{"product_id":"agilent-1100-hplc-g1361a-preparative-pump","title":"Agilent 1100 HPLC G1361A Preparative Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1100 HPLC G1361A Preparative Pump\u003c\/h1\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1100 HPLC G1361A Preparative Pump is an isocratic high-performance pump with two parallel pistons, perfect for scale-up work, for typical preparative HPLC and for purity checks. This is a cam driven pump, with fixed stroke and two parallel pistons, each with (identical ball and seat) inlet and outlet valve. Each of the two pump pistons can deliver a maximum of 50 ml\/min flow at up to 400 bar pressure. The two cams have overlapping delivery cycles. Compression losses are calculated, and smooth delivery is ensured through variation of the motor speed over the pump cycle. The pistons are guided through two seals each. The gap between those seals is connected to capillary fittings, this way seal wash is not only an option, but an integral part of every pump. A peristaltic pump, to automate seal wash, is also part of the system. \n\t\u003cbr\u003e\u003cbr\u003eThe pump flow leaving the pump head passes through the multi-assembly, which combines the flow of the two pistons, filters the solvent and contains a pressure sensor to monitor system pressure. No hydraulic damper is included in the system. This makes very fast gradients possible. From the multi-assembly the flow is routed to the purge valve and from there either directly into waste or on to the next module (normally injection valve or sampling device). Gradients are formed with two combined pumps, as high-pressure gradients. The combined flow is flowing through a passive mixer, to smooth composition. With its high-pressure mixing principle gradient systems and the usually high flow rates, no degassing of solvents is necessary.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1100 HPLC G1361A Preparative Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\n Firmware Version 06.50 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Leak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1100 HPLC G1361A Preparative Pump Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"spec-table\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual pistons in parallel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.001 - 100 mL\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.5% RSD\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t20 to 400 bar (5880 psi) system pressure\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tControl\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAgilent ChemStation for LC and LC\/MS\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tController-area network (CAN), RS-232, APG Remote: ready, start, stop and shut-down signals, CAN-DC OUT, LAN optional\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tExtensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAll materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8 x 13.5 x 18 in. (20 x 34.5 x 44 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t34 lb. (15 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100 - 240V, 50\/60Hz, 210W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1100___1200_HPLC_G1361A_Preparative_Pump_-_Marshall_Scientific.pdf?v=1779984534\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1100___1200_HPLC_G1361A_Preparative_Pump_Manual_-_Marshall_Scientific.pdf?v=1779984538\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2438.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474447929434,"sku":"AG-1100PP","price":4995.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1100PP-2.jpg?v=1761204534","url":"https:\/\/marshallscientific.com\/products\/agilent-1100-hplc-g1361a-preparative-pump","provider":"Marshall Scientific","version":"1.0","type":"link"}