Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge
Temperature Range
-9 to +40C
- Easy-to-read display and control panel for effortless operation of centrifuge functions.
- Reaches a maximum force of 24,400 x g, suitable for intensive separation.
- Offers a range from -9 to +40°C, making it versatile for various laboratory requirements.
- Constructed with 8 mm steel for durability and safety.
- Lid with viewing window allows for sample observation without interruption.
- Secure lid lock with safety check ensures the centrifuge operates when the lid is locked.
- Automatic rotor identification streamlines workflow.
- Switches between speed and RCF display effortlessly, even during operation.
The Thermo Sorvall Legend RT+ Refrigerated Benchtop Centrifuge offers remarkable user-friendly capabilities, including an easy-to-read digital display and easy user control of all centrifuge capabilities. With a low height of only 12.4 inches, the Sorvall Legend RT+ makes rotor loading and unloading effortless. This refrigerated benchtop centrifuge has a max g-force of about 24,400 x g and features a timer that can be set at points as low as 1 min all the way to time periods lasting up to 9 hours and 59 minutes. With a temperature range of -9 to +40C, the Sorvall Legend RT+ is the perfect centrifuge for any laboratory situation. This rotor reaches a maximum speed of 4,150 RPM.All of our equipment is fully tested to perform at factory specifications before being shipped. Please confirm this rotor meets your application needs and request a different rotor, if necessary. Available rotors can be found in our Rotor Compatibility Guide.
The Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge includes:
- > 75006434 Swing Bucket Rotor and Buckets
- > 1 Set of 15ml Adapters
- > 1 Set of 50ml Adapters
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Thermo Sorvall Legend RT Plus Refrigerated Benchtop Centrifuge Specifications
Maximum Speed |
15,000 RPM |
Minimum Speed |
300 RPM |
Maximum RCF |
24,400 x g |
Maximum Capacity |
4 x 750ml |
Temperature Range |
-9°C to 40°C |
Timer |
Up to 9 hours 59 minutes, 59 seconds, with continuous run (hold) |
Display |
Full color touch screen interface |
Program Storage |
4 user programs |
Noise Level |
< 55 dB(A) |
Dimensions (H x W x D) |
14.3 x 28.7 x 26.2 in. (36.2 x 73.3 x 66.6 cm) |
Weight |
288 lb. (131 kg) |
Electrical Requirements |
115V, 60Hz, 12A |
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly
- Confirm the power supply output voltages match specified requirements for stable distribution to all internal components
- Measure and verify voltages at PCB test points to ensure accurate power delivery and circuit integrity
- Confirm rotor compatibility with the centrifuge model and check that rotor detection systems recognize the rotor type
- Inspect the exterior for any cosmetic or structural damage that could affect performance or safety
- Check the door mechanism alignment to ensure secure and smooth opening and closing
- Inspect and replace the gas strut with an OEM part to maintain proper door support and safety
- Examine the rotor chamber bowl for dents or damage and replace as needed to ensure safe operation
- Replace and confirm full functionality of all lid lock switches to maintain secure closure
- Inspect and lubricate the door lock mechanism, applying grease to the lid lock rail for smooth operation
- Test compressor functionality (if applicable) to ensure proper operation and consistent temperature control
- Conduct an 8-12 hour cycle test to validate consistent performance over prolonged use
- Confirm rotor motor stability, check for unusual noise, and assess mechanical integrity during operation
- Inspect the condensation drain and clear any clogs to prevent moisture buildup in the rotor chamber
- Verify RPM accuracy using an NIST-traceable tachometer and perform calibration as necessary
- Check the centrifuge error log to ensure zero recorded issues, confirming system reliability
Technician Inspection and Recertification Checklist: Centrifuges
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task |
Completed? |
Remarks? |
Confirm power supply output voltages match specified requirements |
Completed |
|
Measure and verify voltages at PCB test points for accuracy |
Completed |
|
Confirm rotor compatibility and detection for proper identification |
Completed |
|
Inspect exterior for cosmetic or structural damage |
Completed |
|
Check door mechanism alignment for secure opening and closing |
Completed |
|
Inspect and replace gas strut with OEM part as needed |
Completed |
|
Examine rotor chamber for dents or damage and replace if necessary |
Completed |
|
Replace and confirm functionality of all lid lock switches |
Completed |
|
Lubricate door lock mechanism and lid lock rail for smooth operation |
Completed |
|
Test compressor (if applicable) for proper operation and cooling |
Completed |
|
Run 8-12 hour cycle test to ensure consistent performance |
Completed |
|
Check rotor motor for stability, noise, and integrity |
Completed |
|
Inspect and clear condensation drain to prevent buildup |
Completed |
|
Verify RPM accuracy with NIST traceable tachometer and calibrate |
Completed |
|
Check centrifuge error log for zero recorded issues |
Completed |
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|