Popular Alternative Choice
Tuttnauer 3870EAP Digital Autoclave, 230V
- Designed to autoclave wrapped, unwrapped, glass and tools
- Temperature selection from 105°C to 137°C
- Allows closed door drying
- 2 Year Manufacturer's Warranty
Go to Product Details
Brand New and No Lead Time!
Tuttnauer 3870EAP Autoclave
Sterilization Temperature Range 105°C to 137°C
Chamber Dimensions 15 x 27 in. (38.1 x 68.6 cm)
- Designed to autoclave wrapped, unwrapped, glass and tools.
- Not suitable for liquids
- Sterilization time up to 99 minutes
- Temperature selection from 105°C to 137°C
- Includes trays
- In-line particle filter to protect valves
- Electronic pressure and temperature sensors
- Low Water Alarm - sounds when reservoir needs to be refilled
- Standby Heating - keeps chamber warm for quicker cycles
- Built-In Printer - Provides a printed summary at the end of each cycle, documenting temperature, elapsed sterilization and drying time, selected cycle number, real time and date, as well as any errors or interruptions that may occur during the cycle
- Chamber Volume – 85L
- Power – 230V, 1 Phase (60Hz) NEMA 6-15
The Tuttnauer 3870EA Autoclave is a large automatic table top autoclave that is perfect for many environments include multi-doctor practices, clinics, or surgery centers. The 15"x 30" chamber accommodates longer instruments or a large number of small instruments. Features closed door active drying system to maintain sterility and ensure efficient drying, long life electro polished chamber and door, brighter, easier to read panel, program parameters that can be customized and stored, and the optional internal printer that prints documents such as date, time, temperature, and pressure. The 3870EA is also equipped with an air compressor that, during the drying stage, draws air through a HEPA filter (0.2m). It pushes that air through the heated chamber to remove moisture and facilitate the drying operation.
All of our equipment is fully tested to perform at factory specifications before being shipped.
The Tuttnauer 3870EAP Digital Autoclave includes:
- > 2 Trays
- > Printer
- > Operator's Guide
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Tuttnauer 3870EAP Autoclave Specifications
Chamber
Volume
|
85 L
|
Chamber Size
(Diameter x Depth)
|
15 x 27 in
|
Temperature
Range
|
105C to
137C
|
Standard
Cassettes Capacity
|
15 full
|
Number of
Trays
|
2
|
Tray
Dimensions (H x W x D)
|
675 x 25 x 286
mm
|
Overall
Dimensions (H x W x D)
|
660 x 525 x 875
mm
|
Electrical
Requirements
|
230V,
50/60Hz, 13A, 3000W
|
Tuttnauer 3870EA Manual
Click Here to View all the Technical Specs for the 3870EA
- Verify power supply output to ensure precise voltage delivery as per equipment specifications
- Check full display functionality, replacing any dead or dim pixels for optimal clarity
- Confirm unit is level to maintain stability and accurate operational performance
- Inspect door seal integrity, replacing if any wear or damage compromises airtight performance
- Examine and clean both external and internal filters to ensure unobstructed airflow and system efficiency
- Execute comprehensive cycle testing to validate consistent operation
- Verify printer functionality (if applicable) to ensure precise print outputs without error
- Assess internal plumbing system for any leaks or pressure inconsistencies
- Inspect all electrical connections and wiring for secure attachment and optimal conductivity
- Verify functionality of internal switches to ensure reliable engagement and operational control
- Inspect and clean the water reservoir to maintain purity and prevent contamination
- Confirm accuracy of pressure readings, recalibrating if deviations are identified
- Perform final test cycles, ensuring zero errors for validated operational readiness
Technician Inspection and Recertification Checklist: Autoclaves
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify power supply output voltages
|
Completed
|
|
Check display functionality and replace dead/dim pixels
|
Completed
|
|
Confirm unit leveling for stability
|
Completed
|
|
Inspect and replace damaged door seal
|
Completed
|
|
Clean external and internal filters for airflow efficiency
|
Completed
|
|
Conduct comprehensive cycle testing
|
Completed
|
|
Confirm printer functionality (if applicable)
|
Completed
|
|
Assess plumbing for leaks or pressure issues
|
Completed
|
|
Inspect electrical connections for secure and optimal conductivity
|
Completed
|
|
Verify internal switch functionality
|
Completed
|
|
Inspect and clean water reservoir
|
Completed
|
|
Confirm pressure reading accuracy and recalibrate if needed
|
Completed
|
|
Perform final test cycles with zero errors
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|