Recertification Protocol
Technical Specification Sheet
 

Thermo Fisher ThermoChill II Recirculating Chiller


The Thermo Fisher ThermoChill II Recirculating Chiller features innovative design, such as minimized plumbing connections and an integrated full-flow fluid strainer to maximize reliability. The ThermoChill II chiller reaches temperatures from -10C to +30C with a stability of 0.1C.

All of our equipment is fully tested to perform at factory specifications before being shipped.


INCLUDED:
The Thermo Fisher ThermoChill II Recirculating Chiller includes:
  • > > MD-30 Pump
  • > > PM & Calibration Report
  • > > Operator's Manual
  • > > Power Cord
  • > > Full 180 Day Parts and Labor Warranty

Thermo Fisher ThermoChill II Recirculating Chiller Specifications

Temperature Range

-10C to +30C

Temperature Stability

0.1C

Pumping Capacity MD-30 Pump

2.0 gpm @ 6.0 psid (7.6 lpm @ 0.4 bar)

2.0 gpm @ 4.2 psid (7.6 lpm @ 0.3 bar)

Cooling Capacity

1000W

Reservoir Volume

2.5 Gallons / 9.5 Liters

Dimensions (H x W x D)

62 x 36.1 x 60 cm (24.4 x 14.2 x 23.6 in)

Weight

90 lbs (40.8 kg)


Tests Performed on the Thermo Fisher ThermoChill II Recirculating Chiller

  • Cooling capacity test is performed at 20C to confirm chiller functionality
  • Flow rate is tested to verify pump is meeting manufacturer specifications
  • Chiller is temperature cycled numerous times to ensure longevity of instrument
  • Low temperature test is performed to ensure chiller is functioning within temperature range

Preventative Maintenance Performed on the Thermo Fisher ThermoChill II Recirculating Chiller

  • Pump is Inspected for Faults and Signs of Disrepair
  • Motor is Inspected for Shorts and Corroded Wiring
  • Plumbing is Inspected for Leaks and Corrosion
  • Filters are Cleaned and Replaced if Needed
  • Tank is Inspected for Leaks and Cleaned
  • Internal Circuitry is Inspected for Faulty/Shorted Components and Replaced Accordingly
  • Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
  • Pump is Lubricated as Needed


ThermoChill II Chiller Manual
Click Here to View the Technical Specs for the ThermoChill II


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Circulating Chillers
Brand > Thermo Scientific
Brand > Fisher Scientific
Chiller Low Temp > -10°C
Chiller Cooling Capacity Range > 501 to 1000 Watts
Chiller Flow Rate Range > 7 to 13 LPM
Chiller Low Temp
Chiller Cooling Capacity Range
Chiller Flow Rate Range
Brand