{"title":"Agilent 1260 Infinity HPLC Systems and Components","description":"","products":[{"product_id":"agilent-1260-infinity-i-hplc-g1364c-analytical-scale-fraction-collector","title":"Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector\u003c\/h1\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector is optimized for laboratories performing analytical-scale compound purification of nanogram to milligram quantities with typical flow rates between 0.1 and 10 mL\/min. The module features the full set of collection modes and is compatible with a wide variety of trigger sources. SBS plates and four different tube sizes with various lengths are supported. Equipped with a 3\/2 diverter valve featuring a low internal volume of 15 ul and a quick switching time under 100 ms, it ensures minimal delay and high precision.\u003cbr\u003e\u003cbr\u003eThe Analytical-Scale Fraction Collector's maximum capacity can easily be enhanced by clustering up to three modules simultaneously through a 12-position, 13-port selector valve. Additionally, it offers cooling options when paired with the G1330B for enhanced performance, depending on the collected fraction's volume and ambient conditions. Its delay calibration is managed by a single wavelength absorbance detector operating at 654 nm, ensuring accurate and reliable operation. This model supports multiple trigger modes such as time slices, peak detection, timetable, and manual triggers, making it a flexible choice for a variety of laboratory settings.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nMTP Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nDelay Volume Detection and Lab Advisor Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1364C Analytical-Scale Fraction Collector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDelay Volume (in ul)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiverter valve: ~15\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiverter valve to needle: ~10\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNeedle: ~4\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum System Flow\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 mL\/min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve). The analytical scale fraction collector can be modified for flow rates \u0026gt; 10 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Collection Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t~20 mL with 48 mm tubes\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t~30 mL with 75 mm tubes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve (PN G1160A)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCooling\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTrigger Modes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTime slices\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPeak (threshold, up- \/ downslope)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable (combination of time intervals and peak)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tManual trigger (supported only with Agilent Instant Pilot G4208A)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTrigger Sources\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAgilent 1260 Infinity DAD\/MWD detectors (G1315C,D; G4212B\/ G1365 C,D), the Agilent 1260 Infinity Fluorescence Detector (G1321A) and the Agilent G1946C\/D, G1956A\/B LC-MSD are fully supported\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOperating Modes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDiscrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tContinuous flow: optional, available only when using deep well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNeedle into location: Needle pushes into the vessel as deep as specified, for the use with capped vials and test tubes and well plates with closing mats\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDroplet setup mode: The tip of the fraction collector needle will initially move down to the bottom of the well. Then it will slowly move upwards while the fraction is collected. The droplet setup mode enables the fraction collector to collect small fractions without bubbles\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiverter Valve\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3\/2 valve, with switching time \u0026lt; 100 ms\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Pressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6 bar at the diverter valve during switching\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPlates\/Trays\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t4 x well-plates full tray (MTP)*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 x well-plates std. tray + 10 funnels with external containers* (+ 1 half tray)\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 × well-plates std. tray (MTP) + 10 × 2 ml vials* (+ 1 half tray)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 x 2 ml in std. tray (+ 1 half tray)*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 40 x 2 ml in half tray*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 40 funnels in half tray\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3 x 15 x 6 ml in half tray*\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 40 test tubes (30 mm OD, max. height 48 mm, ~20 ml vol.)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 60 test tubes (25 mm OD, max. height 48 mm\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 126 test tubes (16 mm OD, max. height 48 mm)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFull tray with 215 test tubes (12 mm OD, max. height 48 mm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Tube Height\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t48 mm with long needle assembly G1367-87200\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t75 mm with short needle assembly G1364-87202\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDelay Calibration Sensor\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiverter Valve\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3\/2 Diverter Valve with low internal volume (15 ul), switching time \u0026lt; 100 ms, maximum operating pressure 6 bar\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8 x 13.5 x 17 in. (20 x 34.5 x 44 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t29.8 lb. (13.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 200VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1364C_Analytical-Scale_Fraction_Collector_-_Marshall_Scientific.pdf?v=1779985230\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G1364F_Analytical-Scale_Fraction_Collector_Manual_-_Marshall_Scientific.pdf?v=1779985234\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2809.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474461069402,"sku":"AG-126064C","price":8550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-126064C-2.jpg?v=1761204905"},{"product_id":"agilent-1260-infinity-i-hplc-g1329b-autosampler","title":"Agilent 1260 Infinity I HPLC G1329B Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1329B Autosampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0 - 60 Mpa\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eTransport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEarly maintenance feedback (EMF), electronic records of maintenance and errors.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eThe autosampler continuous flow-through design ensures that sample loop, needle inside, seat capillary, and the mainpass of the injection valve is always in the flow line.\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1329B_-_Marshall_Scientific.jpg?v=1779985203\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1329B Autosampler is designed to offer the well-established flow-through design with variable volume injection and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and precision. This autosampler features a sample capacity of up to 100 samples. The 1260 Infinity G1329B Autosampler is designed for use with other modules of the Agilent 1200 Infinity Series, 1200 Series, or 1100 Series LC, or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled by the Agilent Instant Pilot or by Agilent control software\u003cbr\u003e\u003cbr\u003eThe G1329B's transport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return. A gripper arm picks up the vials and positions them below the sampling unit. Movement is also monitored by optical sensors and optical encoders to ensure correct operation. The metering device is always flushed after injection to ensure minimum carry-over. The standard analytical head of the metering device provides injection volumes from 0.1 to 100 µl, and can be operated up to 600 bar. For applications that require temperature control, this module can be paired with the Agilent 1290 Infinity Thermostat (G1330B). \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1329B Autosampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n100 Vial Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1329B Autosampler Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nGLP Features\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nEarly maintenance feedback (EMF), electronic records of maintenance\nand errors\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nCommunications\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nController-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSafety Features\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nLeak detection and safe leak handling, low voltages in maintenance\nareas, error detection and display\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nInjection Range\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n0.1 – 100 µl in 0.1 µl increments (recommended 1 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl increments)\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tUp to 1500 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl with multiple draw (hardware modification required)\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nReplicate Injections\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n1 – 99 from one vial\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nPrecision\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 0.25 % RSD of peak areas from 5 to 100 µl\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 1 % RSD of peak areas from 1 to 5 µl\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nMinimum Sample Volume\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample\nin 300 µl microvial\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nCarryover\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSample Viscosity Range\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n0.2 – 50 cp\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tMetering Devices\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tMetering pump in high pressure flow path\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nSample Capacity\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n100 × 2 ml vials in 1 tray\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n40 × 2 ml vials in ½ tray\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n15 × 6 ml vials in ½ tray (Agilent vials only)\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\nInjection Cycle Time\n\t\t\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal;tab-stops:53.05pt\"\u003e\n\t\t\t\t50 seconds for draw speed 200 \n\t\t\t\t\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\/min, ejection speed 200 \u003c\/span\u003e\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\/min, injection volume 5 \u003c\/span\u003e\u003cspan style=\"background-color: initial; font-size: 1em;\"\u003eµl\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t0 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t8 x 13.5 x 17 in (20 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"199\" valign=\"top\" style=\"width: 149.4pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"439\" valign=\"top\" style=\"width: 329.4pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t32 lb. (14.2 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1329B_Autosampler_-_Marshall_Scientific.pdf?v=1779985206\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1329B_Autosampler_Manual_-_Marshall_Scientific.pdf?v=1779985211\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2341.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474463166554,"sku":"AG-1260ALS","price":8495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALS-2.jpg?v=1761204932"},{"product_id":"agilent-1260-infinity-i-hplc-g1367e-high-performance-autosampler","title":"Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1367E High Performance Autosampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e\t\n0.1 – 100 µL in 0.1 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t\u0026lt; 0.25 % from 5 – 40 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8700 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eHigh-speed X-Z-theta robotic arm for fast and accurate sample positioning\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlow-through design minimizes carryover and supports high sample throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOverlapped injection mode increases productivity in high-throughput environments\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with a wide range of sample containers, including vials, well plates, Eppendorf tubes, and microvial trays\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFast injection cycle time of under 21 seconds for improved efficiency\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eNeedle flush station with peristaltic pump reduces carryover for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in leak detection and safe waste management for enhanced operational safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEarly maintenance feedback (EMF) system tracks component usage and service needs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAdvanced diagnostics and error detection for reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional temperature control via external thermostat module for sample stability\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALSE_377be630-79c0-4b63-a991-8f02250e6bc8.jpg?v=1779985255\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler is designed for fast, precise, and flexible sample injection in high-throughput HPLC workflows. Supporting pressures up to 600 bar, it seamlessly integrates with modern narrow-bore columns and binary LC systems to boost productivity. With an injection range from 0.1 to 100 µL and exceptional precision even at low volumes, this autosampler enables reliable analysis across a wide range of sample types and volumes.\n\t\u003cbr\u003e\u003cbr\u003e\n\tEngineered with a robust X-Z-theta robotic arm, high-speed injection valve, and low carryover flow-through design, the G1367E delivers high repeatability and minimal downtime. Built-in early maintenance feedback (EMF), leak detection, and advanced diagnostics enhance operational reliability. Sample capacity is highly flexible, accommodating well plates, vials, Eppendorf tubes, and microvial trays, with fast injection cycles of under 21 seconds. A needle flush station minimizes carryover, while optional thermostatted modules ensure precise vial\/plate temperature control for sensitive workflows. This high-performance autosampler is ideal for demanding labs requiring efficiency, precision, and scalability.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1367E High Performance Autosampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nMTP Tray\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1367E High Performance Autosampler Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tOperating range 0 - 60 MPa (0 - 600 bar, 0 - 8700 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEarly maintenance feedback (EMF), electronic records of maintenance and errors\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nController-area network (CAN), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\nSafety Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\nLeak detection and safe leak handling, low voltages in maintenance areas, error detection and display\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.1 – 100 µL in 0.1 µL increments (recommended 1 µl increments)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 40 µL with reduced injection volume kit (hardware modification required)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 1500 µl with multiple draw (hardware modification required)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.25 % from 5 – 40 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.5 % from 2 – 5 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 0.7 % from 1 – 2 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; 1.5 % from 0.5 – 1 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.2 – 5 cp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMetering Devices\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMetering pump in high pressure flow path\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t30 x 6 ml vials in 2 x 15 vial plate\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 Micro vial tray\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 21 s using default conditions and injections volume of 5 µL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8 x 13.5 x 17 in (20 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t35 lb. (15.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1367E_High_Performance_Autosampler_-_Marshall_Scientific.pdf?v=1779985259\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1367E_High_Performance_Autosampler_Manual_-_Marshall_Scientific.pdf?v=1779985264\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2906.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474465919066,"sku":"AG-1260ALSE","price":8550.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260ALSE-2.jpg?v=1761204962"},{"product_id":"agilent-1260-infinity-ii-hplc-g7112b-binary-pump","title":"Agilent 1260 Infinity II HPLC G7112B Binary Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7112B Binary Pump\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSettable Flow Range\u003c\/b\u003e\u003cbr\u003e\t0.001 - 5.0 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRecommended Flow Range\u003c\/b\u003e\u003cbr\u003e0.05 - 5.0 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Precision\u003c\/b\u003e\u003cbr\u003e\t≤ 0.07% RSD or ≤ 0.02 min SD, whichever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eTwo dual-piston in-series pumps with servo-controlled variable stroke drive\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePressure operating range up to 60 MPa (600 bar, 8700 psi)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePre-defined compressibility compensation based on mobile phase properties\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-pressure binary gradient formation for precise solvent mixing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAdjustable delay volume between 600 - 900 µl depending on back pressure\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptimized solvent delivery system ensures consistent and reproducible flow rates\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRecommended pH range of 1.0 - 12.5 with compatibility for stainless steel-compatible solvents\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260BINII-3_c8f05c53-d2fe-4196-bf1e-6ff2e55db03f.jpg?v=1779985371\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7112B Binary Pump is designed for high-performance liquid chromatography applications, delivering precise and reliable solvent delivery. With an operating pressure of up to 600 bar and a flow range of 0.001 to 5.0 mL\/min, it supports conventional, superficially porous particle, and STM column technologies. The pump employs a two-channel, dual-piston in-series design for robust gradient formation via high-pressure mixing, ensuring accurate and reproducible gradients.\u003cbr\u003e\u003cbr\u003eEquipped with a two-channel integrated degasser (0.45 mL per channel), it offers exceptional flow stability, particularly at low flow rates, enhancing detector sensitivity. Key features include user-configurable standard or low delay volumes, a bypassable pulse damper and mixer for low flowrate applications, and a pressure sensor for continuous monitoring. Ideal for high-throughput and fast-gradient methods, the pump delivers unmatched speed and resolution for routine applications with UV or MS detection, ensuring uncompromised data quality.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7112B Binary Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLeak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7112B Binary Pump Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.001 - 5.0 ml\/min, in 0.001 ml\/min increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.05 - 5.0 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.3%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tHigh-pressure binary mixing\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable Composition Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 - 100%\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended Compostion Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 99% or 5µl\/min per channel, whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIntegrated Degassing Unit\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNumber of channels: 2\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInternal volume per channel: 0.45 ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t7.1 x 15.6 x 17.2 in. (18 x 39.6 x 43.6 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t38.8 lb. (17.6 kg)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100-240V, 50\/60Hz, 90 VA\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7112B_Binary_Pump_-_Marshall_Scientific.pdf?v=1779985375\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7112B_Binary_Pump_Manual_-_Marshall_Scientific.pdf?v=1779985379\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2810.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474469851226,"sku":"AG-1260BINII","price":8450.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260BINII-2.jpg?v=1761205020"},{"product_id":"agilent-1260-infinity-ii-hplc-g7122a-degasser","title":"Agilent 1260 Infinity II HPLC G7122A Degasser","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7122A Degasser\u003c\/h1\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7122A Degasser features a sophisticated four-channel vacuum system designed to efficiently remove dissolved gases from solvents, enhancing chromatography performance. Each channel, equipped with a vacuum pump and tubular plastic membranes, operates at a maximum flow rate of 10 ml\/min, with an internal volume of 12 ml per channel. The system's operation begins when the vacuum pump is activated, creating a partial vacuum in the container as solvents pass through the membranes, ensuring almost complete degasification by the time they exit the degasser.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis degasser is designed for handling solvents across a pH range of 1 to 14, making it a durable choice for high-throughput laboratories. The design focuses on maintaining a constant vacuum level, which prevents liquid from permeating but allows gases to escape, significantly reducing baseline noise and quenching effects. This is particularly beneficial in applications requiring high sensitivity, such as fluorescence detection in gel permeation chromatography (GPC) and size exclusion chromatography (SEC), where it delivers lower detection limits and sustained baseline stability. The Agilent 1260 Infinity II Degasser is highly recommended for its powerful degassing capacity and its contribution to reliable, high-quality analytical results.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7122A Degasser includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7122A Degasser Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 ml\/min per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInternal Volume per Channel\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t12 ml per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaterials in Contact with Solvent\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tPTFE, PEEK\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 14\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.2 x 15.6 x 17.2 in. (8 x 39.6 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t15.4 lb. (7 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 5W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7122A_Degasser_-_Marshall_Scientific.pdf?v=1779985436\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7122A_Degasser_Manual_-_Marshall_Scientific.pdf?v=1779985440\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2788.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474471981146,"sku":"AG-1260DGII","price":3395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260DGII-2.jpg?v=1761205044"},{"product_id":"agilent-1260-infinity-i-hplc-g1321b-fld-detector","title":"Agilent 1260 Infinity I HPLC G1321B FLD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1321B FLD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e Multi-Signal Fluorescence w\/ Rapid On-Line Scanning and Spectral Data Analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eLight Source\u003c\/b\u003e\u003cbr\u003e\t\nXenon Flash Lamp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eStandard Flow Cell \u003c\/b\u003e\u003cbr\u003e8 µl volume and 20 bar\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eSimultaneous multi-wavelength detection enables efficient data collection and analysis in a single run\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTimetable programming allows control of up to four signal wavelengths with customizable response times and spectral parameters\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-speed spectrum acquisition with scan speeds of 28 ms per data point for rapid analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in wavelength accuracy verification ensures consistent and reliable performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEasy maintenance with front access for quick component replacement\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompact and lightweight design (7 x 13.5 x 17 in., 26 lb.) for easy integration into lab setups\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eGLP-compliant design supports laboratory quality standards and operational safety\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptional cuvette accessory available for off-line spectroscopic measurements\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLD-3_4932f330-c8d0-4a28-98d4-67132535864c.jpg?v=1779985177\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe Agilent 1260 Infinity I HPLC G1321B FLD Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The G1321B is also designed for the highest optical performance, GLP compliance, and easy maintenance. Some of the features of the G1321B FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements.\n\t\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/p\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1321B FLD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n 8μl Flow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1321B FLD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPerformance Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSingle wavelength operation: • RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLight source\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPulse frequency\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t296 Hz for single signal mode 74 Hz for economy mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tReference System:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tin-line excitation measurement\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable programing\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSpectrum acquisition:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWavelength characteristic\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRepeatability+\/- 0.2 nm Accuracy+\/- 3 nm setting\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow cells\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t7 x 13.5 x 17 in. (14 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26 lb. (11.5 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1321B_FLD_Detector_-_Marshall_Scientific.pdf?v=1779985180\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1321B_FLD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985185\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2413.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474472013914,"sku":"AG-1260FLD","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLD-2.jpg?v=1761205072"},{"product_id":"agilent-1260-infinity-i-hplc-g4225a-hip-degasser","title":"Agilent 1260 Infinity I HPLC G4225A HiP Degasser","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G4225A HiP Degasser\u003c\/h1\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G4225A HiP Degasser features an advanced degassing system with four separate vacuum chambers, each fitted with semipermeable tubings. This system integrates a vacuum pump and a control assembly that activates the pump, creating a low-pressure environment in the chambers, effectively measured by an integrated pressure sensor. The setup ensures efficient solvent degassing by drawing solvents through the tubings, allowing any dissolved gases to permeate out before the solvents exit the degasser. This model supports a maximum flow rate of 0 to 10 ml\/min per channel, accommodates up to four channels, and has an internal volume of 0.45 ml per channel. Constructed with materials like TFE\/PDD Copolymer, FEP, and PEEK, it is compatible with solvents within a pH range of 1 to 14, ensuring durability and broad chemical resistance.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G4225A HiP Degasser includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G4225A HiP Degasser Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 to 10 ml\/min per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInternal Volume per Channel\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.45 ml per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaterials in Contact with Solvent\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTFE\/PDD Copolymer, FEP, PEEK\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 14\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3.1 x 13.5 x 17 in. (8 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t11 lb. (5 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G4225A_HiP_Degasser_-_Marshall_Scientific.pdf?v=1779985281\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G4225A_HiP_Degasser_Manual_-_Marshall_Scientific.pdf?v=1779985285\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2755.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474472144986,"sku":"AG-1260HIPD","price":3195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HIPD-2.jpg?v=1761205097"},{"product_id":"agilent-1260-infinity-i-hplc-system-w-dad","title":"Agilent 1260 Infinity I HPLC System w\/ DAD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System w\/ DAD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 to 640 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range (FLD)\u003c\/b\u003e\u003cbr\u003e0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 10 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers flexibility for solvent selection and automation in HPLC method development and high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a vacuum degasser integrated into the pump for efficient degassing of solvents\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eQuaternary pump accommodates a wide range of solvent compatibilities and mixing capabilities for diverse HPLC applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler designed with a flow-through needle for low carryover and high-speed sample processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit widths in DAD allow for rapid optimization of detection sensitivity and spectral resolution\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eALS thermostat manages temperature from 4°C to 40°C, ensuring optimal conditions for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eColumn compartment maintains temperature with high stability and accuracy, facilitating reproducible results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes Agilent ChemStation Workstation Software for comprehensive control over data acquisition and analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnables rapid method development with convenient access to four solvents for isocratic or gradient analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_65d96134-6955-446a-84b8-71a73f9fdad0.jpg?v=1779985289\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC System w\/ DAD offers \n\t\u003cspan style=\"background-color: initial;\"\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003ethe most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring \u003c\/span\u003econtinuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to four solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's quaternary pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly which can generate pressure up to 600 bar. Degassing of the solvents is done in a built-in vacuum degasser \u003c\/span\u003eintegrated\u003cspan style=\"letter-spacing: 0px;\"\u003e into the quaternary pump. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. The featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 950 nm, a data \u003c\/span\u003eacquisition\u003cspan style=\"letter-spacing: 0px;\"\u003e rate of up to 80 Hz, and a programmable 1, 2, 4, 8, or 16 nm slit for rapid optimization of \u003c\/span\u003esensitivity\u003cspan style=\"letter-spacing: 0px;\"\u003e, \u003c\/span\u003elinearity\u003cspan style=\"letter-spacing: 0px;\"\u003e, and spectral resolution. \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System w\/ DAD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System w\/ DAD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1311B Quaternary Pump (With Built-In Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4212B DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1311B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System w\/ DAD Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoNormalTable\" style=\"width:348pt; background-color: white;\" cell=\"\" padding=\"0\" width=\"464\" cellspacing=\"0\" border=\"1\"\u003e\n\t\u003c\/table\u003e\n\t\u003ctable border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eDAD Detector\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 640 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.7 × 10^-5 AU at 254 nm and 750 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 × 10^-3 AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLinear Absorbance Range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t ± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm \/ programmable slit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRecorder\/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tController-area network (CAN), GPIB, \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRS-232C, APG Remote: ready, start, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003estop and shut-down signals, LAN\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tExtensive diagnostics, error detection, and display (through control module \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eand ChemStation), leak detection, safe \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak handling, leak output signal for \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eshutdown of pumping system. Low \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003evoltages in major maintenance areas.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eusage in terms of lamp burn time with \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003euser-settable limits and feedback \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emessages. Electronic records of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emaintenance and errors. Verification of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ewavelength accuracy with built-in \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eholmium oxide filter.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAll materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable class=\"MsoTableGrid\" font-size:=\"\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eQuaternary\u003c\/b\u003e\u003cb\u003e Pump\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 10 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 10.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater based on retention time at constant ambient temperature\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min, 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSettable range: 0 - 95% or 5 - 100%\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 0.2 % RSD or \u0026lt; 0.04 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t600 - 900 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments (recommended 1 µl increments)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.25 % RSD of peak areas from 5 - 100 µl, Typically \u0026lt; 1 % RSD of peak areas from 1 - 5 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8850 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 - 50 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t100 × 2 mL vials in 1 tray\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t40 × 2 mL vials in ½ tray\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t15 × 6 mL vials in ½ tray (Agilent vials only)\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t50 s for draw speed 200 µL\/min, ejection speed 200 µl\/min, injection volume 5 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.1 %, \u0026lt; 0.05 % with external needle cleaning\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eALS Thermostat\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eColumn Compartment\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_System_w_DAD_-_Marshall_Scientific.pdf?v=1779985301\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_Manual_-_Marshall_Scientific.pdf?v=1779985297\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2351.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474474373210,"sku":"AG-1260HPLCDAD","price":49290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCDAD-2.jpg?v=1761205157"},{"product_id":"agilent-1260-infinity-i-hplc-system-w-dad-fld","title":"Agilent 1260 Infinity I HPLC System w\/ DAD \u0026 FLD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System w\/ DAD \u0026amp; FLD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 to 640 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (FLD)\u003c\/b\u003e\u003cbr\u003e200 to 1200 nm (Excitation \u0026amp; Emission)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers flexibility for solvent selection and automation in HPLC method development and high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-pressure binary pump supports flow rates from 0.001 to 5 mL\/min with up to 600 bar pressure\n\t\t\t\t\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler designed with a flow-through needle for low carryover and high-speed sample processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit widths in DAD allow for rapid optimization of detection sensitivity and spectral resolution\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFLD enhances detection with high-intensity flash lamp and multi-wavelength spectral scanning capabilities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eALS thermostat manages temperature from 4°C to 40°C, ensuring optimal conditions for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eColumn compartment maintains temperature with high stability and accuracy, facilitating reproducible results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes Agilent ChemStation Workstation Software for comprehensive control over data acquisition and analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnables rapid method development with convenient access to four solvents for isocratic or gradient analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_4b4efab0-19b9-4ce1-990f-48aa1c6d229d.jpg?v=1779992272\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC System w\/ DAD \u0026amp; FLD offers \n\t\u003cspan style=\"background-color: initial;\"\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003ethe most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring \u003c\/span\u003econtinuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to two solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's binary pump is comprises two identical pumps integrated into one housing. Binary gradients are created by high-pressure mixing. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. The pump is capable of delivering flow in the range of 0.1 - 5 mL\/min against up to 600 bar. Degassing of the solvents is done with the High Performance Degasser, which comprises four separate vacuum chambers with semipermeable tubings, a vacuum pump, and control assembly\u003c\/span\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003e. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. \u003c\/span\u003e\u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp\u003e\n\t\tThe featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 950 nm, a data acquisition rate of up to 80 Hz, and a programmable 1, 2, 4, 8, or 16 nm slit for rapid optimization of sensitivity, linearity, and spectral resolution. Also featured is the Fluorescence Detector (FLD), which brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. Some of the features of the FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements. \n\t\t\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity I HPLC System w\/ DAD \u0026amp; FLD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System w\/ DAD \u0026amp; FLD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1312B Binary Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4225A HiP Degasser \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4212B DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1321B FLD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector \u0026amp; G1321B Fluorescence Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System w\/ DAD \u0026amp; FLD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eDAD Detector\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 640 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.7 × 10^-5 AU at 254 nm and 750 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 × 10^-3 AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLinear Absorbance Range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t ± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm \/ programmable slit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eFLD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPerformance Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSingle wavelength operation: • RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLight source\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPulse frequency\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t296 Hz for single signal mode 74 Hz for economy mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tReference System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tIn-line excitation measurement\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable programing\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSpectrum acquisition\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWavelength characteristic\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRepeatability+\/- 0.2 nm Accuracy+\/- 3 nm setting\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow cells\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable class=\"MsoTableGrid\" font-size:=\"\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eBinary Pump\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 5 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tStandard delay volume configuration: 600 - 800 µl, (includes 400 µl mixer), dependent on back pressure\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eLow delay volume configuration: 120 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eAutosampler\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.25% from 5 - 40µl\n\t\t\t\t\u003cbr\u003e\u0026lt; 0.5% from 2 - 5µl\u003cbr\u003e\u0026lt; 0.7% from 1 - 2µl\u003cbr\u003e\u0026lt; 1.5% from 0.5 - 1µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tUp to 600 bar (8,700 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\t\u003cbr\u003e108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\u003cbr\u003e30 x 6 ml vials in 2 x 15 vial plate\u003cbr\u003e100 Micro vial tray plus 10 additional 2 ml vials\u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plates\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 21 seconds using default conditions and injection volume of 5µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eALS Thermostat\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eColumn Compartment\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eHigh Performance Degasser\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.45 mL per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTFE\/PDD Copolymer, FEP, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_System_w_DAD___FLD_-_Marshall_Scientific_9228f299-27ec-473f-a481-860f45b744c4.pdf?v=1779992275\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_Binary_System_Manual_-_Marshall_Scientific_7d12f7b6-bdef-4502-9ea6-5d53206700b2.pdf?v=1779992278\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2433.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474474733658,"sku":"AG-1260HPLCDADFLD","price":48995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCDADFLD-2.jpg?v=1761205187"},{"product_id":"agilent-1260-infinity-ii-lc-system-w-dad","title":"Agilent 1260 Infinity II LC System w\/ DAD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II LC System w\/ DAD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e 190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 10 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003e0 to 600 bar (0 to 60 MPa) at 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers ultra fast and high resolution separation for consistently accurate results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a quaternary pump with a 600 bar operating pressure, suitable for HPLC and UHPLC\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDiode Array Detector (DAD) provides high optical performance with a wavelength range of 190 – 950 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDetector includes RFID tags for traceable maintenance of flow cells and UV-lamps\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in temperature controls and diagnostics enhance baseline stability and performance monitoring\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMulticolumn Thermostat (MCT) supports precise temperature control from 10°C below ambient to 85°C\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controllable via Agilent OpenLab CDS Software for simplified operation and data management\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCDADII_0d98afa0-0f2e-4269-8d83-36d995670cd4.png?v=1779985510\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ DAD provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar the 1260 Infinity II Quaternary Pump is compatible with HPLC and UHPLC, i.e. handling 2.1, 3, and 4.6 mm ID columns over the flow rate range (up to 5 mL\/min) and semi preparative analysis due to flow up to 10 mL\/min. The 1260 Infinity II Multisampler can handle both vials and microtiter plates with ease and efficiency, and is designed for low carryover, as you can take clean to a whole new level with the multi-wash capability, cleaning all relevant injection parts between runs. This integrated feature flushes the injection needle outside with three solvents, and uses seat back flush procedures to reduce carryover to less than 9 ppm. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe 1260 Infinity II Diode Array Detector (DAD) is designed for highest optical performance, GLP compliance, and easy maintenance. With its 120 Hz data acquisition rate, the detector is perfectly suited for fast LC applications. The long-life deuterium lamps allow for the highest intensity and lowest detection limits over a wavelength range of 190 – 950 nm. The use of RFID tags for all flow cells and UV-lamps provides traceable information about these assemblies. The built-in holmium oxide filter features fast wavelength accuracy verification, while the built-in temperature controls improve the baseline stability. Additional diagnostic signals for temperature and lamp voltage monitoring are available. The Agilent 1260 Infinity II Multicolumn Thermostat (MCT) allows precise column thermostatting over a broad temperature range: from cooling down to 10 degrees below ambient temperature up to 85°C, providing high flexibility for optimized speed and selectivity of LC separation. For bio-inert applications bio-inert heat exchangers and a selection of bio-inert valves are offered by Agilent.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ DAD can be fully controlled from the Agilent OpenLab CDS Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II LC System w\/ DAD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG7111B Quaternary Pump (With Integrated Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7115A DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7167A Multisampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7116A Multicolumn Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOpenLab CDS Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7115A Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7111B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7116A Multicolumn Thermostat Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7167A Multisampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the Agilent 1260 Infinity II LC System w\/ MWD.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II LC System w\/ DAD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDAD Detector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 120 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.7 x 10^-5 AU, at 254 and 750 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 x 10^-3 AU\/h at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity II LC System w\/ DAD\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tQuaternary Pump\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDual piston in series pump with servo-controlled variable stroke driven, powe transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSet points 0.001 - 10 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t0.02 - 10.0 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 20 MPa (200 bar, 2950 psi) up to 10 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.0%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary high-speed proportioning valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Composition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0 - 100% in 0.1% increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.2% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIntegrated Degassing Unit\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tNumber of channels: 4\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tInternal volume per channel: 1.5 ml\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultisampler\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.1 - 90 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.15% RSD or SD \u0026lt; 10nL, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Linearity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.9999 in the range of 0.1 - 100 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUp to 800 bar\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1H Drawer: up to 8 drawers and 16 positions\n\t\t\t\t\u003cbr\u003eShallow well plates (MTP)\u003cbr\u003e\u003cbr\u003e2H Drawer: up to 4 drawers and 8 positions\u003cbr\u003eMTP, deep well plates, vials, Eppendorf\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e3H Drawer: up to 2 drawers and 4 positions\u003cbr\u003eMTP, deep well plates, vials up to 6 ml, Eppendorf\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 10 seconds using following conditions:\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eDefault draw speed: 100 ul\/min\u003cbr\u003eDefault eject speed: 400 ul\/min\u003cbr\u003eInjection volume: 1 ul\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultiwash\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tOuter needle wash and seat backflush for carryover reduction with up to 3 different solvents\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCarry Over\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.003% (30 ppm) Multisampler Standard Needle\n\t\t\t\t\u003cbr\u003e\u003cbr\u003e\u0026lt;0.0009% (3 ppm) Multisampler Multiwash\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMulticolumn Thermostat\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tAmbient -10°C to 85°C (minimum 4°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.1°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (with calibration for 40°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.05°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIndependent Temperature Zones\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t2 in single device\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t4 columns of up to 300 mm length plus InfinityLab Quick-Connect fittings or pre-column The number of precolumn Quick-Connect Heat Exchangers is scalable - each column can be equipped with individual heat exchanger for best performance 4-column selector valve is available to access each column without replumbing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHeat-Up \/ Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t5 min from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 min from 40°C to 20°C\u003cbr\u003e\u0026lt; 25 min from 25°C to 85°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_DAD_-_Marshall_Scientific.pdf?v=1779985515\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_MWD_Manual_-_Marshall_Scientific.pdf?v=1779985520\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2502.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474476011610,"sku":"AG-1260HPLCDADII","price":51995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCDADII-2.jpg?v=1761205222"},{"product_id":"agilent-1260-infinity-i-hplc-system-w-vwd-fld","title":"Agilent 1260 Infinity I HPLC System w\/ VWD \u0026 FLD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System w\/ VWD \u0026amp; FLD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (VWD)\u003c\/b\u003e\u003cbr\u003e190 to 600 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (FLD)\u003c\/b\u003e\u003cbr\u003e200 to 1200 nm (Excitation \u0026amp; Emission)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers flexibility for solvent selection and automation in HPLC method development and high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh-pressure binary pump supports flow rates from 0.001 to 5 mL\/min with up to 600 bar pressure\n\t\t\t\t\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler designed with a flow-through needle for low carryover and high-speed sample processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eVWD Detector features a double-beam photometer with a deuterium lamp for maximum light intensity and sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFLD enhances detection with high-intensity flash lamp and multi-wavelength spectral scanning capabilities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eALS thermostat manages temperature from 4°C to 40°C, ensuring optimal conditions for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eColumn compartment maintains temperature with high stability and accuracy, facilitating reproducible results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes Agilent ChemStation Workstation Software for comprehensive control over data acquisition and analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnables rapid method development with convenient access to four solvents for isocratic or gradient analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_4b4efab0-19b9-4ce1-990f-48aa1c6d229d.jpg?v=1779992272\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC System w\/ VWD \u0026amp; FLD offers \n\t\u003cspan style=\"background-color: initial;\"\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003ethe most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring \u003c\/span\u003econtinuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to two solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's binary pump is comprises two identical pumps integrated into one housing. Binary gradients are created by high-pressure mixing. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. The pump is capable of delivering flow in the range of 0.1 - 5 mL\/min against up to 600 bar. Degassing of the solvents is done with the High Performance Degasser, which comprises four separate vacuum chambers with semipermeable tubings, a vacuum pump, and control assembly\u003c\/span\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003e. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. The featured Variable Wavelength Detector (VWD) is designed for the highest optical UV performance, GLP compliance, and easy maintenance. The VWD features a deuterium lamp for the highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm. This detector also features a dual-wavelength mode to acquire even more sample information, along with time-programmable wavelength switching to provide optimum sensitivity and selectivity for your applications. The featured Fluorescence Detector (FLD) brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. Some of the features of the FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements. \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity I HPLC System w\/ VWD \u0026amp; FLD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System w\/ VWD \u0026amp; FLD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1312B Binary Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4225A HiP Degasser \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1314F VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1321B FLD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1314F Variable Wavelength Detector \u0026amp; G1321B Fluorescence Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System w\/ VWD \u0026amp; FLD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cstrong\u003eVWD Detector\u003c\/strong\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.5 × 10^-5 AU at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3 × 10^-4 AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.0 AU (5%) upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBand Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5 nm typical\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t55 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tAgilent ChemStation for LC\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eFLD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPerformance Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSingle wavelength operation: • RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLight source\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPulse frequency\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t296 Hz for single signal mode 74 Hz for economy mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tReference System:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tin-line excitation measurement\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable programing\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSpectrum acquisition:\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWavelength characteristic\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRepeatability+\/- 0.2 nm Accuracy+\/- 3 nm setting\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow cells\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable class=\"MsoTableGrid\" font-size:=\"\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eBinary Pump\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 5 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tStandard delay volume configuration: 600 - 800 µl, (includes 400 µl mixer), dependent on back pressure\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eLow delay volume configuration: 120 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eAutosampler\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.25% from 5 - 40µl\n\t\t\t\t\u003cbr\u003e\u0026lt; 0.5% from 2 - 5µl\u003cbr\u003e\u0026lt; 0.7% from 1 - 2µl\u003cbr\u003e\u0026lt; 1.5% from 0.5 - 1µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tUp to 600 bar (8,700 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\t\u003cbr\u003e108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\u003cbr\u003e30 x 6 ml vials in 2 x 15 vial plate\u003cbr\u003e100 Micro vial tray plus 10 additional 2 ml vials\u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plates\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 21 seconds using default conditions and injection volume of 5µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eALS Thermostat\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eColumn Compartment\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eHigh Performance Degasser\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.45 mL per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTFE\/PDD Copolymer, FEP, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_System_w_VWD___FLD_-_Marshall_Scientific_89dd3ab8-bfdb-4d95-82c8-c5817b54388d.pdf?v=1779992284\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_Binary_System_Manual_-_Marshall_Scientific_7d12f7b6-bdef-4502-9ea6-5d53206700b2.pdf?v=1779992278\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2412.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474476240986,"sku":"AG-1260HPLCFLD","price":46995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCFLD-2.jpg?v=1761205254"},{"product_id":"agilent-1260-infinity-ii-lc-system-w-mwd","title":"Agilent 1260 Infinity II LC System w\/ MWD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II LC System w\/ MWD\u003c\/h1\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ MWD provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar the 1260 Infinity II Quaternary Pump is compatible with HPLC and UHPLC, i.e. handling 2.1, 3, and 4.6 mm ID columns over the flow rate range (up to 5 mL\/min) and semi preparative analysis due to flow up to 10 mL\/min. The 1260 Infinity II Multisampler can handle both vials and microtiter plates with ease and efficiency, and is designed for low carryover, as you can take clean to a whole new level with the multi-wash capability, cleaning all relevant injection parts between runs. This integrated feature flushes the injection needle outside with three solvents, and uses seat back flush procedures to reduce carryover to less than 9 ppm. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe 1260 Infinity II Multiple Wavelength Detector (MWD) is designed for highest optical performance, GLP compliance, and easy maintenance. With its 120 Hz data acquisition rate, the detector is perfectly suited for fast LC applications. The long-life deuterium lamps allow for the highest intensity and lowest detection limits over a wavelength range of 190 – 950 nm. The use of RFID tags for all flow cells and UV-lamps provides traceable information about these assemblies. The built-in holmium oxide filter features fast wavelength accuracy verification, while the built-in temperature controls improve the baseline stability. Additional diagnostic signals for temperature and lamp voltage monitoring are available. The Agilent 1260 Infinity II Multicolumn Thermostat (MCT) allows precise column thermostatting over a broad temperature range: from cooling down to 10 degrees below ambient temperature up to 85°C, providing high flexibility for optimized speed and selectivity of LC separation. For bio-inert applications bio-inert heat exchangers and a selection of bio-inert valves are offered by Agilent.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ MWD can be fully controlled from the Agilent OpenLab CDS Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II LC System w\/ MWD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG7111B Quaternary Pump (With Integrated Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7165A MWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7167A Multisampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7116A Multicolumn Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOpenLab CDS Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7165A Multiple Wavelength Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7111B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7116A Multicolumn Thermostat Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7167A Multisampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the Agilent 1260 Infinity II LC System w\/ MWD.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II LC System w\/ MWD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMWD Detector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 120 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.7 x 10^-5 AU, at 254 and 750 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 x 10^-3 AU\/h at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity II LC System w\/ MWD\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tQuaternary Pump\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDual piston in series pump with servo-controlled variable stroke driven, powe transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSet points 0.001 - 10 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t0.02 - 10.0 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 20 MPa (200 bar, 2950 psi) up to 10 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.0%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary high-speed proportioning valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Composition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0 - 100% in 0.1% increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.2% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIntegrated Degassing Unit\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tNumber of channels: 4\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tInternal volume per channel: 1.5 ml\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultisampler\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.1 - 90 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.15% RSD or SD \u0026lt; 10nL, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Linearity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.9999 in the range of 0.1 - 100 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUp to 800 bar\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1H Drawer: up to 8 drawers and 16 positions\n\t\t\t\t\u003cbr\u003eShallow well plates (MTP)\u003cbr\u003e\u003cbr\u003e2H Drawer: up to 4 drawers and 8 positions\u003cbr\u003eMTP, deep well plates, vials, Eppendorf\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e3H Drawer: up to 2 drawers and 4 positions\u003cbr\u003eMTP, deep well plates, vials up to 6 ml, Eppendorf\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 10 seconds using following conditions:\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eDefault draw speed: 100 ul\/min\u003cbr\u003eDefault eject speed: 400 ul\/min\u003cbr\u003eInjection volume: 1 ul\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultiwash\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tOuter needle wash and seat backflush for carryover reduction with up to 3 different solvents\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCarry Over\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.003% (30 ppm) Multisampler Standard Needle\n\t\t\t\t\u003cbr\u003e\u003cbr\u003e\u0026lt;0.0009% (3 ppm) Multisampler Multiwash\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMulticolumn Thermostat\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tAmbient -10°C to 85°C (minimum 4°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.1°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (with calibration for 40°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.05°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIndependent Temperature Zones\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t2 in single device\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t4 columns of up to 300 mm length plus InfinityLab Quick-Connect fittings or pre-column The number of precolumn Quick-Connect Heat Exchangers is scalable - each column can be equipped with individual heat exchanger for best performance 4-column selector valve is available to access each column without replumbing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHeat-Up \/ Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t5 min from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 min from 40°C to 20°C\u003cbr\u003e\u0026lt; 25 min from 25°C to 85°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_MWD_-_Marshall_Scientific.pdf?v=1779985527\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_MWD_Manual_-_Marshall_Scientific.pdf?v=1779985520\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2475.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474476306522,"sku":"AG-1260HPLCMWDII","price":49995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCMWDII-2.jpg?v=1761205287"},{"product_id":"agilent-1260-infinity-i-hplc-system-w-quat-pump-dad-fld","title":"Agilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026 FLD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026amp; FLD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 to 640 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (FLD)\u003c\/b\u003e\u003cbr\u003e200 to 1200 nm (Excitation \u0026amp; Emission)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 10 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers flexibility for solvent selection and automation in HPLC method development and high-throughput workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a vacuum degasser integrated into the pump for efficient degassing of solvents\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eQuaternary pump accommodates a wide range of solvent compatibilities and mixing capabilities for diverse HPLC applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler designed with a flow-through needle for low carryover and high-speed sample processing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit widths in DAD allow for rapid optimization of detection sensitivity and spectral resolution\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFLD enhances detection with high-intensity flash lamp and multi-wavelength spectral scanning capabilities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eALS thermostat manages temperature from 4°C to 40°C, ensuring optimal conditions for sensitive analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eColumn compartment maintains temperature with high stability and accuracy, facilitating reproducible results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes Agilent ChemStation Workstation Software for comprehensive control over data acquisition and analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEnables rapid method development with convenient access to four solvents for isocratic or gradient analysis\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_65d96134-6955-446a-84b8-71a73f9fdad0.jpg?v=1779985289\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026amp; FLD offers the most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring continuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to four solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's quaternary pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly which can generate pressure up to 600 bar. Degassing of the solvents is done in a built-in vacuum degasser integrated into the quaternary pump. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. \u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp\u003e\n\t\tThe featured Diode-Array Detector (DAD) is designed for the highest optical performance, GLP compliance, and easy maintenance. The DAD provides greatly enhanced sensitivity and baseline stability using a cartridge cell system with optofluidic waveguides. This detector provides for a wavelength range of 190 - 950 nm, a data acquisition rate of up to 80 Hz, and a programmable 1, 2, 4, 8, or 16 nm slit for rapid optimization of sensitivity, linearity, and spectral resolution. Also featured is the Fluorescence Detector (FLD), which brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. Some of the features of the FLD Detector include; a flash lamp for highest intensity and lowest detection limit, multi-wavelength mode for on-line spectra, spectra acquisition and simultaneous multi-signal detection, easy front access to the flow cell for fast replacement, and built-in wavelength accuracy verification. Users may also use an optional cuvette for off-line measurements. \n\t\t\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026amp; FLD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026amp; FLD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1311B Quaternary Pump (With Built-In Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4212B DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1321B FLD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG4212B Diode Array Detector \u0026amp; G1321B Fluorescence Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1311B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System w\/ Quat Pump, DAD, \u0026amp; FLD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eDAD Detector\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 640 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.7 × 10^-5 AU at 254 nm and 750 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 × 10^-3 AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLinear Absorbance Range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t ± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm \/ programmable slit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eFLD Detector\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPerformance Specifications\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSingle wavelength operation: • RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell • RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value) Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell Dual wavelength operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell.\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLight source\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPulse frequency\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t296 Hz for single signal mode 74 Hz for economy mode\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tEmission Monochromator\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRange: settable 200 nm - 1200 nm and zero-order Bandwidth: 20 nm (fixed) Monochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tReference System\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tIn-line excitation measurement\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTimetable programing\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tup to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSpectrum acquisition\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tExcitation or Emission spectra Scan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step) Step size: 1 – 20 nm Spectra storage: All\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWavelength characteristic\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRepeatability+\/- 0.2 nm Accuracy+\/- 3 nm setting\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFlow cells\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tStandard: 8 µl volume and 20 bar (2 MPa) pressure maximum, quartz Optional: Fluorescence cuvette for offline spectroscopic measurements with 1 ml syringe, 8 µl volume, quartz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable class=\"MsoTableGrid\" font-size:=\"\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eQuaternary\u003c\/b\u003e\u003cb\u003e Pump\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 10 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 10.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater based on retention time at constant ambient temperature\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min, 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSettable range: 0 - 95% or 5 - 100%\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 0.2 % RSD or \u0026lt; 0.04 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t600 - 900 µl, dependent on back pressure\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eAutosampler\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u0026lt; 0.25% from 5 - 40µl\n\t\t\t\t\u003cbr\u003e\u0026lt; 0.5% from 2 - 5µl\u003cbr\u003e\u0026lt; 0.7% from 1 - 2µl\u003cbr\u003e\u0026lt; 1.5% from 0.5 - 1µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tUp to 600 bar (8,700 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials\n\t\t\t\t\u003cbr\u003e108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\u003cbr\u003e30 x 6 ml vials in 2 x 15 vial plate\u003cbr\u003e100 Micro vial tray plus 10 additional 2 ml vials\u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plates\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 21 seconds using default conditions and injection volume of 5µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eALS Thermostat\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eColumn Compartment\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\t\u003cbr\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t5 minutes from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_System_w_Quat_Pump__DAD____FLD_-_Marshall_Scientific.pdf?v=1779985318\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_Manual_-_Marshall_Scientific.pdf?v=1779985297\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2434.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"No Additional Detector Needed","offer_id":42474476535898,"sku":"AG-1260HPLCQDADFLD","price":47610.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity I HPLC G1362A RID Detector","offer_id":42474476568666,"sku":"AG-1260HPLCQDADFLD","price":47610.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCQDADFLD-2.jpg?v=1761205321"},{"product_id":"agilent-1260-infinity-i-hplc-system-w-vwd","title":"Agilent 1260 Infinity I HPLC System w\/ VWD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC System w\/ VWD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (VWD)\u003c\/b\u003e\u003cbr\u003e 190 to 600 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003e0 to 600 bar (0 to 60 MPa) at 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eOffers flexible solvent selection and automation for diverse HPLC applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures dual solvent access for rapid method development and efficient system flushing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBinary pump with high-pressure mixing supports fast gradients and high throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlow rates range from 0.1 to 5 mL\/min, with a maximum pressure of 600 bar\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh Performance Degasser ensures effective solvent degassing with separate vacuum chambers\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutosampler designed for minimal carryover, enhancing speed, sensitivity, and precision\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eThermostatted column compartment and ALS thermostat provide precise temperature control\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eVariable Wavelength Detector (VWD) ensures high optical UV performance from 190 to 600 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDual-wavelength mode and programmable wavelength switching for optimized sensitivity and selectivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controllable via Agilent ChemStation Workstation Software for simplified operation and data management\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLC_65d96134-6955-446a-84b8-71a73f9fdad0.jpg?v=1779985289\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity I HPLC System w\/ VWD offers \n\t\u003cspan style=\"background-color: initial;\"\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003ethe most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring \u003c\/span\u003econtinuous\u003cspan style=\"letter-spacing: 0px;\"\u003e access to a wide range of solvent choices. This system is ideally suited for multi-method, high-throughput workflows and offers \u003c\/span\u003econvenient\u003cspan style=\"letter-spacing: 0px;\"\u003e access to two solvents for isocratic or gradient analysis, for rapid method development and speeding up preparation of mobile phases and flushing the HPLC system. \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System's binary pump is comprises two identical pumps integrated into one housing. Binary gradients are created by high-pressure mixing. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. The pump is capable of delivering flow in the range of 0.1 - 5 mL\/min against up to 600 bar. Degassing of the solvents is done with the High Performance Degasser, which comprises four separate vacuum chambers with semipermeable tubings, a vacuum pump, and control assembly\u003c\/span\u003e\u003cspan style=\"letter-spacing: 0px;\"\u003e. The 1260 Infinity Autosampler is designed to offer the well-established flow-through design with variable volume \u003c\/span\u003einjection\u003cspan style=\"letter-spacing: 0px;\"\u003e and to achieve extremely low carryover, providing increased analysis speed with sensitivity, resolution, and \u003c\/span\u003eprecision\u003cspan style=\"letter-spacing: 0px;\"\u003e. Paired with the autosampler is a thermostatted column compartment and ALS thermostat to serve as a temperature management system providing heating and cooling in order to meet extreme requirements of \u003c\/span\u003eretention\u003cspan style=\"letter-spacing: 0px;\"\u003e time reproducibility. The featured Variable Wavelength Detector (VWD) is designed for the highest optical UV performance, GLP compliance, and easy maintenance. The VWD features a deuterium lamp for the highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm. This detector also features a dual-wavelength mode to acquire even more sample information, along with t\u003c\/span\u003eime-programmable wavelength switching to provide optimum sensitivity and selectivity for your applications. \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eThe Agilent 1260 Infinity HPLC System w\/ VWD can be fully controlled from the included Agilent ChemStation Workstation Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\u003c\/span\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC System w\/ VWD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG1312B Binary Pump\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1329B Autosampler \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1330B ALS Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1316A TCC \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG4225A HiP Degasser \u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG1314F VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nChemStation Version 4.3 Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1314F Variable Wavelength Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1312B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1316A Column Compartment Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG1329B Autosampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the 1260 Infinity HPLC System.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC System w\/ VWD Specifications\u003c\/h2\u003e\n\t\u003ctable class=\"MsoNormalTable\" style=\"width:348pt; background-color: white;\" cell=\"\" padding=\"0\" width=\"464\" cellspacing=\"0\" border=\"1\"\u003e\n\t\u003c\/table\u003e\n\t\u003ctable border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eVWD Detector\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cb\u003eSpecification\u003c\/b\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.5 × 10^-5 AU at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t3 × 10^-4 AU\/hr at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\u0026gt; 2.0 AU (5%) upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tBand Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5 nm typical\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t55 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tStandard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRecorder\/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\tController-area network (CAN), GPIB, \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRS-232C, APG Remote: ready, start, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003estop and shut-down signals, LAN\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tExtensive diagnostics, error detection, and display (through control module \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eand ChemStation), leak detection, safe \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak handling, leak output signal for \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eshutdown of pumping system. Low \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003evoltages in major maintenance areas.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eusage in terms of lamp burn time with \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003euser-settable limits and feedback \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emessages. Electronic records of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emaintenance and errors. Verification of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ewavelength accuracy with built-in \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eholmium oxide filter.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\tAll materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity HPLC System\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eBinary Pump\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 - 5 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.05 - 5.0 mL\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.07% RSD or \u0026lt; 0.02 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tStandard delay volume configuration: 600 - 800 µl, (includes 400 µl mixer), dependent on back pressure \n\t\t\t\t\u003cbr\u003e\u003cbr\u003eLow delay volume configuration: 120 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eAutosampler\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPrecision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.25% from 5 - 40µl \n\t\t\t\t\u003cbr\u003e\u0026lt; 0.5% from 2 - 5µl\u003cbr\u003e\u0026lt; 0.7% from 1 - 2µl\u003cbr\u003e\u0026lt; 1.5% from 0.5 - 1µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tUp to 600 bar (8,700 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t2 x well plates (MTP) + 10 x 2 ml vials \n\t\t\t\t\u003cbr\u003e108 x 2 ml vials in 2 x 54 vial plate plus 10 additional 2 ml vials\u003cbr\u003e30 x 6 ml vials in 2 x 15 vial plate\u003cbr\u003e100 Micro vial tray plus 10 additional 2 ml vials\u003cbr\u003e54 Eppendorf tubes (0.5\/1.5\/2 ml) in 2 x 27 Eppendorf tube plates\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 21 seconds using default conditions and injection volume of 5µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTypically \u0026lt; 0.004%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eALS Thermostat\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4°C to 40°C in 1°C increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026lt; 25°C and Humidity \u0026lt; 50%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to 8°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy at Ambient Temperatures \u0026gt; 30°C and Humidity \u0026gt; 60%\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t3°C to 9°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eColumn Compartment\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 80°C at flow rates up to 5 mL\/min\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.15°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.8°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 minutes from ambient to 40°C \n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eHigh Performance Degasser\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cstrong\u003eSpecification\u003c\/strong\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tNumber of Solvent Channels\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 10 mL\/min per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInternal Volume Per Channel\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.45 mL per channel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTFE\/PDD Copolymer, FEP, PEEK\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 14\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_System_w_VWD_-_Marshall_Scientific.pdf?v=1779985324\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_Binary_System_Manual_-_Marshall_Scientific.pdf?v=1779985312\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2352.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"No Additional Detector Needed","offer_id":42474476896346,"sku":"AG-1260HPLCVWD","price":43490.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity I HPLC G1362A RID Detector","offer_id":42474476929114,"sku":"AG-1260HPLCVWD","price":43490.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCVWD-2.jpg?v=1761205352"},{"product_id":"agilent-1260-infinity-ii-lc-system-w-vwd","title":"Agilent 1260 Infinity II LC System w\/ VWD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II LC System w\/ VWD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (VWD)\u003c\/b\u003e\u003cbr\u003e 190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 10 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range \u003c\/b\u003e\u003cbr\u003e0 to 600 bar (0 to 60 MPa) at 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eUltra-fast and high-resolution separation capability for precise results\u003c\/li\u003e\n\u003cli\u003eOperates up to 600 bar with compatibility for HPLC and UHPLC columns\u003c\/li\u003e\n\u003cli\u003eQuaternary pump supports flow rates up to 10 mL\/min for versatile applications\u003c\/li\u003e\n\u003cli\u003eMultisampler handles vials and microtiter plates with low carryover\u003c\/li\u003e\n\u003cli\u003eMultiwash capability reduces carryover to less than 9 ppm\u003c\/li\u003e\n\u003cli\u003eVariable Wavelength Detector offers dual-wavelength detection with low noise\u003c\/li\u003e\n\u003cli\u003eBroad temperature range from Ambient -10°C to 85°C with precise thermostatting\u003c\/li\u003e\n\u003cli\u003eIntegrated degassing unit with four channels for reliable solvent management\u003c\/li\u003e\n\u003cli\u003eTime-programmable wavelength switching enhances sensitivity and selectivity\u003c\/li\u003e\n\u003cli\u003eGradient mixing capability with proprietary high-speed proportioning valve\u003c\/li\u003e\n\u003cli\u003eSoftware-controlled operation for data acquisition, analysis, and automation\u003c\/li\u003e\n\u003cli\u003eCompact design supports up to four columns with InfinityLab Quick-Connect fittings\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCDADII_0d98afa0-0f2e-4269-8d83-36d995670cd4.png?v=1779985510\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ VWD provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar the 1260 Infinity II Quaternary Pump is compatible with HPLC and UHPLC, i.e. handling 2.1, 3, and 4.6 mm ID columns over the flow rate range (up to 5 mL\/min) and semi preparative analysis due to flow up to 10 mL\/min. The 1260 Infinity II Multisampler can handle both vials and microtiter plates with ease and efficiency, and is designed for low carryover, as you can take clean to a whole new level with the multi-wash capability, cleaning all relevant injection parts between runs. This integrated feature flushes the injection needle outside with three solvents, and uses seat back flush procedures to reduce carryover to less than 9 ppm. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II Variable Wavelength Detector (VWD) is the most sensitive and fastest detector in its class. The detector features time-programmable wavelength switching provides sensitivity and selectivity for your applications. More sample information can be acquired in the dual wavelength mode. Low detector noise (\u0026lt; ± 2.5 AU) and baseline drift (\u0026lt; 1 x 10^-4 AU\/h) facilitates precise quantification of trace levels components. High productivity can be achieved with fast analysis at up to 120 Hz data rates. The Agilent 1260 Infinity II Multicolumn Thermostat (MCT) allows precise column thermostatting over a broad temperature range: from cooling down to 10 degrees below ambient temperature up to 85°C, providing high flexibility for optimized speed and selectivity of LC separation. For bio-inert applications bio-inert heat exchangers and a selection of bio-inert valves are offered by Agilent.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ VWD can be fully controlled from the Agilent OpenLab CDS Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II LC System w\/ VWD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG7111B Quaternary Pump (With Integrated Degasser)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7114A VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7167A Multisampler\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7116A Multicolumn Thermostat\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOpenLab CDS Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7114A Variable Wavelength Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7111B Quaternary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7116A Multicolumn Thermostat Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7167A Multisampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the Agilent 1260 Infinity II LC System w\/ VWD.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003e\u003cspan style=\"background-color: initial;\"\u003eAgilent 1260 Infinity II LC System w\/ VWD Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVWD Detector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.25 x 10^-5 AU, at 230 nm (single wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.80 x 10^-5 AU, at 230 nm and 254 nm (dual wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 x 10^-4 AU\/h at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.5 AU upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5nm typical over whole wavelength range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp on\/off\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 14 µl volume, 10 mm cell path length and 40 bar (588 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStop-flow wavelength scan\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity II LC System w\/ VWD\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tQuaternary Pump\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDual piston in series pump with servo-controlled variable stroke driven, powe transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSet points 0.001 - 10 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t0.02 - 10.0 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tUp to 20 MPa (200 bar, 2950 psi) up to 10 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.0%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary high-speed proportioning valve\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSettable Composition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0 - 100% in 0.1% increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.2% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIntegrated Degassing Unit\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tNumber of channels: 4\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\tInternal volume per channel: 1.5 ml\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultisampler\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.1 - 90 µl in 0.1 µl increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.15% RSD or SD \u0026lt; 10nL, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Linearity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.9999 in the range of 0.1 - 100 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tUp to 800 bar\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t1H Drawer: up to 8 drawers and 16 positions\n\t\t\t\t\u003cbr\u003eShallow well plates (MTP)\u003cbr\u003e\u003cbr\u003e2H Drawer: up to 4 drawers and 8 positions\u003cbr\u003eMTP, deep well plates, vials, Eppendorf\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e3H Drawer: up to 2 drawers and 4 positions\u003cbr\u003eMTP, deep well plates, vials up to 6 ml, Eppendorf\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 10 seconds using following conditions:\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eDefault draw speed: 100 ul\/min\u003cbr\u003eDefault eject speed: 400 ul\/min\u003cbr\u003eInjection volume: 1 ul\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMultiwash\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tOuter needle wash and seat backflush for carryover reduction with up to 3 different solvents\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tCarry Over\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.003% (30 ppm) Multisampler Standard Needle\n\t\t\t\t\u003cbr\u003e\u003cbr\u003e\u0026lt;0.0009% (3 ppm) Multisampler Multiwash\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tMulticolumn Thermostat\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tAmbient -10°C to 85°C (minimum 4°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.1°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (with calibration for 40°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tTemperature Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t0.05°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tIndependent Temperature Zones\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t2 in single device\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t4 columns of up to 300 mm length plus InfinityLab Quick-Connect fittings or pre-column The number of precolumn Quick-Connect Heat Exchangers is scalable - each column can be equipped with individual heat exchanger for best performance 4-column selector valve is available to access each column without replumbing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\tHeat-Up \/ Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t5 min from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 min from 40°C to 20°C\u003cbr\u003e\u0026lt; 25 min from 25°C to 85°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_VWD_-_Marshall_Scientific.pdf?v=1779985558\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_VWD_Manual_-_Marshall_Scientific.pdf?v=1779985563\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2474.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"No Additional Detector Needed","offer_id":42474477125722,"sku":"AG-1260HPLCVWDII","price":44730.0,"currency_code":"USD","in_stock":false},{"title":"Agilent 1260 Infinity II HPLC G7162A RID Detector","offer_id":42474477158490,"sku":"AG-1260HPLCVWDII","price":44730.0,"currency_code":"USD","in_stock":false},{"title":"Agilent 1260 Infinity II HPLC G7165A MWD Detector","offer_id":42474477191258,"sku":"AG-1260HPLCVWDII","price":44730.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260HPLCVWDII-2.jpg?v=1761205384"},{"product_id":"agilent-1260-infinity-ii-hplc-g7116a-multicolumn-thermostat","title":"Agilent 1260 Infinity II HPLC G7116A Multicolumn Thermostat","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7116A Multicolumn Thermostat\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003eAmbient -10°C to 85°C (minimum 4°C)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Stability\u003c\/b\u003e\u003cbr\u003e± 0.1°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Accuracy\u003c\/b\u003e\u003cbr\u003e± 0.5°C (with calibration for 40°C)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eExchangeable high-pressure valves support a wide range of applications and up to four columns\u003c\/li\u003e\n\u003cli\u003eFeatures two independent temperature zones within a single device\u003c\/li\u003e\n\u003cli\u003eAccommodates four columns up to 300 mm length, with scalability for individual column heat exchangers\u003c\/li\u003e\n\u003cli\u003eQuick and efficient temperature adjustment with heat-up\/cool-down times as short as 5 minutes\u003c\/li\u003e\n\u003cli\u003eFlexible flap positions for easy access, with options for 90° or 180° opening or front door removal\u003c\/li\u003e\n\u003cli\u003eSuperior column exchange convenience through InfinityLab Quick Connect Fittings\u003c\/li\u003e\n\u003cli\u003eOptional column identification kit for tracking history and usage of up to four columns (not included)\u003c\/li\u003e\n\u003cli\u003eOffers valve drive options for user-exchangeable, bio-inert valve heads for versatile laboratory needs\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IIMCT_838c40d7-3bc9-4b3b-b43a-674ac547f9ab.jpg?v=1779985404\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7116A Multicolumn Thermostat (MCT) offers advanced column thermostatting, capable of cooling to 10°C below ambient and heating up to 85°C for enhanced separation reliability across diverse applications. It features exchangeable high-pressure valves for versatile column selection up to four columns, accommodating columns up to 300 mm in length with InfinityLab Quick-Connect fittings or pre-columns. The device ensures precise temperature control with stability at ± 0.1°C and accuracy at ± 0.5°C, complemented by two independent temperature zones for optimized performance.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe G7116A MCT heats up and cools down swiftly, taking less than 25 minutes to reach its maximum temperature. Enhanced usability is provided through adjustable flap positions, allowing for easy access and maintenance, along with InfinityLab Quick Connect Fittings for rapid column exchange. Additionally, it offers optional enhancements such as a column identification kit for tracking column history and valve drives for user-exchangeable valve heads, available in bio-inert materials for specialized applications.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7116A Multicolumn Thermostat includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nThermostat Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7116A Multicolumn Thermostat Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient -10°C to 85°C (minimum 4°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Stability\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.1°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 0.5°C (with calibration for 40°C)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTemperature Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.05°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIndependent Temperature Zones\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 in single device\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tColumn Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 columns of up to 300 mm length plus InfinityLab Quick-Connect fittings or pre-column. The number of precolumn Quick-Connect Heat Exchangers is scalable - each column can be equipped with individual heat exchanger for best performance 4-column selector valve is available to access each column without replumbing\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHeat-Up \/ Cool-Down Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5 min from Ambient to 40°C\n\t\t\t\u003cbr\u003e10 min from 40°C to 20°C\u003cbr\u003e\u0026lt; 25 min from 25°C to 85°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSolvent Heat Exchangers\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tIndividually quick-installable for every column. Available at 3 µL internal volume, 0.17 mm i.d. capillary (large ID), 6 µL internal volume, 0.17 mm i.d. capillary (large ID high flow) and 9 µL internal volume, 0.17 mm i.d. capillary (bio-inert, metal-free)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tColumn Identification\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tColumn identification kit available to track history of up to four columns\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.3 x 17.1 x 17.2 in. (16 x 43.5 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t27.6 lb. (12.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 150VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7116A_Multicolumn_Thermostat_-_Marshall_Scientific.pdf?v=1779985408\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7116A_Multicolumn_Thermostat_Manual_-_Marshall_Scientific.pdf?v=1779985412\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2766.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474477289562,"sku":"AG-1260IIMCT","price":4025.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IIMCT-2.jpg?v=1761205446"},{"product_id":"agilent-1260-infinity-i-hplc-g1365c-mwd-detector","title":"Agilent 1260 Infinity I HPLC G1365C MWD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1365C MWD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e1024-element photodiode array\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eData Rate\u003c\/b\u003e\u003cbr\u003eUp to 80 Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDesigned for highest optical performance, GLP compliance, and easy maintenance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRFID tags on all flow cells and UV lamps for enhanced traceability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in holmium oxide filter enables fast wavelength accuracy verification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in temperature controls improve baseline stability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigher sensitivity and selectivity with simultaneous detection of up to eight wavelengths\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow detection limits achieved through low noise electronics and patented flow cell design\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit from 1 to 16 nm allows for rapid optimization of sensitivity and linearity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eNine analytical and preparative flow cells for extensive application flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExtensive diagnostics, error detection, and display capabilities with Instant Pilot controller and Lab Advisor software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IMWD_d26a5fb7-95d0-44c5-a954-234afa28ef23.jpg?v=1779985241\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity I HPLC G1365C MWD Detector (Multiple Wavelength Detector) combines high optical performance, GLP compliance, and simplified maintenance to meet the needs of fast-paced laboratory environments. This detector boasts a data acquisition rate of up to 80 Hz, making it ideal for faster LC applications, and features long-life deuterium lamps that provide intense light across a wide wavelength range of 190 to 950 nm. Enhanced traceability is ensured through RFID tags on all flow cells and UV lamps.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe device's built-in holmium oxide filter allows for rapid verification of wavelength accuracy, while integrated temperature controls enhance baseline stability. Diagnostic signals are available for monitoring temperature and lamp voltage, ensuring consistent operation. The detector's high sensitivity and selectivity are achieved through simultaneous detection of up to eight compound-specific wavelengths, and its advanced design includes low noise front-end electronics and a patented flow cell that significantly reduces short-term noise.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith its programmable slit ranging from 1 to 16 nm, users can easily optimize sensitivity and linearity to suit various applications. The MWD offers a wide linear range for accurate quantification of primary compounds, by-products, and impurities. It also features nine analytical and preparative flow cells for maximum flexibility, complemented by extensive diagnostics, error detection, and display capabilities via the Instant Pilot controller and Agilent Lab Advisor software, making the Agilent 1260 Infinity I HPLC G1365C MWD Detector an exceptional choice for sophisticated analytical tasks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1365C MWD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nTungsten and Deuterium Lamps\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1365C MWD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 to 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.7 x 10 \n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU at 254 nm and 750 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 x 10 \n\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/h at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5 x 13.5 x 17 in. (14 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26.5 lb. (11.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 160VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1365C_MWD_Detector_-_Marshall_Scientific.pdf?v=1779985245\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1365C_MWD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985249\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2965.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474477387866,"sku":"AG-1260IMWD","price":7995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IMWD-2.jpg?v=1761205475"},{"product_id":"agilent-1260-infinity-ii-lc-system-w-vialsampler-dad","title":"Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026 DAD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 5.0 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003eUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eProvides liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDelivers several ease-of-use features, making the 1260 Infinity II a standard system for routine analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBinary Pump ensures reproducible gradients and high-performance, ideal for routine applications with UV or MS detection (Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated degasser in the Binary Pump with a volume of 0.45ml per channel helps maintain system stability and performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDiode Array Detector (DAD) enhances light transmission to near 100% efficiency, reducing baseline drift and improving peak integration\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMinimal carryover with the Vialsampler, ensuring high reliability for routine pharmaceutical, environmental, and food analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controllable via Agilent OpenLab CDS Software for seamless operation in data acquisition, analysis, and instrument control\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAllows for user configuration of standard or low delay volumes, tailoring the system to specific analytical needs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with spectral tools for comprehensive data analysis, including spectral libraries and peak purity functions\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260LCVSDADII_6b2f1f5f-75e8-4997-944a-a90347d1e7b8.jpg?v=1779985533\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar and flow range from 0.001 to 5.0 ml\/min, the 1260 Infinity II Binary Pump is suited for LC applications using conventional or superficially porous particle columns, as well as STM column technology. Gradient formation is based on a high-pressure mixing principle. Standard or low delay volumes can be easily configured by the user. The Agilent 1260 Infinity II Binary Pump offers reproducible gradients and high-performance, providing high-throughput and fast separations. The pump is suitable for routine applications, with UV or MS detection, where high speed and resolution with uncompromised data quality are required. A two-channel integrated degasser is located inside of the pump, which allows for a volume of 0.45ml per channel. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses. It houses an integrated column oven for two LC columns up to 30 mm in length. The integrated column oven paired with a sample cooler allows for temperature control from 4°C to 80°C, all within one module. Two classic trays are included with the Vialsampler, which allows for a capacity of up to 100 x 2 mL vials. The Vialsampler allows for an injection range of 0.1 to 100 µl up to a pressure of 60 MPa.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1290 Infinity II Diode Array Detector (DAD) is based on the Agilent Max-Light cartridge cell with optofluidic waveguides that improve light transmission to near 100% efficiency without sacrificing resolution caused by cell dispersions effects. With typical detector noise levels of ± 0.6 x 10\u003csup\u003e-6\u003c\/sup\u003e AU the 60 mm flow cell gives up to 10 times higher sensitivity than detectors with conventional flow cells. Any compromising refractive index and thermal effects are almost eliminated entirely, resulting in significantly less baseline drift for more reliable and precise peak integration. For fast separations, this detector has multiple wavelength and full spectral detection at sampling rates up to 240 Hz. The long-life deuterium lamp allows for the highest intensity and lowest detection limits over a wavelength range of 190 to 950 nm.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD can be fully controlled from the Agilent OpenLab CDS Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG7112B Binary Pump (With Integrated Degasser) [G7111B Quaternary Pump Upgrade Available, Please Inquire]\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7115A DAD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eG7129A Vialsampler (With Integrated Column Oven)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOpenLab CDS Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7115A Diode Array Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7112B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eIntegrated Column Oven Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7129A Vialsampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDAD Detector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Signals\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Sampling Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t240 Hz (both spectra and signals)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWith 10 mm Max-Light cartridge cell: \u0026lt; ± 3 x 10\n\t\t\t\t\u003csup\u003e-6\u003c\/sup\u003e AU at 230\/4 nm, slit width 4 nm, TC 2 s , ASTM\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWith 60 mm Max-Light cartridge cell (included): \u0026lt; ± 0.6 x 10\n\t\t\t\t\u003csup\u003e-6\u003c\/sup\u003e AU at 230\/4 nm, slit width 4 nm, TC 2 s , ASTM\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.5 x 10\n\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/h at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.0 AU (5%) at 265 nm, typically 2.5 AU (5%)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 - 400 nm in steps of 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~0.5 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMax-Light cartridge cell (high sensitivity): 60 mm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tData analysis software for spectra evaluation, including spectral libraries and peak purity functions\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tBinary Pump\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSettable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 - 5.0 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.05 - 5.0 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.3%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSettable Composition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 100%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended Compostion Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 99% or 5µl\/min per channel, whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntegrated Degassing Unit\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tNumber of channels: 2\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tInternal volume per channel: 0.45 ml\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tVialsampler\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments with 100 µl up to 60 MPa\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.25% RSD of peak areas from 5 µl to 100 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8702 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 x 2 mL vial (two classic trays included)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t18 s for draw speed 200 µl\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tEjection speed: 200 µl\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tInjection volume: 1 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarry Over\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial.\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntegrated Column Oven\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient +4°C to 80°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t2°C - 6°C at a setpoint of 4°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t2 columns of up to 30 mm length\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_Vialsampler___DAD_-_Marshall_Scientific.pdf?v=1779985537\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_Vialsampler___DAD_Manual_-_Marshall_Scientific.pdf?v=1779985542\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2620.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ No Additional Detector Needed","offer_id":42474477584474,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ Agilent 1260 Infinity II HPLC G7162A RID Detector","offer_id":42474477617242,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ Agilent 1260 Infinity II HPLC G7165A MWD Detector","offer_id":42474477650010,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ No Additional Detector Needed","offer_id":42474477682778,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ Agilent 1260 Infinity II HPLC G7162A RID Detector","offer_id":42474477715546,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ Agilent 1260 Infinity II HPLC G7165A MWD Detector","offer_id":42474477748314,"sku":"AG-1260LCVSDADII","price":46995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260LCVSDADII-2.jpg?v=1761205508"},{"product_id":"agilent-1260-infinity-ii-lc-system-w-vialsampler-vwd","title":"Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026 VWD","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (VWD)\u003c\/b\u003e\u003cbr\u003e190 to 600 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Rate Range\u003c\/b\u003e\u003cbr\u003e0.001 to 5.0 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003eUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eProvides liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDelivers several ease-of-use features, making the 1260 Infinity II a standard system for routine analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBinary Pump ensures reproducible gradients and high-performance, ideal for routine applications with UV or MS detection (Quaternary Pump available, please inquire)\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated degasser in the Binary Pump with a volume of 0.45ml per channel helps maintain system stability and performance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eVariable Wavelength Detector offers dual-wavelength detection with low noise\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMinimal carryover with the Vialsampler, ensuring high reliability for routine pharmaceutical, environmental, and food analyses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFully controllable via Agilent OpenLab CDS Software for seamless operation in data acquisition, analysis, and instrument control\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAllows for user configuration of standard or low delay volumes, tailoring the system to specific analytical needs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEquipped with spectral tools for comprehensive data analysis, including spectral libraries and peak purity functions\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260LCVSDADII_6b2f1f5f-75e8-4997-944a-a90347d1e7b8.jpg?v=1779985533\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD provides a liquid chromatograph offering ultra fast and high resolution separation capability for consistently accurate results. The 1260 Infinity II LC System delivers several ease-of-use features, making it a standard system for routine analysis. With an operating pressure of up to 600 bar and flow range from 0.001 to 5.0 ml\/min, the 1260 Infinity II Binary Pump is suited for LC applications using conventional or superficially porous particle columns, as well as STM column technology. Gradient formation is based on a high-pressure mixing principle. Standard or low delay volumes can be easily configured by the user. The Agilent 1260 Infinity II Binary Pump offers reproducible gradients and high-performance, providing high-throughput and fast separations. The pump is suitable for routine applications, with UV or MS detection, where high speed and resolution with uncompromised data quality are required. A two-channel integrated degasser is located inside of the pump, which allows for a volume of 0.45ml per channel. \n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses. It houses an integrated column oven for two LC columns up to 30 mm in length. The integrated column oven paired with a sample cooler allows for temperature control from 4°C to 80°C, all within one module. Two classic trays are included with the Vialsampler, which allows for a capacity of up to 100 x 2 mL vials. The Vialsampler allows for an injection range of 0.1 to 100 µl up to a pressure of 60 MPa.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II Variable Wavelength Detector (VWD) is the most sensitive and fastest detector in its class. The detector features time-programmable wavelength switching provides sensitivity and selectivity for your applications. More sample information can be acquired in the dual wavelength mode. Low detector noise (\u0026lt; ± 2.5 AU) and baseline drift (\u0026lt; 1 x 10^-4 AU\/h) facilitates precise quantification of trace levels components. High productivity can be achieved with fast analysis at up to 120 Hz data rates.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; DAD can be fully controlled from the Agilent OpenLab CDS Software, which allows for user-friendly operation in data acquisition, analysis, instrument control, automation, and more.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThis Agilent system is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nG7112B Binary Pump (With Integrated Degasser) [G7111B Quaternary Pump Upgrade Available, Please Inquire]\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nG7114A VWD Detector\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eG7129A Vialsampler (With Integrated Column Oven)\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eWindows 11 Professional 64-Bit Data Station with Flatscreen Monitor\u003c\/span\u003e\n\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOpenLab CDS Software Installed\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nCan\/Crossover Cables\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent Lan Interface Card Built-In\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nSolvent Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n4 x Bottles, Caps and Solvent Filters\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nNew Stainless Steel Capillaries\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n1\/4\" Wrench \u0026amp; Mobile Phase Priming Syringe\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nWaste Tubing\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAll Power Cords\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nAgilent 4 Peak Test w\/ Lab Advisor Diagnostics Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"agilent-tests\"\u003e\n\t\t\u003cspan class=\"agilent-tests-title\"\u003eBelow is a List of Diagnostic Tests Performed On This System\u003c\/span\u003e\u003cbr\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7114A Variable Wavelength Detector Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eFilter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.\u003c\/li\u003e\n\t\t\t\u003cli\u003eDark Current Test: The test measures the dark current from the detector optic.\u003c\/li\u003e\n\t\t\t\u003cli\u003eHolmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter. The spectrum is evaluated for peaks at different wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.\u003c\/li\u003e\n\t\t\t\u003cli\u003eWavelength Intensity Test: The test confirms the accuracy of wavelengths measured.\u003c\/li\u003e\n\t\t\t\u003cli\u003e Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7112B Binary Pump Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003ePressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.\u003c\/li\u003e\n\t\t\t\u003cli\u003eLeak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eIntegrated Column Oven Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eThermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eG7129A Vialsampler Diagnostic Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e Injector Steps: Performs each movement of the sampling sequence under manual control. This is useful for confirming autosampler functionality.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003cspan class=\"agilent-tests-header\"\u003eSystem Tests:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e4 Peak Test (Isocratic Standard): Standard test published by Agilent to confirm complete functionality of the Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD.\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVWD Detector\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpecification\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.25 x 10^-5 AU, at 230 nm (single wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.80 x 10^-5 AU, at 230 nm and 254 nm (dual wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 x 10^-4 AU\/h at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.5 AU upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5nm typical over whole wavelength range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp on\/off\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 14 µl volume, 10 mm cell path length and 40 bar (588 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStop-flow wavelength scan\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"show-hidden-table\"\u003e\nClick Here to View More Specifications for the Agilent 1260 Infinity II LC System w\/ Vialsampler \u0026amp; VWD\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"hidden-table\"\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tBinary Pump\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHydraulic System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSettable Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.001 - 5.0 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended Flow Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t0.05 - 5.0 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t≤ 0.07% RSD or ≤ 0.02 min SD, whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 1% or 10 µl\/min, whichever is greater, pumping degassed H2O at 10 MPa (100 bar)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tUp to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.3%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCompressibility Compensation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tDelay Volume\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t600 - 900 µl, dependent on back pressure; measured with water at 1 ml\/min (water\/caffeine tracer)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSettable Composition Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 100%\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRecommended Compostion Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 - 99% or 5µl\/min per channel, whichever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.15% RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntegrated Degassing Unit\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tNumber of channels: 2\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tInternal volume per channel: 0.45 ml\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tVialsampler\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.1 - 100 µl in 0.1 µl increments with 100 µl up to 60 MPa\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u0026lt; 0.25% RSD of peak areas from 5 µl to 100 µl\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8702 psi)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.2 - 5 cp\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t100 x 2 mL vial (two classic trays included)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\t18 s for draw speed 200 µl\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tEjection speed: 200 µl\/min\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tInjection volume: 1 µl\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tCarry Over\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial.\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tMulticolumn Thermostat\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tSpecification\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Range\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tAmbient -10°C to 85°C (minimum 4°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Stability\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.1°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Accuracy\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t± 0.5°C (with calibration for 40°C)\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tTemperature Precision\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t0.05°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIndependent Temperature Zones\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t2 in single device\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tColumn Capacity\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t4 columns of up to 300 mm length plus InfinityLab Quick-Connect fittings or pre-column The number of precolumn Quick-Connect Heat Exchangers is scalable - each column can be equipped with individual heat exchanger for best performance 4-column selector valve is available to access each column without replumbing\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHeat-Up \/ Cool-Down Time\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t5 min from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 min from 40°C to 20°C\u003cbr\u003e\u0026lt; 25 min from 25°C to 85°C\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\t\u003ctable\u003e\n\t\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\t\u003ccenter\u003e\n\t\t\t\t\u003cp\u003e\n\t\t\t\t\tComputer Specifications\n\t\t\t\t\u003c\/p\u003e\n\t\t\t\t\u003c\/center\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tProcessor\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tIntel Core I5-8500 CPU\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tRAM\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t32.0 GB\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tHard Drive\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\t500GB Internal SSD\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tOperating System\n\t\t\t\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\tWindows 11 Professional, 64-bit\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003c\/tbody\u003e\n\t\t\u003c\/table\u003e\n\t\u003c\/div\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_LC_System_with_Vialsampler___VWD_-_Marshall_Scientific.pdf?v=1779985549\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_Binary_LC_System_Manual_-_Marshall_Scientific.pdf?v=1779985553\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2785.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"windows11\"\u003e\u003c\/span\u003e","brand":"My Store","offers":[{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ No Additional Detector Needed","offer_id":42474477813850,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ Agilent 1260 Infinity II HPLC G7162A RID Detector","offer_id":42474477846618,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7112B Binary Pump (With Integrated Degasser) \/ Agilent 1260 Infinity II HPLC G7165A MWD Detector","offer_id":42474477879386,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ No Additional Detector Needed","offer_id":42474477912154,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ Agilent 1260 Infinity II HPLC G7162A RID Detector","offer_id":42474477944922,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true},{"title":"Agilent 1260 Infinity II G7111B Quaternary Pump (With Integrated Degasser) [Additional $3,295.00] \/ Agilent 1260 Infinity II HPLC G7165A MWD Detector","offer_id":42474477977690,"sku":"AG-1260LCVSVWDII","price":44730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260LCVSVWDII-2.jpg?v=1761205543"},{"product_id":"agilent-1260-infinity-ii-hplc-g7167a-multisampler","title":"Agilent 1260 Infinity II HPLC G7167A Multisampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7167A Multisampler\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e 0.1 to 100 µL (Optional 20 to 40µL)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Precision\u003c\/b\u003e\u003cbr\u003e\u0026lt; 0.2 % RSD or SD \u0026lt; 10 nL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Pressure \u003c\/b\u003e\u003cbr\u003e800 bar\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eMultipurpose autosampler designed for handling both vials and microplates in HPLC applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapable of injecting at pressures up to 600 or 800 bar, suitable for a variety of analytical needs\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompact module with a high capacity of up to 6,144 samples within the footprint of an Agilent LC stack\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures a unique dual-needle design to reduce cycle times by overlapping sample runs and injection cycles\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMultiwash capability significantly reduces carryover to less than 9 ppm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOffers flexible injection range from 0.1 – 100 µL in 0.1 µL increments, with optional configurations available\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomated internal robotics for seamless movement of microtiter plates and other sample containers\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eQuick injection cycle time of less than 10 seconds under standard conditions, enhancing throughput and efficiency\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/ag-1260mls_45f409fa-5580-4d6c-8313-f39f620a0cf2.jpg?v=1779985484\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\nThe Agilent 1260 Infinity II HPLC G7167A Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Agilent LC stack. The 1260 Infinity II Multisampler is optimized for highest flexibility. The unique dual-needle design enables cycle times to be reduced by overlapping sample runs and injection cycles. The multiwash capability reduces carryover to less than 9 ppm.\n\t\u003cbr\u003e\u003cbr\u003eThe G7167A's internal robotics allow for seamless automation, moving microtiter plates and other sample containers from the sample hotel to the central workspace for sample processing steps and injections. The Agilent unique dual-needle setup also enhances flexibility by providing two differently optimized injectors in a single instrument. Users for example can optimize one path for large volume injections and the other for low delay volumes. Lights are featured on each sample drawer to easily indicate loading status, current activity, and accessibility for instant information.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7167A Multisampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n2 x Sample Drawers\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7167A Multisampler Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDefault: 0.1 – 100 µL in 0.1 µL increments;\n\t\t\t\u003cbr\u003eoptional: 20 µL or 40 µL (using 100 µL analytical\u003cbr\u003ehead)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInjection Precision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt;0.2 % RSD or SD \u0026lt;10 nL, whatever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInjection Linearity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.9999 in the range of 0.1 – 100 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPressure Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tUp to 800 bar\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Viscosity Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t0.2 to 5.0 cP\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t1H Drawer: up to 8 drawers and 16 positions; Shallow well plates (MTP)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t2H Drawer: up to 4 drawers and 8 positions; MTP, deep well plates, vials, Eppendorf\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t3H Drawer: up to 2 drawers and 4 positions; MTP, deep well plates, vials up to 6 mL, Eppendorf\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInjection Cycle Time\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt;10 s using following standard conditions:\n\t\t\t\t\u003cbr\u003eDefault draw speed: 100 µL\/min\u003cbr\u003eDefault eject speed: 400 µL\/min\u003cbr\u003eInjection volume: 1 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tCarryover\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt;0.003 % (30 ppm) Multisampler Standard and\n\t\t\t\t\u003cbr\u003eDual Needle\u003cbr\u003e\u0026lt;0.0009 % (9 ppm) Multisampler Multiwash\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMultiwash\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOuter needle wash and seat backflush for carryover reduction with up to 3 different solvents\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (H x W x D)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t12.6 x 15.6 x 18.4 in. (32 x 39.6 x 46.8 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t48.5 lb. (22 kg.)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 - 240V, 50\/60Hz, 180VA\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7167A_Multisampler_-_Marshall_Scientific.pdf?v=1779985488\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7167A_Multisampler_Manual_-_Marshall_Scientific.pdf?v=1779985493\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2436.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474478010458,"sku":"AG-1260MLS","price":21985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260MLS-2.jpg?v=1761205575"},{"product_id":"agilent-1260-infinity-hplc-g1379b-micro-vacuum-degasser","title":"Agilent 1260 Infinity HPLC G1379B Micro Vacuum Degasser","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity HPLC G1379B Micro Vacuum Degasser\u003c\/h1\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity HPLC G1379B Micro Vacuum Degasser comprises a 4-channel vacuum container, including 4 micro structured membranes, and a vacuum pump. When the micro vacuum degasser is switched on, the control circuit turns on the vacuum pump, which is operated with constant speed and voltage generates a partial vacuum in the vacuum container. The pressure is measured by a pressure sensor. The micro vacuum degasser maintains the partial vacuum with the help of a controlled leak in the degasser’s proportional valve and by varying size of the controlled leak within the proportional valve, depending on the signal from the pressure sensor.\u003cbr\u003e\u003cbr\u003eThe LC pump draws the solvents from their bottles through the special plastic membranes of the vacuum container. As the solvents pass through the vacuum chambers any dissolved gas in the solvents permeates through the membranes into the vacuum container. The solvents will be almost completely degassed when leaving the outlets of the micro vacuum degasser.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity HPLC G1379B Micro Vacuum Degasser includes:\u003cul\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity HPLC G1379B Micro Vacuum Degasser Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 to 5 ml\/min per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNumber of Channels\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t4\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInternal Volume per Channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tTypically 1ml per channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaterials in Contact with Solvent\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tPTFE, FEP, PEEK\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t1 to 14\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRS-232 Output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tFor diagnostic purposes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (H x W x D)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t16 lb. (7 kg.)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 - 240V, 50\/60Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_G1379B_Micro_Vacuum_Degasser_-_Marshall_Scientific.pdf?v=1779985078\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_G1379B_Micro_Vacuum_Degasser_Manual_-_Marshall_Scientific.pdf?v=1779985082\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2446.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474478043226,"sku":"AG-1260MVD","price":2695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260MVD-2.jpg?v=1761205598"},{"product_id":"agilent-1260-infinity-ii-hplc-g7111b-quat-pump","title":"Agilent 1260 Infinity II HPLC G7111B Quat Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7111B Quat Pump\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Accuracy\u003c\/b\u003e\u003cbr\u003e ± 1% or 10 µl\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSettable Flow Range\u003c\/b\u003e\u003cbr\u003e\tSet points 0.001 to 10 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Range \u003c\/b\u003e\u003cbr\u003e0.2 to 10.0 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFeatures a dual piston in-series design with servo-controlled variable stroke drive for precise solvent delivery\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports low-pressure quaternary gradient mixing with access to up to four solvents\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDelivers virtually pulse-free and stable solvent flow with adjustable stroke volume\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHandles pressures up to 600 bar for high-resolution applications with smaller particle size columns\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIncludes an integrated 4-channel vacuum degasser for efficient solvent degassing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eWide flow range from 0.001 to 10 mL\/min, supporting both analytical and semi-preparative applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eConstructed with durable materials like stainless steel and PEEK for longevity and demanding applications\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260QUAT_8a4b0eea-3908-4dd3-a1ee-c88b0a38a154.jpg?v=1779985356\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7111B Quat Pump is an advanced solution designed to enhance analytical performance with exceptional flexibility and precision. Equipped with a dual piston in-series hydraulic system, servo-controlled variable stroke drive, and floating pistons, this pump delivers virtually pulse-free, stable, and well-mixed solvent flows. Its wide settable flow range of 0.001 to 10 mL\/min and maximum operating pressure of up to 60 MPa (600 bar) ensure compatibility with high-resolution applications using smaller particle size columns. Whether you are conducting routine analysis or developing sophisticated methods, the 1260 Infinity II Quat Pump offers robust capabilities tailored for diverse fields, including food safety, environmental testing, and pharmaceuticals.\n\t\u003cbr\u003e\u003cbr\u003e\n\tEngineered for efficiency and longevity, the Agilent 1260 Infinity II G7111B integrates a low-pressure quaternary mixing gradient system, supporting up to four solvents for streamlined analysis. Its high-speed proportioning valve facilitates precise blending, while an integrated degasser with four channels ensures optimal system performance by reducing gas interference. The pump’s versatility extends to its wide pH range (1.0 to 12.5), accommodating a variety of mobile phases, and its durable materials, including stainless steel and PEEK, guarantee extended operational life with minimal maintenance. Compact yet powerful, with dimensions of 7.1 x 15.6 x 17.2 inches and a weight of 38.8 pounds, this pump is ideal for modern labs prioritizing performance, reliability, and adaptability.  \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7111B Quat Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLeak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7111B Quat Pump Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual piston in series pump with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSet points 0.001 to 10 ml\/min, in 0.001 ml\/min increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.2 to 10.0 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t≤ 0.07% RSD, or ≤ 0.02 min SD whatever is greater, based on retention time at constant room temperature\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1% or 10 µl\/min, whatever is greater, pumping degassed H\n\t\t\t\u003csub\u003e2\u003c\/sub\u003eO at 10 MPa (100 bar)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating range up to 60 MPa (600 bar, 8700 psi) up to 5 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOperating range up to 20 MPa (200 bar, 2950 psi) up to 10 ml\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2% amplitude (typically \u0026lt; 1.0%) or \u0026lt; 0.3 MPa (3 bar, 44 psi), whatever is greater, at 1 ml\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 145 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUser-selectable, based on mobile phase compressibility\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.0 to 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary high-speed proportioning valve\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t600 to 900 µl, dependent on back pressure; measured with water at 1 ml\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tComposition Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 to 100% in 0.1% increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.2% RSD or \u0026lt; 0.04 min SD, whatever is greater, at 1 ml\/min; based on retention time at constant room temperature\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIntegrated Degasser\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tNumber of channels: 4\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInternal volume per channel: 1.5 ml\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t7.1 x 15.6 x 17.2 in. (18 x 39.6 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t38.8 lb. (17.6 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100 to 240 V, 50\/60 Hz, 80 VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7111B_Quat_Pump_-_Marshall_Scientific.pdf?v=1779985360\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7111B_Quat_Pump_Manual_-_Marshall_Scientific.pdf?v=1779985364\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2856.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474479419482,"sku":"AG-1260QUAT","price":8650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260QUAT-2.jpg?v=1761205655"},{"product_id":"agilent-1260-infinity-i-hplc-g1362a-rid-detector","title":"Agilent 1260 Infinity I HPLC G1362A RID Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1362A RID Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRefractive Index Range\u003c\/b\u003e\u003cbr\u003e1.00 to 1.75 RIU, calibrated\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003cbr\u003e± 600 x 10\u003csup\u003e-6\u003c\/sup\u003e RIU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDrift\u003c\/b\u003e\u003cbr\u003e\u0026lt; 200 x 10\u003csup\u003e-9\u003c\/sup\u003e RIU\/h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eSuitable for entry-level UHPLC and HPLC applications requiring differential refractive index detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDifferential refractometer design with separate sample and reference cells in a single flow cell\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMeasures deflection of light beam caused by differences in refractive index between liquids\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRapid equilibration times and stable baselines enhance reliability in analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIdeal for analyzing carbohydrates, triglycerides, organic acids, and pharmaceutical excipients\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePreferred choice for polymer characterization using gel permeation and size exclusion chromatography\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptics temperature control ranges from 5°C above ambient to 55°C for optimal operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFeatures automatic purging and programmable purge times for the reference flow cell\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic light intensity adjustment compensates for lamp degradation and flow cell staining\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMinimum baseline noise provides excellent sensitivity and low detection limits\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRecycle valve maintains system at operating conditions, reducing warm-up times and solvent waste\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptimal data capture rate at 37 Hz to support rapid analyses and high-throughput needs\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260RID_26770427-22fe-4351-b094-d7e0b1e8c028.jpg?v=1779985217\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1362A RID Detector is an HPLC refractive index detector (RID) detector that provides excellent performance for entry-level UHPLC and HPLC differential refractometer (DRI) experiments. This detector is a differential refractometer that measures the deflection of a light beam due to the difference in refractive index between the liquids in the sample and reference cells of a single flow cell. A beam of light from the lamp passes through a flow cell which is separated diagonally into sample and reference cells. At the rear of the flow cell a mirror reflects the light back through the flow cell and via a zero glass, which affects the path of the light beam, to the light receiver. The light receiver has two diodes each of which produces an electrical current proportional to the amount of light that falls upon it. Rapid equilibration times and stable baselines make it easy to analyze carbohydrates, triglycerides, organic acids, and pharmaceutical excipients. The Agilent 1260 Infinity HPLC G1362A RID Detector is the detector of choice for polymer characterization using gel permeation chromatography (GPC) and size exclusion chromatography (SEC).\u003cbr\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1362A RID Detector also features optimized light levels, automatically adjusting the light intensity to compensate for lamp degradation and flow cell staining. Users can conduct automatic purging of the reference flow cell as well using programmable purge and wait times. This G1362A RID Detector features minimum baseline noise for excellent sensitivity and low limits of detection. Users may also utilize the recycle valve to keep the system at operating conditions, avoiding warm-up wait times and saving solvents.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1362A RID Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1362A RID Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tRefractive Index\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tRefractive Index Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t1.00 to 1.75 RIU, calibrated\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMeasurement Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t± 600 x 10^-6 RIU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tOptics Temperature Control\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t5°C above ambient to 55°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tSample Cell\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tVolume 8 µL, maximum pressure 5 bar (0.5 Mpa), maximum flow rate 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tValves\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tAutomatic purge and automatic solvent recycle\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tVolumes\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInlet port to sample cell: 62 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInlet port to outlet port: 590 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tLiquid Contact Materials\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t316 stainless steel, PTFE, and quartz glass\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tpH Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2.3 to 9.5\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tShort Term Noise\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 2.5 x 10^-9 RIU\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDrift\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 200 x 10^-9 RIU\/h\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tMaximum Data Rate\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t37 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetector Zero\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomatic zero before analysis\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (H x W x D)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t7 x 13.5 x 17 in. (18 x 34.5 x 43.5 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t38 lb. (17 kg.)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100 - 240V, 50\/60Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_G1362A_RID_Detector_-_Marshall_Scientific.pdf?v=1779985221\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_HPLC_G1362A_RID_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985225\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2445.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474480271450,"sku":"AG-1260RID","price":11995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260RID-2.jpg?v=1761205702"},{"product_id":"agilent-1260-infinity-ii-hplc-g7162a-rid-detector","title":"Agilent 1260 Infinity II HPLC G7162A RID Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7162A RID Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e Refractive Index\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eRefractive Index Range\u003c\/b\u003e\u003cbr\u003e1.00 to 1.75 RIU, calibrated\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDrift \u003c\/b\u003e\u003cbr\u003e\u0026lt; 200 x 10\n\t\t\t\u003csup\u003e-9\u003c\/sup\u003e RIU\/hr\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003ePrecise optical zeroing via software or manual adjustment for enhanced accuracy\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOptics temperature control from 5°C above ambient to 55°C to maintain stability during analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e8 µL sample cell volume with a maximum pressure of 5 bar (0.5 MPa) for efficient sample handling\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic purge and solvent recycle valves to streamline operation and minimize waste\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMinimal short-term noise (\u0026lt; ± 1.25 x 10⁻⁹ RIU) for reliable and precise measurements\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic detector zeroing before analysis ensures consistent and accurate results\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLiquid contact materials include 316 stainless steel, PTFE, and quartz glass for chemical compatibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eMaximum data rate of 74 Hz allows high-speed acquisition of analytical data\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260RIDII-3_4a96164a-11e3-4514-9e7f-45a65f4f030e.jpg?v=1779985458\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7162A RID Detector (Refractive Index Detector) is expertly designed for the precise and reliable analysis of non-UV absorbing substances, making it ideal for carbohydrates, lipids, and polymers. This detector is also perfectly suited for specialized applications like gel permeation chromatography (GPC) and size exclusion chromatography (SEC), offering a refractive index range of 1.00 to 1.75 RIU. With its high sensitivity and robust detection capabilities, the 1260 Infinity II RID achieves an outstanding reproducibility rate of only 0.1% RSD.\n\t\u003cbr\u003e\u003cbr\u003e\n\tKey features include precise temperature control, ranging from Ambient +5°C to 55°C, which minimizes baseline drift and optimizes response rates for various compounds. The detector's automatic light level adjustment not only compensates for lamp degradation but also reduces maintenance needs by regulating flow cell staining. It includes an integrated solvent recycle valve which supports solvent recycling between runs, enhancing operational efficiency.\n\t\u003cbr\u003e\u003cbr\u003e\n\tFor ease of maintenance and operation, the 1260 Infinity II RID features convenient front access to flow connections and valves, automatic baseline zeroing, and programmable cell purging. The detector also provides Early Maintenance Feedback (EMF) for timely maintenance notifications and a continuous tracking system for reference flow cell purging with user-settable limits. Troubleshooting is facilitated through integrated diagnostic tools and an automatic offset adjustment feature that simplifies the detection and quantification of negative peaks and allows for the easy inversion of peaks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7162A RID Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7162A RID Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tRefractive Index\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRefractive Index Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.00 to 1.75 RIU, calibrated\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMeasurement Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 600 x 10\n\t\t\t\u003csup\u003e-6\u003c\/sup\u003e RIU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptical Zeroing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDigitally via software, manually via set screw\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tOptics Temperature Control\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5°C above ambient to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tVolume 8 µL, maximum pressure 5 bar (0.5 Mpa), maximum flow rate 5 mL\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tValves\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomatic purge and automatic solvent recycle\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tVolumes\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInlet port to sample cell: 62 µL\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tInlet port to outlet port: 590 µL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLiquid Contact Materials\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t316 stainless steel, PTFE, and quartz glass\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2.3 to 9.5\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 1.25 x 10\n\t\t\t\u003csup\u003e-9\u003c\/sup\u003e RIU\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 200 x 10\n\t\t\t\u003csup\u003e-9\u003c\/sup\u003e RIU\/hr\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t74 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetector Zero\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomatic zero before analysis\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDimensions (H x W x D)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t7.1 x 15.6 x 17.2 in. (18 x 39.6 x 43.6 cm)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tWeight\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t32.4 lb. (14.7 kg.)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t100-240V, 50\/60Hz, 80VA\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7162A_RID_Detector_-_Marshall_Scientific.pdf?v=1779985462\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7162A_RID_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985467\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2787.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474480402522,"sku":"AG-1260RIDII","price":13995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260RIDII-2.jpg?v=1761205731"},{"product_id":"agilent-1260-infinity-i-hplc-g1312b-binary-pump","title":"Agilent 1260 Infinity I HPLC G1312B Binary Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1312B Binary Pump\u003c\/h1\u003e\n\t\u003cbr\u003e\n\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Range\u003c\/b\u003e\u003cbr\u003e 0.05 - 5.0 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Operating Range\u003c\/b\u003e\u003cbr\u003e\t\n\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Precision \u003c\/b\u003e\u003cbr\u003e≤ 0.07% RSD or 0.02 min SD, whatever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDual-piston in-series design with servo-controlled variable stroke drive\u003c\/li\u003e\n  \u003cli\u003eGear and ball screw-driven floating pistons ensure consistent performance\u003c\/li\u003e\n  \u003cli\u003eHigh-pressure binary mixing for precise gradient formation\u003c\/li\u003e\n  \u003cli\u003eStandard and low delay volume configurations available for optimized response\u003c\/li\u003e\n  \u003cli\u003eComposition range settable from 0 to 100% with high accuracy and precision\u003c\/li\u003e\n  \u003cli\u003ePredefined compressibility compensation enhances solvent delivery stability\u003c\/li\u003e\n  \u003cli\u003eCompatible with Agilent ChemStation, EZchrom, and MassHunter software\u003c\/li\u003e\n  \u003cli\u003eRecommended pH range from 1.0 to 12.5 for versatile solvent compatibility\u003c\/li\u003e\n  \u003cli\u003eIntegrated purge valve with PTFE frit for easy system priming\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-BIN1260-7T_cf2a6e20-3739-4d15-8bce-006725e59062.jpg?v=1779985121\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\nThe Agilent 1260 Infinity I HPLC G1312B Binary Pump is based on a two-channel, dual-piston in-series design which comprises all essential functions that a solvent delivery system has to fulfill. Metering of solvent and delivery to the high-pressure side are performed by two pump assemblies which can generate pressure up to 600 bar. \n\t\t\u003cbr\u003e\u003cbr\u003eEach channel comprises a pump assembly including pump drive, pump head, active inlet valve with replaceable cartridge, and outlet valve. The two channels are fed into a low-volume mixing chamber which is connected via a restriction capillary coil to a damping unit and a mixer. A pressure sensor monitors the pump pressure. A purge valve with integrated PTFE frit is fitted to the pump outlet for convenient priming of the pumping system. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. The pump is capable of delivering flow in the range of 0.1 to 5 mL\/min.\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1312B Binary Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Leak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1312B Binary Pump Specifications\u003c\/h2\u003e\n\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003ctable class=\"MsoTableGrid\" style=\"background-color: rgb(255, 255, 255); font-size: 16px;\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHydraulic System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tTwo dual piston in series pumps with servo-controlled variable stroke drive, power transmission by gears and ball screws, floating pistons\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSetable Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t0.001 - 5 mL\/min, in 0.001 mL\/min increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt; line-height: normal;\"\u003e\n\t\t\t\t0.05 - 5.0 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t≤ 0.07% RSD or  0.02 min SD, whatever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tFlow Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 1% or 10 µl\/min, what ever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Operating Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t0 - 60 MPa (0 - 600 bar, 0 - 8,700 psi) up to 5 mL\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tPressure Pulsation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressures \u0026gt; 1 MPa (10 bar, 147 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tCompressibility Compensation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tPre-defined, based on mobile phase compressibility\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tRecommended pH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\t1.0 - 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tGradient Formation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tHigh-pressure binary mixing\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tDelay Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\tStandard delay volume configuration: 600 - 800 µl, (includes 400 µl mixer), dependent on back pressure\n\t\t\t\u003cbr\u003e\u003cbr\u003eLow delay volume configuration: 120 µl\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tSettable range: 0 to 100%\n\t\t\t\u003cbr\u003e\u003cbr\u003eRecommended Range: 1 to 99% or 5 µl\/min per channel, whatever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Precision\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u0026lt; 0.15 % RSD or \u0026lt; 0.04 min SD, whatever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tComposition Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t± 0.35% absolute, at 2 mL\/min, at 10 MPa (100 bar)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tControl\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tAgilent ChemStation, EZchrom, MassHunter\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t7 x 13.5 x 17 in. (18 x 34.5 x 43.5 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t34 lbs. (15.5 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"border-right-width: 1pt; border-bottom-width: 1pt; border-top-style: none; border-left-style: none; border-right-color: windowtext; border-bottom-color: windowtext; padding: 0in 5.4pt; width: 239.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t100 - 240 VAC, 50\/60Hz, 74W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1312B_Binary_Pump_-_Marshall_Scientific.pdf?v=1779985125\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_G1312B_Binary_Pump_Manual_-_Marshall_Scientific.pdf?v=1779985130\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2355.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474499244122,"sku":"AG-BIN1260","price":6995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-BIN1260-2.jpg?v=1761207269"},{"product_id":"agilent-1260-infinity-i-hplc-g1316a-column-compartment","title":"Agilent 1260 Infinity I HPLC G1316A Column Compartment","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1316A Column Compartment\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Range\u003c\/b\u003e\u003cbr\u003e 10°C below ambient to 80°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Stability\u003c\/b\u003e\u003cbr\u003e± 0.15°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eTemperature Accuracy \u003c\/b\u003e\u003cbr\u003e± 0.8°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t \u003cli\u003eAccommodates up to three 30 cm columns for flexible method development\u003c\/li\u003e\n  \u003cli\u003eDual heat exchangers enable efficient solvent pre-heating\u003c\/li\u003e\n  \u003cli\u003eAutomated column identification module supports GLP compliance\u003c\/li\u003e\n  \u003cli\u003eCompact design integrates easily into Agilent 1260 Infinity HPLC stacks\u003c\/li\u003e\n  \u003cli\u003eFast warm-up and cool-down reduces downtime between runs\u003c\/li\u003e\n  \u003cli\u003eIncludes CAN cable for seamless communication within the HPLC system\u003c\/li\u003e\n  \u003cli\u003eBuilt-in safety features include leak detection and shutdown signaling\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1316A_c4b70d23-d4fb-45d8-9233-6e3e96bb0d77.jpg?v=1779985162\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe Agilent 1260 Infinity I HPLC G1316A Column Compartment is built with two heat exchangers for\nsolvent pre-heating, automated column identification module and CAN cable. The compartment’s compact size conveniently fits into a single Agilent 1260 Infinity HPLC stack. The G1316A offers a temperature range of \n\t\t\u003co:p\u003e\u003c\/o:p\u003e10° below ambient to 80° C and temperature stability of \u003cspan\u003e± 0.15°C. The Agilent G1316A has a column capacity of three 30 centimeter columns and can utilize a temperature accuracy of \u003c\/span\u003e\u003cspan\u003e± 0.8°C. The warm up\/cool down of the G1316A is \u003c\/span\u003e\u003cspan\u003e5 mins from ambient to 40°C. This column compartment features many safety and maintenance protocols, such as extensive diagnostics, error detection and display, leak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas.\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1316A Column Compartment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1316A Column Compartment includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Switching Valve\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nThermostat Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1316A Column Compartment Specifications\u003c\/h2\u003e\n\t\u003cb\u003e\u003c\/b\u003e\n\t\u003ctable class=\"MsoTableGrid\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-color: windowtext; border-width: 1pt; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tTemperature Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-style: none; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t10°C below ambient to 80°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tTemperature Stability\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t± 0.15°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tTemperature Accuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t± 0.8°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tColumn Capacity\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tThree 30 cm columns\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-top-style: none; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\tWarm-Up\/Cool-Down Time\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd style=\"width: 239.4pt; border-top-style: none; border-left-style: none; border-bottom-color: windowtext; border-bottom-width: 1pt; border-right-color: windowtext; border-right-width: 1pt; padding: 0in 5.4pt;\" width=\"319\" valign=\"top\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t5 mins from ambient to 40°C\n\t\t\t\t\u003cbr\u003e10 minutes from 40°C to 20°C\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan style=\"font-size: 11pt; font-family: Calibri, sans-serif;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cb\u003e \u003c\/b\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G1316A_Manual_-_Marshall_Scientific.pdf?v=1779985167\" target=\"_blank\"\u003e\u003cbr\u003eAgilent 1260 Infinity HPLC G1316A Column Compartment\u003c\/a\u003e\u003cbr\u003e\u003ccenter\u003e\u003cbr\u003e\u003c\/center\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G1316A_-_Marshall_Scientific.pdf?v=1779985171\" target=\"blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/marshdoc_6a60f823-6a0b-4621-bdd8-8e71c369a0fb.png?v=1779984276\"\u003eClick Here to View the Technical Specs for the Agilent 1260 G1316A Column Compartment\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2265.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474502389850,"sku":"AG-ColC1260","price":3495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-ColC1260-2.jpg?v=1761207392"},{"product_id":"agilent-1260-infinity-i-hplc-g4212b-dad-detector","title":"Agilent 1260 Infinity I HPLC G4212B DAD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G4212B Diode Array Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 to 640 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eLight Source\u003c\/b\u003e\u003cbr\u003eDeuterium Lamp\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDrift \u003c\/b\u003e\u003cbr\u003e\u0026lt; 0.5 × 10^-3 AU\/hr at 230 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003e1024-element photodiode array for high-resolution detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLinear absorbance range \u0026gt; 2.0 AU at 265 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eWavelength accuracy of ± 1 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFixed 4 nm slit width for optimized resolution\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e80 Hz signal and spectra data rate for ultra-fast HPLC analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with Max-Light Cartridge Cells for versatile applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExtensive diagnostics with error and leak detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eGLP features include early maintenance feedback and wavelength verification\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G4212_1278ed6e-34cd-4a94-8aff-29034af5b601.jpg?v=1779985269\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G4212B DAD Detector verifies separation\nquality with peak purity, multiple signals, and spectral libraries during analytical quantification, offering an extended wavelength range with the\nhighest sensitivity. The diode array detector allows for automated\nwavelength verification for performance tracking. The Agilent 1260’s temperature\nmanagement system ensures optimum baseline stability, even under rough ambient\nconditions. \n\t\t\u003cspan style=\"background-color: initial;\"\u003eThe DAD also provides greatly enhanced sensitivity as well as building upon baseline stability, using a cartridge cell system with optofluidic waveguides.\u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e This detector features superb illumination using combined deuterium\nand tungsten lamps for the highest intensity and lowest detection limit from\n190 to 640 nm, 1024 diodes and a fixed 4-nm slit. The fixed 4-nm slit allows for rapid optimization of sensitivity, linearity, and spectral resolution to provide optimum incident light conditions. Also featured in the Agilent 1260 Infinity G4212B is an 80 Hz data acquisition and sampling rate, keeping up with the analysis of ultra-fast HPLC.\n\t\t\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003e\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\tThe Agilent 1260 Infinity I HPLC G4212B DAD Detector is in excellent condition and will be fully tested to perform at factory\nspecifications before being shipped.\n\t\t\u003cbr\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e\u003c\/span\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G4212B DAD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nDeuterium Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G4212B Diode Array Detector Specifications\u003c\/h2\u003e\n\t\u003ctable border=\"1\" style=\"background-color: rgb(255, 255, 255); font-size: 16px;\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cspan id=\"selection-marker-1\"\u003e\u003c\/span\u003eDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 640 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 3 × 10^-6 AU at 230 nm\/4 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.5 × 10^-3 AU\/hr at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\t\u003cbr\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.0 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t2 - 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tFixed 4 nm slit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~ 0.5 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSignal Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectra Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t80 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cells\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tMax-Light Cartridge Cell (10 mm, V [σ], 1.0ul), 60 bar (870 psi) pressure maximum\n\t\t\t\t\u003cbr\u003e\u003cbr\u003eMax-Light Cartridge Cell (60 mm, V [σ], 4.0ul), 60 bar (870 psi) pressure maximum\u003cbr\u003e\u003cbr\u003eMax-Light Cartridge Test Cell\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tControl and Data Evaluation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAgilent ChemStation for LC\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAnalog Outputs\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tRecorder\/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tController-area network (CAN), GPIB, \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eRS-232C, APG Remote: ready, start, \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003estop and shut-down signals, LAN\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSafety and Maintenance\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tExtensive diagnostics, error detection, and display (through control module \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eand ChemStation), leak detection, safe \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eleak handling, leak output signal for \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eshutdown of pumping system. Low \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003evoltages in major maintenance areas.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument \n\t\t\t\t\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eusage in terms of lamp burn time with \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003euser-settable limits and feedback \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emessages. Electronic records of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003emaintenance and errors. Verification of \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003ewavelength accuracy with built-in \u003c\/span\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eholmium oxide filter.\u003c\/span\u003e\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHousing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAll materials recyclable\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003co:p\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/o:p\u003e\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G4212B_Manual_-_Marshall_Scientific.pdf?v=1779985273\" target=\"_blank\"\u003eAgilent 1260 Infinity HPLC G4212B DAD Detector Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G4212B_-_Marshall_Scientific.pdf?v=1779985277\" target=\"blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/marshdoc_6a60f823-6a0b-4621-bdd8-8e71c369a0fb.png?v=1779984276\"\u003eClick Here to View the Technical Specs for the Agilent 1260 Infinity G4212B DAD Detector\u003cbr\u003e\u003c\/a\u003e\u003c\/b\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2266.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474505732186,"sku":"AG-DAD1260","price":10995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260-2.jpg?v=1761207561"},{"product_id":"agilent-1260-infinity-ii-hplc-g7115a-dad-detector","title":"Agilent 1260 Infinity II HPLC G7115A DAD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7115A DAD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e1024-element photodiode array\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eData Rate\u003c\/b\u003e\u003cbr\u003e120 Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eEngineered for peak optical performance and GLP compliance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEasy maintenance with front access for quick component replacement\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e120 Hz data acquisition rate suitable for ultra-fast LC applications\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLong-life deuterium and tungsten lamps covering 190 to 950 nm wavelength range\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRFID tags on flow cells and UV lamps for enhanced traceability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSimultaneous detection of up to eight wavelengths without loss of sensitivity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit adjustable from 1 to 16 nm for optimal sensitivity and resolution\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in holmium oxide filter for fast wavelength accuracy checks\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTemperature control features for stable baselines under varying conditions\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDiagnostic tools for monitoring temperature and lamp voltage\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260II_5d3c2ec7-104b-4542-a59a-ef31c841fc4b.jpg?v=1779985392\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7115A DAD Detector is engineered to provide top-notch optical performance, ensuring compliance with Good Laboratory Practices (GLP) and offering ease of maintenance. It features a rapid 120 Hz data acquisition rate that is ideal for ultra-fast liquid chromatography applications. Equipped with long-life deuterium and tungsten lamps, the detector achieves high intensity and low detection limits across a wide wavelength range of 190 to 950 nm. Unique RFID tags on all flow cells and UV lamps ensure accurate traceability of component data.\n\t\u003cbr\u003e\u003cbr\u003e\n\tUsers benefit from the detector’s ability to maintain sensitivity while simultaneously analyzing up to eight wavelengths. The programmable slit, adjustable from 1 to 16 nm, allows fine-tuning of sensitivity, linearity, and spectral resolution. Maintenance is streamlined through easily accessible front components for quick replacement. It also incorporates a built-in holmium oxide filter for rapid wavelength accuracy verification, and temperature controls for enhanced baseline stability. Additional features include diagnostic signals for monitoring temperature and lamp voltage, thus bolstering the detector's reliability in fast-paced analytical environments.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7115A DAD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nTungsten and Deuterium Lamps\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7115A DAD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Signals\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t120 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM) Single and Multi-Wavelength\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.7 x 10\n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU, at 254 and 750 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 x 10\n\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/h at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 - 400 nm, programmable in 1 nm steps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t~ 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5 x 15.6 x 17 in. (14 x 39.6 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26.5 lb. (12 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 110VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7115A_DAD_Detector_-_Marshall_Scientific.pdf?v=1779985396\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7115A_DAD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985400\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2765.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474507403354,"sku":"AG-DAD1260II","price":14295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260II-2.jpg?v=1761207590"},{"product_id":"agilent-1260-infinity-ii-hplc-g7165a-mwd-detector","title":"Agilent 1260 Infinity II HPLC G7165A MWD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7165A MWD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e 190 to 950 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e1024-element photodiode array\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eData Rate\u003c\/b\u003e\u003cbr\u003e120 Hz\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDesigned for highest optical performance, GLP compliance, and easy maintenance\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRFID tags on all flow cells and UV lamps for enhanced traceability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in holmium oxide filter enables fast wavelength accuracy verification\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in temperature controls improve baseline stability\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigher sensitivity and selectivity with simultaneous detection of up to eight wavelengths\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow detection limits achieved through low noise electronics and patented flow cell design\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eProgrammable slit from 1 to 16 nm allows for rapid optimization of sensitivity and linearity\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eNine analytical and preparative flow cells for extensive application flexibility\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExtensive diagnostics, error detection, and display capabilities with Instant Pilot controller and Lab Advisor software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260II_5d3c2ec7-104b-4542-a59a-ef31c841fc4b.jpg?v=1779985392\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7165A Multiple Wavelength Detector (MWD) combines high optical performance, GLP compliance, and simplified maintenance to meet the needs of fast-paced laboratory environments. This detector boasts a 120 Hz data acquisition rate, making it ideal for fast LC applications, and features long-life deuterium lamps that provide intense light across a wide wavelength range of 190 to 950 nm. Enhanced traceability is ensured through RFID tags on all flow cells and UV lamps.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe device's built-in holmium oxide filter allows for rapid verification of wavelength accuracy, while integrated temperature controls enhance baseline stability. Diagnostic signals are available for monitoring temperature and lamp voltage, ensuring consistent operation. The detector's high sensitivity and selectivity are achieved through simultaneous detection of up to eight compound-specific wavelengths, and its advanced design includes low noise front-end electronics and a patented flow cell that significantly reduces short-term noise.\n\t\u003cbr\u003e\u003cbr\u003e\n\tWith its programmable slit ranging from 1 to 16 nm, users can easily optimize sensitivity and linearity to suit various applications. The MWD offers a wide linear range for accurate quantification of primary compounds, by-products, and impurities. It also features nine analytical and preparative flow cells for maximum flexibility, complemented by extensive diagnostics, error detection, and display capabilities via the Instant Pilot controller and Agilent Lab Advisor software, making the Agilent 1260 Infinity II MWD an exceptional choice for sophisticated analytical tasks.\n\t\u003cbr\u003e\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7165A MWD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nTungsten and Deuterium Lamps\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7165A MWD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1024-element photodiode array\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium and tungsten lamps\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Signals\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t8\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tData Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t120 Hz (both spectra and signals)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 to 950 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tShort Term Noise (ASTM)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.7 x 10 \n\t\t\t\t\u003csup\u003e-5\u003c\/sup\u003e AU at 254 nm and 750 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.9 x 10 \n\t\t\t\u003csup\u003e-3\u003c\/sup\u003e AU\/h at 254 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinear Absorbance Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 2 AU (5%) at 265 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Bunching\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1, 2, 4, 8, 16 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDiode Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 13 µL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp bandwidth, auto balance,\nwavelength range, threshold, spectra storage mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5 x 15.6 x 17 in. (14 x 39.6 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26.5 lb. (12 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 110VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7165A_MWD_Detector_-_Marshall_Scientific.pdf?v=1779985471\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7165A_MWD_Detector_User_Manual_-_Marshall_Scientific.pdf?v=1779985478\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2908.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474509664346,"sku":"AG-MWD1260","price":10202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-MWD1260-2.jpg?v=1761207916"},{"product_id":"agilent-1260-infinity-i-hplc-g1311b-quat-pump","title":"Agilent 1260 Infinity I HPLC G1311B Quat Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1311B Quat Pump\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Accuracy\u003c\/b\u003e\u003cbr\u003e ± 1% or 10 µl\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSetable Flow Range\u003c\/b\u003e\u003cbr\u003e0.001 – 10 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Range \u003c\/b\u003e\u003cbr\u003e0.2 – 10.0 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eFeatures a robust two-channel, dual-plunger in-series design for comprehensive solvent delivery functions.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCapable of generating gradients through low-pressure mixing from four individual solvent channels.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAchieves virtually pulse-free and stable solvent flow with variable stroke volume.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePump assembly can generate pressures up to 600 bar, efficiently metering solvent and delivering it to the high-pressure side.\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated 4-channel vacuum degasser built into the quaternary pump to ensure efficient degassing of solvents.\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/1260_G1311B.jpg?v=1779985101\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\nThe Agilent 1260 Infinity HPLC G1311B Quaternary Pump is based on a two-channel, dual-plunger in-series design which comprises all essential functions that a solvent delivery system has to fulfill, generating gradients by low pressure mixing from four individual solvent channels. The G1311B ensures virtually pulse-free and stable solvent flow via the variable stroke volume. Metering of solvent and delivery to the high-pressure side are performed by one pump assembly, which can generate pressure up to 600 bar. Degassing of solvents is accomplished with an integrated 4-channel vacuum degasser built into the quaternary pump. Solvent compositions are generated on the low-pressure side by a high speed proportioning valve.\n\t\u003c\/p\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\t\t\u003cbr\u003eAll of our equipment is fully tested to perform at factory\nspecifications before being shipped.\n\t\u003c\/p\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity HPLC G1311B Quat Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Leak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1311B Quat Pump Specifications\u003c\/h2\u003e\n\t\u003co:p\u003e\u003c\/o:p\u003e\n\t\u003cp\u003e\n\t\u003c\/p\u003e\n\t\u003ctable class=\"MsoTableGrid\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-width: 1pt; border-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tSetable Flow Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top-width: 1pt; border-right-width: 1pt; border-bottom-width: 1pt; border-top-color: windowtext; border-right-color: windowtext; border-bottom-color: windowtext; border-left: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0.001 – 10 mL\/min, in 0.001 mL\/min increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tFlow Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0.2 – 10.0 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tFlow Precision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t≤ 0.07% RSD, or ≤ 0.02 min SD whatever is greater, based on retention\n  time at constant room temperature\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tFlow Accuracy\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t± 1% or 10 µl\/min whatever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tPressure Operating Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0 – 60 MPa (0 – 600 bar, 0 – 8,700 psi) up to 5 mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0 – 20 MPa (0 – 200 bar, 0 – 2,950 psi) up to 10\n  mL\/min\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tPressure Pulsation\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t\u0026lt; 2% amplitude or \u0026lt; 3 bar at 1 mL\/min isopropanol, at all pressure \u0026gt; 1 MPa (10 bar, 145 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tRecommended pH Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t1.0 – 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which\n  attack stainless steel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tGradient Formation\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary\n  high-speed proportioning valve\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\tDelay Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t600 - 900µl, dependent on back pressure\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tComposition Range\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t0 – 95% or 5 – 100%, user selectable\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tComposition Precision\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t\u0026lt; 0.2% RSD or \u0026lt; 0.04 min SD\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cspan id=\"selection-marker-1\"\u003e\u003c\/span\u003eIntegrated Degassing Unit\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\tNumber of channels: 4\n\t\t\t\u003cbr\u003e\u003cbr\u003eInternal volume per channel: 1.5 mL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd width=\"193\" valign=\"top\" style=\"width: 144.9pt; border-right-width: 1pt; border-bottom-width: 1pt; border-left-width: 1pt; border-right-color: windowtext; border-bottom-color: windowtext; border-left-color: windowtext; border-top: none; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\tElectrical Requirements\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd width=\"445\" valign=\"top\" style=\"width: 333.9pt; border-top: none; border-left: none; border-bottom-width: 1pt; border-bottom-color: windowtext; border-right-width: 1pt; border-right-color: windowtext; padding: 0in 5.4pt;\"\u003e\n\t\t\t\u003cp class=\"MsoNormal\" style=\"margin-bottom:0in;margin-bottom:.0001pt;line-height: normal\"\u003e\n\t\t\t\t100 - 240V, 50\/60 Hz, 180 VA\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G1311B_-_Marshall_Scientific.pdf?v=1779985105\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_G1311B_Manual_-_Marshall_Scientific.pdf?v=1779985109\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent1200SeriesG1311A_Spec.pdf?v=1779984644\" target=\"blank\"\u003e\n\t\u003c\/a\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2264.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474510090330,"sku":"AG-Quat1260","price":8510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-Quat1260-2.jpg?v=1761207994"},{"product_id":"agilent-1260-infinity-i-hplc-g1314f-vwd-detector","title":"Agilent 1260 Infinity I HPLC G1314F VWD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1314F VWD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eWavelength Range (DAD)\u003c\/b\u003e\u003cbr\u003e190 - 600 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eNoise\u003c\/b\u003e\u003cbr\u003e\u0026lt; ± 0.25 x 10-5 AU, at 230 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDrift\u003c\/b\u003e\u003cbr\u003e1 x 10-4 AU\/hr, at 230 nm\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDouble-beam photometer with deuterium lamp for reliable detection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eTime-programmable control of wavelength, polarity, peak width, and lamp settings\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003e80 Hz data acquisition rate for improved resolution in fast LC analyses\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eWide linear range for simultaneous quantification of primary compounds, by-products, and impurities\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eStop-flow wavelength scanning for quick wavelength optimization\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRFID-enabled flow cells and lamps for enhanced traceability and easy tracking\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic wavelength verification with built-in holmium oxide filter\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExtensive diagnostics and error detection via Instant Pilot controller and Lab Advisor software\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eEarly maintenance feedback (EMF) with lamp usage tracking and alerts\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFront access to lamps and flow cells for simplified maintenance and reduced downtime\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/G1314F_6325d748-9c1a-44e0-aa88-ff16e8769306.jpg?v=1779985136\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity I HPLC G1314F Variable Wavelength Detector (VWD) offers high sensitivity and robust performance for HPLC applications. With time-programmable wavelength switching and a double-beam design, it delivers enhanced selectivity and low detection limits. Hardware improvements ensure minimal noise (\u0026lt; ±2.5 µAU) and baseline drift (\u0026lt;1 x 10⁻⁴ AU\/h), while advanced optics and electronics provide consistent signal quality and reliable detection across a wide range of methods. An 80 Hz data acquisition rate supports fast, accurate results. Additional features include a wide linear range for quantifying primary compounds and impurities, RFID-enabled flow cells and lamps, and built-in wavelength verification using a holmium oxide filter. Front access to components, diagnostics, and early maintenance feedback (EMF) make service fast and efficient, maximizing uptime and reliability.\n\t\u003cbr\u003e\n\t\u003c!--1--\u003e\n\t\u003c!--1--\u003e\n\t\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1314F VWD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nDeuterium Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1314F VWD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.25 x 10-5 AU, at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 x 10-4 AU\/hr, at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt;2.5 AU upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5nm typical over whole wavelength range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp on\/off\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStop-flow wavelength scan\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5 x 13.5 x 17 in. (14 x 34.5 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t24.3 lb. (11 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 80VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1314F_VWD_Detector_-_Marshall_Scientific.pdf?v=1779985140\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1314F_VWD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985144\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2905.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474510614618,"sku":"AG-VWD1260I","price":8050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-VWD1260I-2.jpg?v=1761208103"},{"product_id":"agilent-1260-infinity-ii-hplc-g7114a-vwd-detector","title":"Agilent 1260 Infinity II HPLC G7114A VWD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7114A VWD Detector\u003c\/h1\u003e\n\t\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7114A Variable Wavelength Detector (VWD) delivers exceptional sensitivity and speed, making it an industry leader in its class. With time-programmable wavelength switching and dual-wavelength mode, this detector enhances sensitivity, selectivity, and data acquisition. Advanced hardware improvements ensure low detector noise (\u0026lt; ±2.5 AU) and minimal baseline drift (\u0026lt;1 x 10^-4 AU\/h), enabling precise quantification of trace-level components. Featuring electronic temperature control (ETC) for maximum baseline stability under varying environmental conditions and a 120 Hz data acquisition rate for fast analysis, the detector supports high productivity and reliable quantification. Additional features include a wide linear range for analyzing primary compounds and impurities, RFID-enabled flow cells and lamps for enhanced traceability, and automated wavelength verification via a built-in holmium oxide filter. Maintenance is streamlined with front access to lamps and flow cells, extensive diagnostics, and early maintenance feedback (EMF) for tracking lamp usage, ensuring maximum uptime and efficiency.\n\t\u003cbr\u003e\n\t\u003c!--1--\u003e\n\t\u003cbr\u003e\n\tAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7114A VWD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nDeuterium Lamp\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Guide\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7114A VWD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\tDetection Type\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDouble-beam photometer\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDeuterium lamp\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t190 - 600 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNoise\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.25 x 10^-5 AU, at 230 nm (single wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\t\u003cp\u003e\n\t\t\t\t\u0026lt; ± 0.80 x 10^-5 AU, at 230 nm and 254 nm (dual wavelength detection)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDrift\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 x 10^-4 AU\/h at 230 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLinearity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026gt; 2.5 AU upper limit\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; ± 0.1 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSlit Width\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t6.5nm typical over whole wavelength range\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTime Programmable\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength, polarity, peak width, lamp on\/off\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Cell\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 14 µl volume, 10 mm cell path length and 40 bar (588 psi) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectral Tools\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStop-flow wavelength scan\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t5.5 x 15.6 x 17 in. (14 x 39.6 x 43.6 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t24.3 lb. (11 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 80VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7114A_VWD_Detector_-_Marshall_Scientific.pdf?v=1779985383\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7114A_VWD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985388\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/2807.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":42474510712922,"sku":"AG-VWD1260II","price":9745.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-VWD1260II-2.jpg?v=1761208129"},{"product_id":"agilent-1260-infinity-ii-hplc-g7121b-fld-detector","title":"Agilent 1260 Infinity II HPLC G7121B FLD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7121B FLD Detector\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e Multi-signal fluorescence detector w\/ rapid on-line scanning capabilities and spectral data analysis\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eLight Source\u003c\/b\u003e\u003cbr\u003e\t\nXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eStandard Flow Cell \u003c\/b\u003e\u003cbr\u003e8 uL volume and 20 bar (2 MPa) pressure maximum\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eMulti-signal capability with rapid on-line scanning and advanced spectral data analysis\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports both single and dual wavelength operation for flexible method development\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eWide excitation and emission wavelength range from 200 nm to 1200 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFast spectrum acquisition with scan speeds as low as 28 ms per datapoint\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eHigh data rate performance up to 148 Hz for efficient data collection\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePrecise wavelength repeatability of ± 0.2 nm with accuracy of ± 3 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated spectral storage with adjustable step size from 1 to 20 nm\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eComprehensive safety features including leak detection and automated system shutdown signals\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eFlexible communication interfaces including CAN, USB, and ERI signal integration\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLDS.jpg?v=1779985423\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003cp class=\"MsoNormal\"\u003e\n\tThe Agilent 1260 Infinity II HPLC G7121B FLD Detector delivers high-sensitivity fluorescence detection with multi-signal capability and rapid on-line scanning for advanced spectral analysis. Designed for flexible operation, this detector enables both single and dual wavelength measurements while supporting excitation and emission spectrum acquisition within a single system. Its wide wavelength range (200–1200 nm) and fast scan speeds allow for efficient data collection and detailed spectral characterization, making it well-suited for demanding HPLC workflows.\n\t\t\u003cbr\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7121B FLD Detector also features high data rates, precise wavelength repeatability and in-line excitation reference measurement provide comprehensive analysis. Engineered with reliability and compliance in mind, the G7121B also includes built-in safety features such as leak detection, safe leak handling, and automated shutdown signals. GLP-focused functionality provides early maintenance feedback, electronic tracking of instrument usage, and wavelength accuracy verification. Combined with broad communication options and robust construction, the G7121B ensures dependable performance and ease of use in modern analytical laboratories.\n\t\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\n\t\t\u003cbr\u003e\u003cbr\u003e\n\t\u003c\/p\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7121B FLD Detector includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n 8ul Flow Cell\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lab Advisor Calibration Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Lan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Operator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\n Full 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7121B FLD Detector Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDetection Type\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tMulti-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPerformance Specifications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSingle Wavelength Operation: RAMAN (H2O) \u0026gt; 500 (noise reference measured at signal), Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell\n\t\t\t\u003cbr\u003e RAMAN (H2O) \u0026gt; 3000 (noise reference measured at dark value), Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell \u003cbr\u003eDual Wavelength Operation: RAMAN (H2O) \u0026gt; 300 Ex 350 nm, Em 397 nm and Ex 350 nm, Em 450 nm, standard flow cell\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tLight Source\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tXenon Flash Lamp, normal mode 20 W, economy mode 5 W, lifetime 4000 h\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPulse Frequency\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t296 Hz for single signal mode \n\t\t\t\u003cbr\u003e74 Hz for economy mode\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Data Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t148 Hz\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation Monochromator\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tRange: settable 200 nm - 1200 nm and zero-order\n\t\t\t\u003cbr\u003eBandwidth: 20 nm (fixed)\u003cbr\u003eMonochromator: concave holographic grating, F\/1.6, blaze: 300 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tEmission Monochromator\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tRange: settable 200 nm - 1200 nm and zero-order\n\t\t\t\u003cbr\u003eBandwidth: 20 nm (fixed)\u003cbr\u003eMonochromator: concave holographic grating, F\/1.6, blaze: 400 nm\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tReference System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tIn-line excitation measurement\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tTimetable Programing\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSpectrum Acquisition\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tExcitation or Emission spectra\n\t\t\t\u003cbr\u003eScan speed: 28 ms per datapoint (e.g. 0.6 s\/spectrum 200 – 400 nm, 10 nm step)\u003cbr\u003eStep Size: 1 – 20 nm\u003cbr\u003eSpectra storage: All\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWavelength characteristic\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tRepeatability: +\/- 0.2 nm\n\t\t\t\u003cbr\u003eAccuracy: +\/- 3 nm setting\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow cells\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tStandard: 8 uL volume and 20 bar (2 MPa) pressure maximum\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t15.6 x 17 x 5.5 in. (39.6 x 43.6 x 14 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t26.2 lbs. (11.9 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 70VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7121B_FLD_Detector_-_Marshall_Scientific.pdf?v=1779985427\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7121B_FLD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985431\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3145.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428347871322,"sku":"AG-1260FLDS","price":12995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FLDS-2T.jpg?v=1779979978"},{"product_id":"agilent-1260-infinity-ii-hplc-g7104c-flexible-pump","title":"Agilent 1260 Infinity II HPLC G7104C Flexible Pump","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7104C Flexible Pump\n\t\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eSettable Flow Range\u003c\/b\u003e\u003cbr\u003e 0.001 to 5 ml\/min, in 0.001 ml\/min increments\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Precision\u003c\/b\u003e\u003cbr\u003e\t≤ 0.07 % RSD or 0.01 min SD, whichever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eFlow Accuracy \u003c\/b\u003e\u003cbr\u003e± 1 % or ± 10 uL\/min, whichever is greater\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eDual-piston pump with servo-controlled variable stroke design for smooth flow and active damping\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow pressure pulsation for stable and consistent solvent delivery\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAccurate solvent composition control with low delay volume for reproducible gradients\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic compressibility compensation for improved performance across solvent types\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eIntegrated 4-channel degassing unit for reliable solvent preparation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic purge valve enabling simplified maintenance and system operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eComprehensive communication interfaces including CAN, LAN, RS232C, and remote signals\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAdvanced safety features including leak detection and automated shutdown signals\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eGLP-focused functionality with early maintenance feedback and electronic record tracking\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eExtensive diagnostics and error detection supported through Agilent control software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FP.jpg?v=1779985344\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7104C Flexible Pump delivers precise and reliable solvent delivery with a dual-piston, servo-controlled design engineered for smooth flow and active damping. Supporting flow rates from 0.001 to 5 mL\/min with fine resolution, this pump ensures consistent performance across a wide range of HPLC applications. Its high-pressure capability up to 800 bar, combined with low pulsation, enables stable operation even under demanding analytical conditions.\n\t\u003cbr\u003e\u003cbr\u003e\n\tThe G7104C Flexible Pump features low-pressure quaternary gradient formation with a high-speed proportioning valve, allowing accurate mixing of up to four solvents. With precise composition control and low delay volume, the system provides reproducible gradients. Additional functionality such as automatic compressibility compensation, integrated degassing, and an automatic purge valve enhances ease of use while maintaining consistent solvent delivery.  \u003cbr\u003e\u003cbr\u003e\n\tDesigned for flexibility and system integration, the Agilent 1260 Infinity II HPLC G7104C Flexible Pump is equipped with extensive communication interfaces including CAN, LAN, and RS232C. Built-in safety features such as leak detection, safe leak handling, and automated shutdown signals help protect both the instrument and workflow. GLP-focused capabilities provide continuous tracking of seal wear and usage, along with electronic maintenance records, ensuring reliable operation and simplified compliance in modern laboratory environments. \u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7104C Flexible Pump includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLeak and Pressure Diagnostic Report\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7104C Flexible Pump\n Specifications\n\t\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tHydraulic System\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tDual pistons in series pump with proprietary servo-controlled variable stroke design and smooth motion control for active damping\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable Flow Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.001 to 5 ml\/min, in 0.001 ml\/min increments\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t≤ 0.07 % RSD or 0.01 min SD, whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tFlow Accuracy\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t± 1 % or ± 10 uL\/min, whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Operating Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tUp to 80 MPa (800 bar, 11603 psi) up to 5 mL\/min\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure Pulsation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 1 % amplitude or \u0026lt; 0.5 MPa (5 bar), whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCompressibility Compensation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tAutomatic (when using \"solvent types\" in method)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tRecommended pH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1.0 to 12.5, solvents with pH \u0026lt; 2.3 should not contain acids which attack stainless steel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGradient Formation\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLow pressure quaternary mixing\/gradient capability using proprietary high-speed proportioning valve\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDelay Volume\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t≤ 350 uL (default configuration)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tComposition Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tSettable range: 0 to 100 %\n\t\t\t\u003cbr\u003eRecommended range: 1 to 99 %\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tComposition Precision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.15 % RSD or 0.02 min SD, whichever is greater\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tIntegrated Degassing Unit\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of channels: 4 Internal volume per channel: 1.5 ml\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t15.6 x 17.2 x 7.1 in. (39.6 x 43.6 x 18 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t35.5 lbs. (16.1 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 120VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7104C_Flexible_Pumps_-_Marshall_Scientific.pdf?v=1779985347\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7104C_Flexible_Pump_Manual_-_Marshall_Scientific.pdf?v=1779985352\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3146.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428349444186,"sku":"AG-1260FP","price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260FP-2T.jpg?v=1779980085"},{"product_id":"agilent-1260-infinity-i-hplc-g1322a-degasser","title":"Agilent 1260 Infinity I HPLC G1322A Degasser","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity I HPLC G1322A Degasser\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eMaximum Flow Rate\u003c\/b\u003e\u003cbr\u003e 10 ml\/min per channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eNumber of Channels\u003c\/b\u003e\u003cbr\u003e\t4\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInternal Volume per Channel\u003c\/b\u003e\u003cbr\u003eTypically 12 mL per channel\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eMembrane-based degassing design removes dissolved gases from mobile phases\u003c\/li\u003e\n\t\t\t\t\u003cli\u003ePressure sensor continuously monitors vacuum conditions during operation\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eAutomatic switching between operating modes to maintain effective degassing\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eBuilt-in diagnostics detect abnormal vacuum conditions and trigger protective responses\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eStatus indicators provide clear visual feedback on operating and error states\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eError output supports system monitoring and fault reporting\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eDesigned to support stable baselines and reproducible chromatographic performance\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IDG.jpg?v=1779985189\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity I HPLC G1322A Degasser is designed to effectively remove dissolved gases from mobile phases, helping ensure stable pump performance and consistent chromatographic results. The system uses a four-channel vacuum container with tubular membrane technology, allowing solvents to pass through gas-permeable membranes where dissolved gases are efficiently removed under controlled vacuum conditions. Vacuum generation and regulation are automatically managed by an internal pump and pressure sensor, which maintain the appropriate vacuum level during operation. The degasser continuously monitors system pressure and adjusts pump activity as needed to keep the vacuum within defined operating limits. Multiple operating modes support reliable degassing under varying conditions, while integrated diagnostics detect abnormal vacuum levels and initiate protective responses in the event of a fault.\n\t\u003cbr\u003e\u003cbr\u003e\n\tBuilt for dependable day-to-day LC operation, the G1322A provides consistent solvent degassing with minimal user intervention. Its controlled vacuum management, membrane-based degassing design, and integrated monitoring functions make it a reliable component for maintaining baseline stability and reproducible performance in Agilent 1260 Infinity LC systems.\n\t\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \u003cbr\u003e\n\t\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1322A Degasser includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity I HPLC G1322A Degasser Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaximum Flow Rate\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t10 ml\/min per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tNumber of Channels\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInternal Volume per Channel\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically 12 mL per channel\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tMaterials in Contact with Solvent\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t PTFE, PEEK\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tpH Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t1 to 14\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (H x W x D)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t13.5 x 17 x 3.1 in. (34.5 x 43.5 x 8 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t16 lb. (7 kg.)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 5W\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\t\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\t\u003cdiv class=\"downloads-section\"\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1322A_Degasser_-_Marshall_Scientific.pdf?v=1779985193\" target=\"blank\"\u003e\n\t\t\tTechnical Specification Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1322A_Degasser_Manual_-_Marshall_Scientific.pdf?v=1779985197\" target=\"blank\"\u003e\n\t\t\tOperator's Manual Download\n\t\t\t\u003c\/a\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"formalquote2\"\u003e\n\t\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3090.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428350591066,"sku":"AG-1260IDG","price":2995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260IDG-2T.jpg?v=1779980153"},{"product_id":"agilent-1260-infinity-ii-hplc-g7129a-vialsampler","title":"Agilent 1260 Infinity II HPLC G7129A Vialsampler","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\t\u003ch1\u003eAgilent 1260 Infinity II HPLC G7129A Vialsampler\n\t\u003c\/h1\u003e\n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-section\"\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003eInjection Range\u003c\/b\u003e\u003cbr\u003e0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePrecision\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 uL to 100 uL\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"inner-highlight-div\"\u003e\n\t\t\t\u003cp class=\"inner-highlight\"\u003e\n\t\t\t\t\u003cb\u003ePressure Range\u003c\/b\u003e\u003cbr\u003e\n\t\t\t\t0 – 60 MPa (0 – 600 bar, 0 – 8702 psi)\n\t\t\t\u003c\/p\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"highlights-divider\"\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"features-section\"\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\t\t\t\u003cul\u003e\n\t\t\t\t\u003cli\u003eHigh-capacity autosampler designed for routine LC workflows\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eSupports reliable and reproducible sample introduction\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eDual vial drawer design accommodates large sample sets\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eRobotic gripper arm ensures precise and flexible vial handling\u003c\/li\u003e\n\t\t\t\t\u003cli\u003e\u003cspan style=\"background-color: initial; letter-spacing: 0px;\"\u003eNeedle wash reduces carryover between injections\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eOverlapped injection capability improves sample throughput\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCustomizable injection programs support advanced sample handling steps\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eLow internal volume minimizes contribution to system dispersion\u003c\/li\u003e\n\t\t\t\t\u003cli\u003eCompatible with Agilent InfinityLab LC systems and standard control software\u003c\/li\u003e\n\t\t\t\u003c\/ul\u003e\n\t\t\u003c\/div\u003e\n\t\t\u003cdiv class=\"features-side\"\u003e\n\t\t\t\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260VS.jpg?v=1779985444\"\u003e\n\t\t\u003c\/div\u003e\n\t\u003c\/div\u003e\n\tThe Agilent 1260 Infinity II HPLC G7129A Vialsampler is a high-capacity autosampler designed for reliable, routine liquid chromatography in pharmaceutical quality control, environmental analysis, and food testing applications. Built for ease of use and consistent operation, the G7129A supports precise and reproducible sample handling. The vialsampler accommodates up to 132 sample vials using dual vial drawers and employs a robotic gripper arm driven by stepper motors to ensure accurate and flexible vial transport. Its automated needle wash function rinses the outside of the needle to help minimize carryover between injections. Overlapped injection capability and customizable injection programs support efficient sample handling and improved throughput.\n\t\u003cbr\u003e\u003cbr\u003e\n\tDesigned for integration within Agilent InfinityLab LC systems, the G7129A features a low internal volume that minimizes contribution to overall system dispersion, helping preserve chromatographic performance and reproducibility. For temperature-sensitive applications, optional thermostatted modules support precise temperature control to maintain sample integrity throughout analysis.\u003cbr\u003e\u003cbr\u003eAll of our equipment is fully tested to perform at factory specifications before being shipped.   \n\t\u003cbr\u003e\u003cbr\u003e\n\t\u003cdiv class=\"included-box\"\u003e\n\t\t\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity II HPLC G7129A Vialsampler includes:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFront Cover\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nTwo 66 x 2 mL Vial Trays\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nPower Cord\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nLab Advisor Documentation\u003c\/li\u003e\n\t\t\t\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\u003c\/div\u003e\n\t\u003cbr\u003e\n\t\u003ch2\u003eAgilent 1260 Infinity II HPLC G7129A Vialsampler Specifications\u003c\/h2\u003e\n\t\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPressure\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0 – 60 MPa (0 – 600 bar, 0 – 8702 psi)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tGLP Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tEarly maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits and feedback messages. Electronic records of maintenance and errors\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCommunications\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tController Area Network (CAN), Local Area Network (LAN) \n\t\t\t\u003cbr\u003eERI: ready, start, stop and shut-down signals\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSafety Features\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tLeak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.1 – 100 uL in 0.1 uL increments with 100 uL up to 60 MPa\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tPrecision\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t\u0026lt; 0.25 % RSD of peak areas from 5 uL to 100 uL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tCarryover\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically \u0026lt; 0.004% with needle wash\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Viscosity Range\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t0.2 to 5 cP\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tSample Capacity\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t132 x 2 ml vials\n\t\t\t\u003cbr\u003e100 x 2 mL vials\u003cbr\u003e36 x 6 mL vials\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tInjection Cycle Time\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\tTypically 18 s for draw speed 200 uL\/min and injections volume of 1 uL\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tAmbient Operating Temperature\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t4 to 55°C\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tDimensions (W x D x H)\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t15.6 x 18.4 x 12.8 in. (39.6 x 46.8 x 32 cm)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tWeight\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t41.9 lb. (19 kg)\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003ctr\u003e\n\t\t\u003ctd\u003e\n\t\t\tElectrical Requirements\n\t\t\u003c\/td\u003e\n\t\t\u003ctd\u003e\n\t\t\t100-240V, 50\/60Hz, 350VA\n\t\t\u003c\/td\u003e\n\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7129A_Vialsampler_-_Marshall_Scientific.pdf?v=1779985448\" target=\"blank\"\u003e\n\t\tTechnical Specification Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\t\u003cdiv class=\"pdf-button\"\u003e\n\t\t\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_II_HPLC_G7129A_Vialsampler_Manual_-_Marshall_Scientific.pdf?v=1779985455\" target=\"blank\"\u003e\n\t\tOperator's Manual Download\n\t\t\u003c\/a\u003e\n\t\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\n\t\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3091.htm\" target=\"blank\"\u003eRequest a Formal Quote\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428356685914,"sku":"AG-1260VS","price":13125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-1260VS-2T.jpg?v=1779980237"},{"product_id":"agilent-1260-infinity-i-hplc-g1315c-dad-detector","title":"Agilent 1260 Infinity I HPLC G1315C DAD Detector","description":"\u003cdiv class=\"productdescriptiontables\"\u003e\n\u003ch1\u003eAgilent 1260 Infinity I HPLC G1315C DAD Detector\u003c\/h1\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"highlights-section\"\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eWavelength Range\u003c\/b\u003e\u003cbr\u003e190 to 950 nm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eDetection Type\u003c\/b\u003e\u003cbr\u003e1024-element photodiode array\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"inner-highlight-div\"\u003e\n\u003cp class=\"inner-highlight\"\u003e\u003cb\u003eData Rate\u003c\/b\u003e\u003cbr\u003eUp to 80Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"features-section\"\u003e\n\u003cdiv class=\"features-side\"\u003e\n\u003cspan class=\"features-header\"\u003eFeatures\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eHigh optical performance designed for reliable, low-noise chromatographic detection\u003c\/li\u003e\n\u003cli\u003eProgrammable slit width allows optimization of sensitivity, linearity, and spectral resolution\u003c\/li\u003e\n\u003cli\u003eLong-life deuterium and tungsten lamps for stable intensity and low detection limits\u003c\/li\u003e\n\u003cli\u003eElectronic temperature control stabilizes the complete optical unit\u003c\/li\u003e\n\u003cli\u003eEarly maintenance feedback supports proactive service and usage monitoring\u003c\/li\u003e\n\u003cli\u003eExtensive diagnostics with error detection and leak handling for safe operation\u003c\/li\u003e\n\u003cli\u003eFront-accessible lamps and flow cell enable fast, straightforward maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-side\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260I.jpg?v=1779985148\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\nThe Agilent 1260 Infinity I HPLC G1315C DAD Detector is engineered for high optical performance and dependable operation in both routine and advanced LC applications. Built around a 1024-element photodiode array, the detector delivers accurate spectral data across a broad wavelength range from 190 to 950 nm, supporting both UV and visible compound analysis. Long-life deuterium and tungsten lamps provide high light intensity and low detection limits, while maintaining stable performance over extended operating periods. \u003cbr\u003e\u003cbr\u003eDesigned to support fast and flexible chromatography, the G1315C offers data acquisition rates up to 80 Hz. A programmable slit width from 1 to 16 nm allows users to optimize sensitivity, linearity, and spectral resolution for specific methods. Electronic temperature control of the optical unit further stabilizes detector performance and minimizes baseline drift under changing laboratory conditions. \u003cbr\u003e\u003cbr\u003eFor traceability and simplified maintenance, all flow cells and lamps are equipped with RFID tags that record identification and usage data to support GLP documentation. Built-in diagnostics, data recovery capability, and early maintenance feedback help protect results and reduce the risk of data loss. Easy front access to lamps and the flow cell enables fast replacement during routine service, minimizing downtime. Together, these features make the Agilent 1260 Infinity I HPLC G1315C DAD Detector a reliable, feature-rich solution for high-confidence chromatographic detection. \u003cbr\u003e\u003cbr\u003eAll of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped. \u003cbr\u003e\u003cbr\u003e\n\u003cdiv class=\"included-box\"\u003e\n\u003cspan class=\"included-header\"\u003eINCLUDED:\u003c\/span\u003e\u003cbr\u003eThe Agilent 1260 Infinity I HPLC G1315C DAD Detector includes:\n\u003cul\u003e\n\u003cli\u003e\nFirmware Version 07.02 (Can be changed upon request)\u003c\/li\u003e\n\u003cli\u003e\nFlow Cell\u003c\/li\u003e\n\u003cli\u003e\nCompactFlash Card\u003c\/li\u003e\n\u003cli\u003e\nTungsten and Deuterium Lamps\u003c\/li\u003e\n\u003cli\u003e\nLab Advisor Calibration Report\u003c\/li\u003e\n\u003cli\u003e\nLan Cable \/ Power Cord\u003c\/li\u003e\n\u003cli\u003e\nOperator's Manual\u003c\/li\u003e\n\u003cli\u003e\nFull 180 Day Parts and Labor Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eAgilent 1260 Infinity I HPLC G1315C DAD Detector Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Type\u003c\/td\u003e\n\u003ctd\u003e1024-element photodiode array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eDeuterium and tungsten lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 80Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 to 950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Term Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.7 x 10 \u003csup\u003e-5\u003c\/sup\u003e AU at 254 and 750 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.9 x 10 \u003csup\u003e-3\u003c\/sup\u003e AU\/h at 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2 AU (5%) at 265 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Bunching\u003c\/td\u003e\n\u003ctd\u003eProgrammable, 1 to 400 nm in steps of 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Width\u003c\/td\u003e\n\u003ctd\u003e1, 2, 4, 8, 16 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Width\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Cell\u003c\/td\u003e\n\u003ctd\u003e13 ul volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Tools\u003c\/td\u003e\n\u003ctd\u003eData analysis software for spectra evaluation, including spectral libraries and peak purity functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e13.5 x 17 x 5.5 in. (34.5 x 43.5 x 14 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e25.4 lb. (11.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e100-240V, 50\/60Hz, 160VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan class=\"downloads-header\"\u003eDownloads\u003c\/span\u003e\n\u003cdiv class=\"downloads-section\"\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1315C_DAD_Detector_-_Marshall_Scientific.pdf?v=1779985152\"\u003e Technical Specification Download \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"pdf-button\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/Agilent_1260_Infinity_I_HPLC_G1315C_DAD_Detector_Manual_-_Marshall_Scientific.pdf?v=1779985158\"\u003e Operator's Manual Download \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"formalquote2\"\u003e\u003ca class=\"formalquote2link\" href=\"\/formal_quote_a\/3086.htm\"\u003eRequest a Formal Quote\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.downloads-section {\n        justify-content: center;\n    }\n\u003c\/style\u003e","brand":"Marshall scientific","offers":[{"title":"Default Title","offer_id":43428372119642,"sku":"AG-DAD1260I","price":10695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/5853\/1418\/files\/AG-DAD1260I-2T.jpg?v=1780427631"}],"url":"https:\/\/marshallscientific.com\/collections\/agilent-1260-infinity-hplc-systems-and-components.oembed","provider":"Marshall Scientific","version":"1.0","type":"link"}