The Talboys Professional 1000IC-3 Digital Incubating/Cooling Orbital Shaker offers shaking speeds from 100 to 1,200 RPM on a 3 mm orbit with temperatures from 10C below ambient to 65C. This unit is microplate ready or can accommodate modular blocks with a 5 inch tall interior capacity. Ideal for analses that require a stable, controlled temperature.
The Talboys Professional 1000IC-3 Digital Incubating/Cooling Orbital Shaker, Cat. # 980187 includes:
- > Platform
- > NIST Calibration and Preventative Maintenance Report
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Talboys Professional 1000IC-3 Digital Incubating/Cooling Orbital Shaker Specifications
Speed Range
|
100 to 1,200 RPM
|
Temperature Range
|
Ambient -10 to 65C
|
Temperature Uniformity
|
0.5C
|
Timer
|
1 sec to 160 hours
|
Orbit
|
3 mm (0.12 in)
|
Maximum Capacity
|
2 microplates or 2 modular blocks
|
Overall Dimensions (L x H x W)
|
17.9 x 11 x 10.5 in
|
Electrical Requirements
|
230V, 50/60Hz, 1A, 200W
|
Talboys Professional 1000IC-3 Digital Incubating/Cooling Orbital Shaker Manual
Click Here to View the Technical Specs for the Talboys 1000IC-3
- Validate that the power supply and PCB deliver stable, correct voltage outputs across all necessary connections, ensuring reliable operation
- Thoroughly inspect the display for any dim, flickering, or dead pixels; replace affected elements to maintain full readability and operational clarity
- Test the full range of button functionality, confirming responsive, accurate input recognition across all settings
- Conduct a detailed inspection of bearings and bearing housing, identifying any worn or damaged bearings, and replace as needed to prevent operational disruption
- Examine the drive belt for signs of cracking, fraying, or material breakdown; replace as required to ensure sustained performance
- Measure and adjust motor drive belt tension to optimal specifications, securing reliable and efficient power transmission
- Verify accuracy of the onboard timer, confirming proper functionality and replacing if it deviates from expected performance
- Calibrate shaker rotation speed with a NIST-traceable tachometer, validating precision within specified operational limits
- Run the shaker continuously for an 8-12 hour testing period, closely observing the shaking platform for smooth, consistent motion, while monitoring for any error indicators such as knocking, skipping, or unusual vibrations
- Perform a comprehensive cosmetic inspection to confirm the device’s exterior meets aesthetic and quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Shakers
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Validate stable, correct voltage outputs from power supply and PCB
|
Completed
|
|
Inspect display for dim, flickering, or dead pixels; replace as needed
|
Completed
|
|
Test button functionality for responsiveness and accuracy across all settings
|
Completed
|
|
Inspect bearings and housing for wear; replace as needed to prevent disruption
|
Completed
|
|
Examine drive belt for cracking, fraying, or material breakdown; replace as required
|
Completed
|
|
Measure and adjust motor drive belt tension to optimal specifications
|
Completed
|
|
Verify onboard timer accuracy; replace if it deviates from expected performance
|
Completed
|
|
Calibrate shaker rotation speed using a NIST-traceable tachometer
|
Completed
|
|
Run 8-12 hour continuous test; observe platform for smooth, consistent motion
|
Completed
|
|
Perform comprehensive cosmetic inspection for quality standards compliance
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|