VWR 1575R Refrigerated Incubator Shaker
Shaking Speed 30 to 400 RPM
Temperature Range Ambient -20C to 70C
- Microprocessor-controlled temperature adjustment within 0.1°C precision.
- High-performance brushless DC motor with speeds from 30 to 400 rpm.
- Smooth rotation on a 12, 19, or 25mm orbit.
- Noncontact, low watt density nichrome heating element for maximum service life.
- Accommodates temperatures from 20°C below ambient to 70°C with ±0.5°C uniformity.
- Ideal for genetic research, cell aeration, bacterial aeration, metabolism studies, and tissue culture studies.
The VWR 1575R is a benchtop refrigerated incubator shaker
with microprocessor control, allowing for precise temperature adjustment within
0.1°C. The VWR 1575R's high-performance brushless DC motor develops speeds of 30
to 400 rpm with smooth rotation on a 12, 19, or 25mm orbit. The noncontact, low watt density nichrome
heating element provides maximum service life. Expect temperatures from 20°C below ambient to 70°C with ±0.5°C uniformity.
The VWR 1575R is ideal for genetic research, cell aeration,
bacterial aeration, metabolism studies, and tissue culture studies.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The VWR 1575R Refrigerated Incubator Shaker includes:
- > NIST Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
VWR 1575R Refrigerated Incubator Shaker Specifications
Temperature Range
|
Ambient -20° to 70°C
|
Temperature Uniformity
|
±0.5°C
|
Temperature Sensitivity
|
0.1°C
|
Speed
|
30 to 400 rpm
|
Volume
|
167 L (5.8 cu. ft.)
|
Orbit Diameter
|
12, 19, or 25 mm
|
Max Sample Weight
|
10 kg (22 lbs)
|
Refrigerant
|
R134A
|
Shelf Dimensions
|
47 x 47 cm (18.5 x 18.5 in)
|
Interior Dimensions
|
48 x 51 x 66 cm (19 x 19.25 x 23.5 in)
|
Exterior Dimensions
|
58 x 69 x 105 cm (23.5 x 28.5 x 40.5 in)
|
Electrical
|
110-120 V, 50/60 Hz
|
VWR 1575R Manual
Click Here to View all the Technical Specs for the VWR 1575R
- Examine the chamber glass for cracks or chips, replacing it as needed to maintain structural integrity.
- Inspect door seals for signs of wear or damage, replacing them to ensure a tight seal.
- Check the display for brightness and clarity, replacing any dim or dead pixels to maintain optimal visibility.
- Test all buttons to confirm full functionality and consistent responsiveness.
- Replace all platform assembly bearings to ensure smooth and reliable motion.
- Inspect the drive belt for wear, replacing it if torn or cracked to maintain performance.
- Examine all wiring for frays, tears, or breakages, addressing any issues for electrical safety.
- Verify each PCB test point, replacing any malfunctioning components to ensure system reliability.
- Check drive belt tension to confirm correct alignment and function.
- Confirm the compressor’s operation, cleaning condenser filter and fins for efficient cooling.
- Calibrate internal temperature accuracy using an NIST-traceable temperature probe.
- Measure and calibrate platform RPMs with an NIST-traceable tachometer to ensure precision.
- Conduct a final cosmetic inspection to verify all surfaces meet appearance standards.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task |
Completed? |
Remarks? |
Examine chamber glass for cracks or chips, replace as needed | Completed | |
Inspect door seals for wear, replace to ensure tight seal | Completed | |
Check display brightness, replace dim or dead pixels | Completed | |
Test all buttons for full functionality and responsiveness | Completed | |
Replace platform assembly bearings for reliable motion | Completed | |
Inspect drive belt for wear, replace if torn or cracked | Completed | |
Examine wiring for frays or breakages, repair as needed | Completed | |
Verify PCB test points, replace faulty components | Completed | |
Check drive belt tension for proper alignment | Completed | |
Confirm compressor functionality, clean filter and fins | Completed | |
Calibrate internal temperature with NIST probe | Completed | |
Calibrate platform RPM with NIST-traceable tachometer | Completed | |
Conduct cosmetic inspection for appearance standards | Completed | |
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|