{"product_id":"agilent-1100-hplc-g1313a-autosampler","title":"Agilent 1100 HPLC G1313A Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1100 HPLC G1313A Autosampler\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 to 100 µl\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003ePrecision \u003c\/b\u003e\u003cbr\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 to 100 µl\u003cbr\u003eTypically \u0026lt; 1 % RSD of peak areas from 1 to 5 µl\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eMinimum Sample Volume \u003c\/b\u003e\u003cbr\u003e1 µl from 5 µl sample\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eGLP features include early maintenance feedback and electronic maintenance records\u003c\/li\u003e\n\u003cli\u003eLeak detection with safe handling and error display for enhanced safety\u003c\/li\u003e\n\u003cli\u003eSupports replicate injections from 1 to 99 per vial\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of sample viscosities from 0.2 to 50 cp\u003c\/li\u003e\n\u003cli\u003eInjection cycle time typically 50 seconds depending on parameters\u003c\/li\u003e\n\u003cli\u003eSample capacity of up to 100 × 2-mL vials in a standard tray\u003c\/li\u003e\n\u003cli\u003eController-area network (CAN), GPIB, and RS232C communication support\u003c\/li\u003e\n\u003cli\u003eLow internal volume (300 µL) minimizes system contribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1313A-1_137d9887-a9cf-46f6-9dac-d634a18802a2.jpg?v=1779984431\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe recertified Agilent 1100 G1313A Autosampler is designed for the reliability, safety, and ease of use needed in pharmaceutical routine tasks and quality control, as well as for environmental and food analyses. The G1313A features reliable injections from 0.1 µL to 100 µL with easy adaption for injection volumes up to 1500 µL for applications ranging from microbore to semipreparative chromatography. The Agilent 1100 G1313A's low internal volume of 300 µL allows minimum contribution to a system's total internal volume. The system uses overlapped injections for increased productivity with sample capacities of 100 × 2-mL vials in a standard tray, 40 × 2-mL vials in a standard tray, or 15 × 6-mL vials in a half tray.\u003cbr\u003e\u003cbr\u003eThe Agilent G1313A is in excellent condition and will be fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1100 HPLC G1313A Autosampler includes:\n\u003cul\u003e\n\u003cli\u003eLatest Available Firmware Version (Please inquire)\u003c\/li\u003e\n\u003cli\u003e100 Vial Tray\u003c\/li\u003e\n\u003cli\u003eFront Cover\u003c\/li\u003e\n\u003cli\u003eLab Advisor Diagnostic Report\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eOperator’s Guide\u003c\/li\u003e\n\u003cli\u003eFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eAgilent 1100 HPLC G1313A Autosampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eGLP Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eEarly maintenance feedback (EMF), electronic records of maintenance and errors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCommunications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eController-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSafety Features\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eReplicate Injections\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 – 99 from one vial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003ePrecision\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.5 % RSD of peak areas from 5 – 100 µl\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 1 % RSD of peak areas from 1 – 5 µl\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eMinimum Sample Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eCarryover\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Viscosity Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e0.2 – 50 cp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eReplicate Injections Per Vial\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e1 – 99\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eSample Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e100 × 2-ml vials in 1 tray\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e40 × 2-ml vials in ½ tray\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e15 × 6-ml vials in ½ tray (Agilent vials only)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003eInjection Cycle Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal; tab-stops: 53.05pt;\"\u003eTypically 50 s depending on draw speed and injection volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/g1313a_60d8e35b-ae66-4093-9a1d-a42b04f4ae8a.pdf?v=1779984434\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1100_reference_manual_g1313a.pdf?v=1779984439\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/444.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474497736794,"sku":"AG-ALSA","price":3730.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-ALSA-2.jpg?v=1761207152","url":"https:\/\/marshallscientific.com\/products\/agilent-1100-hplc-g1313a-autosampler","provider":"Marshall Scientific","version":"1.0","type":"link"}