Popular Alternative Choice
Thermo Scientific Napco 8000 CO2 Water Jacketed Incubator
- Pinpoint CO2 & temp control for advanced cell cultures.
- 100% HEPA filtration for Class 100 air quality.
- Temp range: Ambient +5°C to 55°C; CO2 range: 0-20%.
- Water Jacketed for stable temperature conditions.
Go to Product Details
Fully Recertified!
VWR 2310 Water Jacketed CO2 Incubator
The VWR 2310 Water Jacketed CO2 Incubator is micro-processor
based, allowing highly accurate control of both CO2 and temperature. The 2310s
compact design is ideal for small volume applications and preventative of cross
contamination. With its water jacketed design, this incubator guarantees
excellent temperature control and uniformity. A thermal conductivity cell
measures CO2 level, and the 2310 incubator has an independent over-temperature
protection feature. Audio and visual alarms indicate high or low temperature,
high or low CO2 level, and low water level in the water jacket. The VWR 2310 is
easily calibrated with keypad control and features LED digital display.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The VWR 2310 Water Jacketed CO2 Incubator includes:
- > Calibration
- > 2 Shelves
- > Drain Tray
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
VWR 2310 Water Jacketed CO2 Incubator Specifications
Exterior Dimensions (W x H x D)
|
21 x 25 x 21 in
|
Interior Dimensions (W x H x D)
|
15 x 15 x 15 in
|
Volume
|
56.6 L (2 cu. ft.)
|
Temperature Range
|
5C above ambient to 50C
|
Temperature Uniformity
|
+/- 0.1C at 37C
|
CO2 Range
|
0 to 20%
|
CO2 Uniformity
|
0.25%
|
Electrical
|
120V, 60Hz, 6amps
|
VWR 2310 Water Jacketed CO2 Incubator Manual Click Here to View all the Technical Specs for the VWR 2310
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, CO₂, and H₂O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate CO₂ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and CO₂ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dim, flickering, or dead pixels; replace for readability
|
Completed
|
|
Examine external regulators for damage or malfunction; replace compromised parts
|
Completed
|
|
Inspect temperature, CO₂, and H₂O sensors for correct function and accuracy
|
Completed
|
|
Inspect internal wiring for frays, tears, or breakages; replace compromised wires
|
Completed
|
|
Verify software settings align with components and calibration specs; adjust if needed
|
Completed
|
|
Clean fan and remove dust/obstructions; replace if performance is substandard
|
Completed
|
|
Examine wheels and leveling mounts for structural integrity and balance
|
Completed
|
|
Inspect door gaskets and latches for wear or damage; replace to maintain seal
|
Completed
|
|
Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy
|
Completed
|
|
Calibrate CO₂ level to 5% with Fyrite test kit for atmospheric precision
|
Completed
|
|
Monitor temperature and CO₂ stability over 24-hour period to verify consistency
|
Completed
|
|
Conduct cosmetic inspection to confirm quality of external surfaces and components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|