{"product_id":"agilent-1100-hplc-g1367a-autosampler","title":"Agilent 1100 HPLC G1367A Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1100 HPLC G1367A Autosampler\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 µl in 0.1 µl increments\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 – 100 µl\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eSample Capacity \u003c\/b\u003e\u003cbr\u003e2 × well-plates (MTP) + 10 × 2 ml vials\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for high-throughput HPLC applications requiring fast injection cycles\u003c\/li\u003e\n\u003cli\u003eTypical injection cycle time under 30 seconds for efficient sample processing\u003c\/li\u003e\n\u003cli\u003eExtremely low carry-over—typically less than 0.01%—for reliable trace analysis\u003c\/li\u003e\n\u003cli\u003eSupports a sample viscosity range of 0.2 to 5 cP for versatile sample compatibility\u003c\/li\u003e\n\u003cli\u003eAdvanced safety features including leak detection, safe leak handling, and low-voltage maintenance zones\u003c\/li\u003e\n\u003cli\u003eGLP-compliant with electronic maintenance tracking and error logging\u003c\/li\u003e\n\u003cli\u003eMultiple communication options including CAN, RS-232C, APG Remote, and optional contact closures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-ALAAS-3T_2d50edfa-1b14-49b9-a22d-28f50aa98b95.jpg?v=1779984565\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe Agilent 1100 G1367A Autosampler adds maximum flexibility and fast injection cycles to your Agilent HPLC system. Whenever high sample throughput and speed of analysis are points to consider, the G1367A is the autosampler to choose.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1100 HPLC G1367A Autosampler includes:\n\u003cul\u003e\n\u003cli\u003eLatest Available Firmware Version (Please inquire)\u003c\/li\u003e\n\u003cli\u003eVial Tray (Please Inquire for Well Plate Tray)\u003c\/li\u003e\n\u003cli\u003eLab Advisor Documentation\u003c\/li\u003e\n\u003cli\u003eLan Cable \/ Power Cord\u003c\/li\u003e\n\u003cli\u003eOperator's Manual\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eAgilent 1100 HPLC G1367A Autosampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eGLP Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eEarly maintainece feedback (EMF), electronic records of maintainence and errors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCommunications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eController-area network (CAN). RS232C, APG remote standard, optional four external contact closures and BCD vial number output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSafety Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eLeak detection and safe leak handling, low voltages in maintence areas, error detection and display\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003ePrecision\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 – 100 µl, Typically \u0026lt; 1 % RSD from 1 – 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Viscosity Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.2 – 5 cp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e2 × well-plates (MTP) + 10 × 2 ml vials [Not Included] \u003cbr\u003e\u003cbr\u003e100 x 2 ml in one tray 40 x 2 ml in half tray [Included]\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Cycle Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 30 s using following standard conditions: Default draw speed: 200 µl\/min Default eject speed: 200 µl\/min Injection volume: 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top-style: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCarry-Over\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"312\" valign=\"top\" style=\"width: 233.75pt; border-top-style: none; border-left-style: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: Water\/Acetonitrile = 80\/20 Flow rate: 1 ml\/min Injection volume: 1 µl caffeine (1 mg\/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1329A_manual.pdf?v=1779984571\" target=\"_blank\"\u003eAgilent 1100 G1367A Manual\u003c\/a\u003e\u003ccenter\u003e\u003cbr\u003e\u003c\/center\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1367A_specs_c39d0c43-1535-4815-a5f5-77c3068f75a0.pdf?v=1779984577\"\u003e\u003cimg\u003eClick Here to View all the Technical Specs for the G1367A Autosampler\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/516.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474497638490,"sku":"AG-ALAAS","price":4295.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-ALAAS-2.jpg?v=1761207110","url":"https:\/\/marshallscientific.com\/products\/agilent-1100-hplc-g1367a-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}