Talboys Standard Analog 4 Block Heater, Cat. # 949516
The Talboys Standard Analog 4 Block Heater, Cat. # 949516 is designed for applications that require repeatable results and superior temperature stability. This multi-purpose unit is ideal for applications such as incubation and activation of cultures, enzyme reactions, immunoassays, melting/boiling points, and a wide variety of other laboratory procedures. The Talboys Standard Analog 4 Block Heater accepts interchangeable modular heat blocks, accommodating various tube sizes from 0.2ml to 50ml.
The Talboys Standard Analog 4 Block Heater, Cat. # 949516 has the ability to provide efficient heating due to close tube-to-block contact for maximum heat retention. This heater features an overall temperature range of Ambient +5C to 150C, with analog dials with markings from 1 to 10 for low and high temperature adjustments. The low range knob adjusts from Ambient to 100C, and the high range knob adjusts from 75C to 150C. This unit also features microprocessor control, offering a temperature stability as low as 2.0C, as well as a temperature uniformity as low as 0.1C.
All of our equipment is fully tested to perform at factory specifications before being shipped.
Talboys Standard Analog 4 Block Heater, Cat. # 949516 includes:
- > 4 x Heat Blocks as Pictured
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Talboys Standard Analog 4 Block Heater, Cat. # 949516 Specifications
Temperature Range
|
Ambient +5 to 150C
|
Temperature Stability
|
2.0C
|
Temperature Uniformity
|
0.1C
|
Heat-Up Time to 100C
|
70 minutes
|
Weight
|
8.5 lbs. (3.9 kg.)
|
Dimensions (L x W x H)
|
16.9 x 8 x 3.5 in. (42.9 x 20.3 x 8.9 cm)
|
Electrical Requirements
|
120V, 50/60Hz, 2.6A, 310W
|
- Verify the number and correct sizes of heat blocks to ensure compliance with system specifications
- Test functionality of all displays, knobs, and switches, ensuring reliable control and accurate readings
- Inspect all internal wiring for any signs of damage, including frays or compromised insulation
- Clean internal insulation and chamber to maintain optimal thermal efficiency and system hygiene
- Check machine feet and confirm the unit sits properly balanced for stable operation
- Use an independent temperature probe to confirm heating accuracy within the specified temperature range
- Validate temperature uniformity across heat blocks for consistent thermal distribution
- Inspect line cord for any signs of wear, cuts, or damage affecting safety or performance
- Ensure cosmetic condition meets quality standards, free of damage that could impact operation or aesthetics
Technician Inspection and Recertification Checklist: Dry Bath Heater
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify the number and sizes of heat blocks
|
Completed
|
|
Test functionality of displays, knobs, and switches
|
Completed
|
|
Inspect internal wiring for damage
|
Completed
|
|
Clean internal insulation and chamber
|
Completed
|
|
Check machine feet for proper balance
|
Completed
|
|
Confirm heat within range using an independent probe
|
Completed
|
|
Validate temperature uniformity across heat blocks
|
Completed
|
|
Inspect line cord for damage
|
Completed
|
|
Ensure cosmetic condition is acceptable
|
Completed
|
|