Sanyo MCO-20AIC CO2 Incubator
Temperature Range Ambient +5°C to 50°C
Internal Dimensions 24.4 x 20.6 x 26.2 in.
- Equipped with a UV contamination control system for maintaining a sterile environment.
- Infrared sensor ensures precise CO2 level control, vital for sensitive cultures.
- Microprocessor PID Control provides reliable and consistent environmental conditions.
- Outer door with a magnetic seal and a door heater to eliminate moisture.
- Top and rear ducts are removable for easy maintenance.
- Water Level Sensor monitors water levels in the humidifying pan, ensuring optimal humidity.
- Disinfectable Fan made from polypropylene resin and suitable for autoclave disinfection.
The Sanyo MCO-20AIC CO2 Incubator is designed to deliver precise humidity/CO2 and temperature control for cell cultures in medical, pharmaceutical, and medical research and clinical labs. This incubator has an interior capacity of 195 L with temperatures up to 50°C and up to 20% CO2 control. Features Safe Cell UV contamination control system, infrared sensor CO2 control, and microprocessor PID control.
Price is per unit.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Sanyo MCO-20AIC CO2 Incubator includes:
- > UV Lamp
- > 3 Shelves
- > Drain Tray
- > Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Sanyo MCO-20AIC CO2 Incubator Specifications
Temperature Range
|
Ambient +5°C to 50°C
|
Temperature Distribution
|
± 0.25°C
|
Temperature Variation
|
± 0.1°C
|
CO2 Range
|
0 to 20 %
|
CO2 Variation
|
± 0.15 %
|
Chamber Humidity
|
95 % R.H. 5 % R.H.
|
Noise Level
|
30 dB (A scale)
|
Electrical Requirements
|
110-120V, 60Hz, 3.7A, 380W
|
Sanyo MCO-20AIC CO2 Incubator ManualClick Here to View the Technical Specs for the MCO-20AIC
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, CO₂, and H₂O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate CO₂ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and CO₂ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dim, flickering, or dead pixels; replace for readability
|
Completed
|
|
Examine external regulators for damage or malfunction; replace compromised parts
|
Completed
|
|
Inspect temperature, CO₂, and H₂O sensors for correct function and accuracy
|
Completed
|
|
Inspect internal wiring for frays, tears, or breakages; replace compromised wires
|
Completed
|
|
Verify software settings align with components and calibration specs; adjust if needed
|
Completed
|
|
Clean fan and remove dust/obstructions; replace if performance is substandard
|
Completed
|
|
Examine wheels and leveling mounts for structural integrity and balance
|
Completed
|
|
Inspect door gaskets and latches for wear or damage; replace to maintain seal
|
Completed
|
|
Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy
|
Completed
|
|
Calibrate CO₂ level to 5% with Fyrite test kit for atmospheric precision
|
Completed
|
|
Monitor temperature and CO₂ stability over 24-hour period to verify consistency
|
Completed
|
|
Conduct cosmetic inspection to confirm quality of external surfaces and components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|