|
|
|
|
Polyscience LS51MX1A110C LS5 Benchtop Chiller
- 1290W Cooling Capacity
- 13.2 l/min Flow Rate
- Brand New
- 2 Year Manufacturer's Warranty
Go to Product Details
Thermo Neslab Merlin M33 Circulating Chiller, 230V
The Thermo Neslab Merlin M33 Circulating Chiller, 230V is
compact and portable, while also providing excellent cooling capacity and
reliability. This chiller features a unique easy-to-view reservoir and user
adjustable low and high temperature safety with alarm. The Merlin M33 has an
integrated internal pressure reducer and flow controller, which eliminate
concern for premature wear and make for easy fluid changes. Translucent
reservoir enables quick viewing of fluid level, and removable front panel
condenser vent allows for easy access for routine cleaning and preventative
maintenance.
Recommended for biotech, pharmaceutical, laser, laboratory,
analytical instrumentation, printing, semiconductor, industrial, and medical
use.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
Included with the Thermo Neslab Merlin M33 Circulating Chiller, 230V:
Includes:
> Operator's Guide > Power Cord > Full 90
Day Parts and Labor Warranty
Thermo Neslab Merlin M33 Circulating Chiller, 230V Specifications
Temperature Range
|
+5 to +35C
|
Cooling Capacity
|
1142w, 3897 BTU/hour
|
Capacity
|
0.5 gallons, (1.8 liters)
|
Length x Width x Height
|
20.9 x 12.6 x 23.5 in
|
Temperature Stability
|
0.1C
|
Voltage
|
230V
|
Display
|
Digital
|
Refrigerant
|
R134A
|
Pump Type
|
Turbine
|
Max Flow Rate
|
6.75L/min
|
- Cooling capacity test is performed at 20C to confirm chiller functionality
- Flow rate is tested to verify pump is meeting manufacturer specifications
- Chiller is temperature cycled numerous times to ensure longevity of instrument
- Low temperature test is performed to ensure chiller is functioning within temperature range
- Pump is Inspected for Faults and Signs of Disrepair
- Motor is Inspected for Shorts and Corroded Wiring
- Plumbing is Inspected for Leaks and Corrosion
- Filters are Cleaned and Replaced if Needed
- Tank is Inspected for Leaks and Cleaned
- Internal Circuitry is Inspected for Faulty/Shorted Components and Replaced Accordingly
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Pump is Lubricated as Needed
Thermo Neslab Merlin M33 Chiller Manual
Click Here to View all the Technical Specs for the M33
Polyscience LS51MX1A110C LS5 Benchtop Chiller
- 1290W Cooling Capacity
- 13.2 l/min Flow Rate
- Brand New
- 2 Year Manufacturer's Warranty
Go to Product Details
- Inspect display for dimming or dead pixels and replace as necessary to maintain clear visual feedback
- Verify functionality of all buttons and input devices, ensuring reliable and responsive control
- Check that all external hosing connections are secure and properly installed to prevent leakage
- Test unit flow rate on a closed-loop system to confirm consistent fluid dynamics
- Examine all external surfaces for leaks, confirming a sealed and contained system
- Inspect internal components for any signs of leaks to ensure system integrity
- Verify power supply output for accurate voltage delivery per operational specifications
- Inspect all internal wiring, checking for any frays, tears, or compromised insulation
- Replace internal filters to maintain optimal fluid purity and system performance
- Confirm that the fan operates at proper speeds to provide effective cooling
- Verify compressor functionality for consistent performance and cooling efficiency
- Test cooling capacity, confirming it meets performance specifications at 20°C
- Measure water pump output to confirm correct PSI for stable fluid flow
- Determine the lowest achievable temperature, verifying against manufacturer standards
- Ensure cosmetic condition meets standards with no damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Recirculating Chiller
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dimming or dead pixels, replace if necessary
|
Completed
|
|
Verify functionality of all buttons and input devices
|
Completed
|
|
Ensure external hosing connections are secure
|
Completed
|
|
Test flow rate on closed-loop system
|
Completed
|
|
Inspect for external leaks
|
Completed
|
|
Inspect for internal leaks
|
Completed
|
|
Verify power supply output voltage
|
Completed
|
|
Inspect internal wiring for frays or tears
|
Completed
|
|
Replace internal filters
|
Completed
|
|
Confirm fan functionality
|
Completed
|
|
Verify compressor functionality
|
Completed
|
|
Test cooling capacity at 20°C
|
Completed
|
|
Confirm water pump PSI output
|
Completed
|
|
Determine lowest achievable temperature
|
Completed
|
|
Ensure cosmetic condition meets standards
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|