{"product_id":"agilent-1200-hplc-g1315b-dad-detector","title":"Agilent 1200 HPLC G1315B DAD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1200 HPLC G1315B DAD Detector\u003c\/h1\u003e\n\u003cbr\u003eThe Agilent 1200 HPLC G1315B DAD Detector verifies separation quality with peak purity, multiple signals, and spectral libraries during analytical quantification, offering an extended wavelength range with the highest sensitivity. The diode array detector allows for automated wavelength verification for performance tracking. The Agilent 1200’s temperature management system ensures optimum baseline stability, even under rough ambient conditions. This detector features superb illumination using combined deuterium and tungsten lamps for the highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution. The programmable slit helps you explore the spectral landscape for faster sample characterization, ensuring higher sensitivity or lower baseline noise as necessary on the 1100. Slit settings can be stored and reported from 1 – 16 nm with raw data for GLP traceability. \u003cbr\u003e\u003cbr\u003eAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1200 HPLC G1315B DAD Detector includes:\n\u003cul\u003e\n\u003cli\u003eLatest Available Firmware Version (Please inquire)\u003c\/li\u003e\n\u003cli\u003eFlow Cell\u003c\/li\u003e\n\u003cli\u003eTungsten and Deuterium Lamps\u003c\/li\u003e\n\u003cli\u003eLab Advisor Calibration Report\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eOperator's Guide\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eAgilent 1200 HPLC G1315B DAD Detector Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDetection Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 - 950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Noise (ASTM) Single and Multi-Wavelength\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; ± 1 x 10 \u003csup\u003e-5\u003c\/sup\u003e AU, at 254 and 750 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e2 x 10 \u003csup\u003e-3\u003c\/sup\u003e AU\/h at 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Absorbance Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2 AU (upper limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Bunching\u003c\/td\u003e\n\u003ctd\u003e1 - 400 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Width\u003c\/td\u003e\n\u003ctd\u003e1, 2, 4, 8, 16 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Width\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cell\u003c\/td\u003e\n\u003ctd\u003eStandard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl and Data Evaluation\u003c\/td\u003e\n\u003ctd\u003eAgilent ChemStation for LC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e13.5 x 17 x 5.5 in. (34.5 x 43.5 x 14 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e26 lb. (11.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e100-240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_HPLC_G1315B_DAD_Detector_-_Marshall_Scientific.pdf?v=1779984663\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1200_HPLC_G1315B_DAD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779984668\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2345.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474505273434,"sku":"AG-DAD1200B","price":7995.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1200B-2.jpg?v=1761207505","url":"https:\/\/marshallscientific.com\/products\/agilent-1200-hplc-g1315b-dad-detector","provider":"Marshall Scientific","version":"1.0","type":"link"}