|
|
|
|
Popular Alternative Choice
VWR Gravity Convection Incubator, Cat. #: 89511-422
- Unique airflow for delicate sample conditions.
- Temp range: Ambient +5°C to 75°C, uniformity ± 0.6°C.
- 194L volume with internal glass door for viewing.
- PID control, easy cleaning, and diverse applications.
Go to Product Details
Fully Recertified!
Thermo Scientific Heratherm IMH60-S Incubator
The Thermo Scientific Heratherm IMH60-S Incubator is an advanced
protocol security incubator designed for outstanding sample safety with
exceptional temperature performance via dual convection. This incubator is equipped with high-precision work space temperature control, adjustable in steps of one-tenth of a degree from 5°C above ambient up to 105°C.
The Thermo Scientific Heratherm IMH60-S Incubator features a unique 140°C decontamination routine, comparable to sterilization,
which eliminates the need for separate autoclaving of interior fittings. An advanced digital timer allows for the unit to turn on or off at specified times, with
weekly, real time, and hourly settings. An access port is also featured, which allows for the use of stirrers, shakers, additional sensors, etc. inside of the incubator chamber. Automatic over-and-under temperature alarm ensures
sample protection, alongside lockable door and door alarm. A stainless steel
interior also allows for easy cleaning and resists corrosion.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Thermo Scientific Heratherm IMH60-S Incubator includes:
- > 2 Shelves
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Thermo Scientific Heratherm IMH60-S Incubator Specifications
Temperature Range
|
Ambient +5°C to 105°C
|
Temperature Uniformity
|
± 0.6°C
|
Temperature Stability
|
± 0.1°C
|
Timer
|
Weekly / Real Time / Hourly
|
Volume
|
66 L (2.33 cu. ft.)
|
Chamber Material
|
Stainless Steel
|
Internal Dimensions (D x W x H)
|
14.5 x 13.9 x 20 in (36.8 x 35.4 x 50.8 cm)
|
External Dimensions (L x W x H)
|
22.2 x 20.9 x 28.3 in (56.5 x 53 x 72 cm)
|
Electrical Requirements
|
120V, 60Hz, 11.6A, 1390W
|
Thermo Scientific Heratherm IMH60-S Incubator Manual
Click Here to View the Technical Specs for the Thermo Scientific Heratherm IMH60-S
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, CO₂, and H₂O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate CO₂ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and CO₂ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dim, flickering, or dead pixels; replace for readability
|
Completed
|
|
Examine external regulators for damage or malfunction; replace compromised parts
|
Completed
|
|
Inspect temperature, CO₂, and H₂O sensors for correct function and accuracy
|
Completed
|
|
Inspect internal wiring for frays, tears, or breakages; replace compromised wires
|
Completed
|
|
Verify software settings align with components and calibration specs; adjust if needed
|
Completed
|
|
Clean fan and remove dust/obstructions; replace if performance is substandard
|
Completed
|
|
Examine wheels and leveling mounts for structural integrity and balance
|
Completed
|
|
Inspect door gaskets and latches for wear or damage; replace to maintain seal
|
Completed
|
|
Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy
|
Completed
|
|
Calibrate CO₂ level to 5% with Fyrite test kit for atmospheric precision
|
Completed
|
|
Monitor temperature and CO₂ stability over 24-hour period to verify consistency
|
Completed
|
|
Conduct cosmetic inspection to confirm quality of external surfaces and components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|