{"product_id":"agilent-1200-hplc-g1329a-autosampler","title":"Agilent 1200 HPLC G1329A Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1200 HPLC G1329A Autosampler\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 µl in 0.1 µl increments\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 – 100 µl \u003cbr\u003eTypically \u0026lt; 1 % RSD 1 – 5 µl variable volume\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eSample Capacity \u003c\/b\u003e\u003cbr\u003e100 × 2-ml vials in 1 tray\u003cbr\u003e40 × 2-ml vials in ½ tray\u003cbr\u003e15 × 6-ml vials in ½ tray (Agilent vials only)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with GLP features, including early maintenance feedback (EMF) and electronic records of maintenance and errors\u003c\/li\u003e\n\u003cli\u003eMultiple communication options with CAN, GPIB, RS232C, and APG-remote interfaces for seamless integration\u003c\/li\u003e\n\u003cli\u003eAdvanced safety features such as leak detection, safe leak handling, and low voltage in maintenance areas\u003c\/li\u003e\n\u003cli\u003eError detection and display system for quick issue identification and resolution\u003c\/li\u003e\n\u003cli\u003eSupports 1–99 replicate injections from a single vial for enhanced workflow efficiency\u003c\/li\u003e\n\u003cli\u003eLow carryover rate, typically \u0026lt; 0.1%, further reduced to \u0026lt; 0.05% with external needle cleaning\u003c\/li\u003e\n\u003cli\u003eHandles a wide sample viscosity range from 0.2 to 50 cp for diverse sample types\u003c\/li\u003e\n\u003cli\u003eFast injection cycle time, typically 50 seconds, for increased throughput\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1329A_da9a4388-3e39-44f3-a0a9-5d1f1e617948.jpg?v=1779984731\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Agilent 1200 HPLC G1329A Autosampler is a variable volume autosampler with a sample capacity of 100 samples. The G1329A's variable volume injections range from 1 to 100 µl and are programmable and temperature controlled. The temperature ranges from 4° to 40°C with a temperature accuracy of -1° to +5°C. \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC G1329A Autosampler includes:\n\u003cul\u003e\n\u003cli\u003eLatest Available Firmware Version (Please inquire)\u003c\/li\u003e\n\u003cli\u003eOperator's Guide\u003c\/li\u003e\n\u003cli\u003e100 Vial Tray\u003c\/li\u003e\n\u003cli\u003eFront Cover\u003c\/li\u003e\n\u003cli\u003eLab Advisor Documentation\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eAgilent 1200 HPLC G1329A Autosampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eGLP Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eEarly maintenance feedback (EMF), electronic records of maintenance and errors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCommunications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eController-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSafety Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003erequired)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eReplicate Injections\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 – 99 from one vial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003ePrecision\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 – 100 µl\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 1 % RSD 1 – 5 µl variable volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eMinimum Sample Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCarryover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Viscosity Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.2 – 50 cp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eReplicate Injections Per Vial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 – 99\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e100 × 2-ml vials in 1 tray\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e40 × 2-ml vials in ½ tray\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e15 × 6-ml vials in ½ tray (Agilent vials only)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Cycle Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal; tab-stops: 53.05pt;\"\u003eTypically 50 s depending on draw speed and injection volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1200_G1329a-90012_Spec.pdf?v=1779984735\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1200G1329a-90012_StandPrepSamplers.fm.pdf?v=1779984739\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/1930.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474484269146,"sku":"AG-12g13","price":6695.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-12g13-2.jpg?v=1761205869","url":"https:\/\/marshallscientific.com\/products\/agilent-1200-hplc-g1329a-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}