VistaLab Ovation Quick-Set 20ul, 200ul, 1000ul Electronic Pipette Set
The VistaLab Ovation Quick-Set 20ul, 200ul, 1000ul Electronic Pipette Set is a variable volume air displacement pipette set for aspirating and dispensing volumes between 2
l and 1000l, with precision, comfort, and ease. The large LCD display and motor-driven volume adjustments offer precise transfer, with storage for up to five "one-button" presets. The Ovation QS Electronic Pipettes also feature a unique ergonomic design, allowing the user to keep their hand relaxed and comfortable throughout continuous use.
All of our equipment will be fully tested to perform at factory specifications before being shipped.
The VistaLab Ovation Quick-Set 20ul, 200ul, 1000ul Electronic Pipette Set includes:
- > Gravimetric Analysis Calibration Reports
- > Full 180 Day Parts and Labor Warranty
VistaLab Ovation Quick-Set 20ul, 200ul, 1000ul Electronic Pipette Set Specifications
Volume
|
Increment
|
Accuracy
|
Precision
|
2l
10l
20l
20l
100l
200l
100l
500l
1000l
|
0.02l
0.2l
1.0l
|
7.0%
1.5%
1.0%
2.5%
0.8%
0.8%
3.0%
0.8%
0.8%
|
2.00%
0.50%
0.30%
1.00%
0.25%
0.15%
0.60%
0.20%
0.15%
|
Click Here to View the Technical Specs for the VistaLab Ovation Electronic Pipette Set
- Thoroughly inspect and clean all internal components, identifying and replacing any damaged or compromised parts
- Replace all essential wear components, including O-rings, seals, tip holders, and friction rings, to ensure optimal performance
- Examine plunger and seal holders for signs of rust, wear, or damage, replacing components as necessary for operational integrity
- Verify that no leakage is present by aspirating a sample and observing for any fluid loss
- Confirm that the Mettler Toledo AB104-S balance is precisely calibrated for accurate pipette calibration measurements
- Perform a detailed gravimetric calibration, recording all findings in the comprehensive calibration report
- Ensure that all external parts are meticulously cleaned and free from any foreign contaminants
- Test the tip ejector for smooth and reliable operation, addressing any misalignment or obstruction
- Affix a dated calibration sticker to indicate recent and verified calibration
- Conduct a detailed cosmetic inspection, confirming that all surfaces and finishes meet established quality and aesthetic standards
Technician Inspection and Recertification Checklist: Pipettes
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Thoroughly inspect and clean all internal components; replace damaged parts
|
Completed
|
|
Replace essential wear components like O-rings, seals, and friction rings
|
Completed
|
|
Examine plunger and seal holders for wear or damage; replace if needed
|
Completed
|
|
Verify no leakage is present by aspirating sample and checking for fluid loss
|
Completed
|
|
Confirm Mettler Toledo AB104-S balance calibration for accurate measurements
|
Completed
|
|
Perform detailed gravimetric calibration and record findings in report
|
Completed
|
|
Clean all external parts meticulously to remove any contaminants
|
Completed
|
|
Test tip ejector for smooth, reliable operation; correct misalignments
|
Completed
|
|
Affix dated calibration sticker to indicate verified calibration
|
Completed
|
|
Conduct cosmetic inspection to ensure quality of surfaces and finishes
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|