HPLC System offers \n\t\u003cspan style=\"background-color: initial;\"\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003ethe most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring \u003c\/span\u003econtinuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to four solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's quaternary pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly which can generate pressure up to 600 bar. Degassing of the solvents is done in a built-in vacuum degasser \u003c\/span\u003eintegrated\u003cspan style=\"letter-spacing: 0px;\"\u003e into the quaternary pump. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. The featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 640 nm, an 80 Hz data \u003c\/span\u003eacquisition\u003cspan style=\"letter-spacing: 0px;\"\u003e rate, and fixed 4 nm slit for rapid optimization of \u003c\/span\u003esensitivity\u003cspan style=\"letter-spacing: 0px;\"\u003e, \u003c\/span\u003elinearity\u003cspan style=\"letter-spacing: 0px;\"\u003e, and spectral resolution. \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1311B Quaternary Pump (With Built-In Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1315C DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1315C Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1311B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoNormalTable\" style=\"width:348pt; background-color: white;\" cell=\"\" padding=\"0\" width=\"464\" cellspacing=\"0\" border=\"1\"\u003e\n\t\u003c\/table\u003e\n\t\u003ctable class=\"spec-table\" border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eDAD Detector\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 640 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 3 × 10^-6 AU at 230 nm\/4 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.5 × 10^-3 AU\/hr at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLinear Absorbance Range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t ± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFixed 4 nm slit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~ 0.5 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cells\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tMax-Light Cartridge Cell (10 mm, V [σ], 1.0ul), 60 bar (870 psi) pressure maximum\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eMax-Light Cartridge Cell (60 mm, V [σ], 4.0ul), 60 bar (870 psi) pressure maximum\u003cbr\u003e\u003cbr\u003eMax-Light Cartridge Test Cell\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRecorder\/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tController-area network (CAN), GPIB, \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRS-232C, APG Remote: ready, start, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003estop and shut-down signals, LAN\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tExtensive diagnostics, error detection, and display (through control module \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eand ChemStation), leak detection, safe \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak handling, leak output signal for \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eshutdown of pumping system. Low \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003evoltages in major maintenance areas.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eusage in terms of lamp burn time with \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003euser-settable limits and feedback \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emessages. Electronic records of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emaintenance and errors. Verification of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ewavelength accuracy with built-in \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eholmium oxide filter.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAll materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable class=\"MsoTableGrid\" font-size:=\"\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eQuaternary\u003c\/b\u003e\u003cb\u003e Pump\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 10 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 10.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater based on retention time at constant ambient temperature\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min, 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSettable range: 0 - 95% or 5 - 100%\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 0.2 % RSD or \u0026lt; 0.04 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t600 - 900 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eAutosampler\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.25% from 5 - 40µl\n\t\t\t\t\u003cbr\u003e\u0026lt; 0.5% from 2 - 5µl\u003cbr\u003e\u0026lt; 0.7% from 1 - 2µl\u003cbr\u003e\u0026lt; 1.5% from 0.5 - 1µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tUp to 600 bar (8,700 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\t\u003cbr\u003e108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\u003cbr\u003e30 x 6 ml vials in 2 x 15 vial plate\u003cbr\u003e100 Micro vial tray plus 10 additional 2 ml vials\u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plates\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 21 seconds using default conditions and injection volume of 5µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eALS Thermostat\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eColumn Compartment\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable class=\"spec-table\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_-_Marshall_Scientific.pdf?v=1779985293\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_Manual_-_Marshall_Scientific.pdf?v=1779985297\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2238.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474473816154,"sku":"AG-1260HPLC","price":40095.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC-2.jpg?v=1761205124","url":"https:\/\/marshallscientific.com\/products\/agilent-1260-infinity-i-hplc-system","provider":"Marshall Scientific","version":"1.0","type":"link"}