{"product_id":"agilent-1100-hplc-system-w-vwd-fld-detectors","title":"Agilent 1100 HPLC System w\/VWD \u0026 FLD Detectors","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1100 HPLC System with Variable Wavelength Detector \u0026amp; Fluorescence Detector\u003c\/h1\u003e\n\t\u003cbr\u003eThe Agilent 1100 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1100 both remarkably easy-to-use and maintenance-free. It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance. \u003cbr\u003e\u003cbr\u003eThe Agilent 1100 Variable Wavelength Detector lowers detection limits with simplified optics for high sensitivity, low baseline drift, and wide linear range. This wide linear range allows for reliable simultaneous quantitation of main and side products and impurities. The Agilent 1100 VWD’s minimum baseline noise gives it the highest baseline stability for the lowest detection limits. This VWD offers programmable wavelength switching for sensitivity and optimized selectivity optimized to each analyte’s elution, along with stop-flow wavelength scanning for quick wavelength optimization. \u003cbr\u003e\u003cbr\u003eThe Agilent 1100 Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.\u003cbr\u003e\u003cbr\u003eThe unit can be operated with a hand-held controller or computer running Clarity software. The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cp class=\"MsoNormal\" style=\"letter-spacing: normal;\"\u003e\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1100 HPLC System w\/VWD \u0026amp; FLD Detectors includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1311A Quat Pump (Binary Pump Available)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329A Thermal Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Therm\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1314A VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1321A FLD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A Column Compartment \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1379A Degasser\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 10 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemstation version 4.3 software installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent G1369 Lan Interface Card\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nStainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1314A Variable Wavelength Detector \u0026amp; G1321A Fluorescence Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1311A Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329A Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1100 HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003ch2\u003eAgilent 1100 HPLC System Specifications\u003c\/h2\u003e\n\t\u003cbr\u003e\n\t\u003ctable border=\"1\" style=\"font-size: 14.44444465637207px;\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eType\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nDetection type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nShort term noise (ASTM) Single \n\t\t\t\u003cbr\u003eand Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n± 0.75 × 10-5AU at 254 nm\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n3 × 10-4AU\/hr at 254 nm\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nLinear Absorbance range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\u0026gt; 2 AU (5%) upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nWavelength accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nSlit width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n1, 2, 4 , 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nBand Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n6.5 nm typical\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nStandard: 14-µl volume, 10-mm \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\ncell path length and 40 bar \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n(588 psi) pressure maximum\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nHigh pressure: 14-µl volume,\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n10-mm cell path length and \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n400 bar (5880 psi) pressure \n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nmaximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eRecorder\/integrator: 100 mV or 1 V,\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\noutput range 0.001 – 2 AU, two\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\noutputs\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nController-area network (CAN), GPIB,\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nRS-232C, APG Remote: ready, start,\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nstop and shut-down signals, LAN\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eoptional\u003c\/span\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eExtensive diagnostics, error detection\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nand display (through control module\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nand ChemStation), leak detection, safe\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nleak handling, leak output signal for\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nshutdown of pumping system. Low\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nvoltages in major maintenance areas.\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan style=\"font-size: 14px; background-color: initial;\"\u003eEarly maintenance feedback (EMF) for\u003c\/span\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\ncontinuous tracking of instrument\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nusage in terms of lamp burn time with\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nuser-settable limits and feedback\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nmessages. Electronic records of\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nmaintenance and errors. Verification of\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nwavelength accuracy with built-in\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\nholmium oxide filter.\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nAll Materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" style=\"background-color: rgb(255, 255, 255); font-size: 16px;\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"623\" colspan=\"2\" valign=\"top\" style=\"border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt; width: 467.5pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: 0.0001pt; line-height: normal; text-align: center;\"\u003e\n\t\t\t\tComputer Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left-width: 1pt; border-left-color: windowtext; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tModel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tDell Optiplex 7050 Desktop PC\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left-width: 1pt; border-left-color: windowtext; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tIntel Core i5-6500 Processor 3.6GHz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left-width: 1pt; border-left-color: windowtext; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tRam\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t16GB\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left-width: 1pt; border-left-color: windowtext; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t250GB Internal SSD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left-width: 1pt; border-left-color: windowtext; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"312\" valign=\"top\" style=\"border-top: none; border-right-width: 1pt; border-right-color: windowtext; border-bottom-width: 1pt; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt; width: 233.75pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\tWindows 10 Professional, 64bit\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Ag1100VWDFLDsystem_specs_0a182f80-f288-4ead-a772-03cbd7ed62c9.pdf?v=1779984611\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1100-manual.pdf?v=1779984600\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Ag1100VWDFLDsystem_specs_0a182f80-f288-4ead-a772-03cbd7ed62c9.pdf?v=1779984611\" target=\"blank\"\u003e\n\t\u003c\/a\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/429.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474448224346,"sku":"AG-1100SS","price":18995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1100SS-2.jpg?v=1761204557","url":"https:\/\/marshallscientific.com\/products\/agilent-1100-hplc-system-w-vwd-fld-detectors","provider":"Marshall Scientific","version":"1.0","type":"link"}