Benchmark ST-45 CO2 Incubator, 45L, 115V w/ Two Shelves
- Temperature Range Ambient +5°C to 60°C
- Includes Two Shelves
- Brand New
- 2 Year Manufacturer's Warranty
Go to Product Details
Sanyo MCO-19AIC(UV) CO2 Incubator
Temperature Range Ambient +5°C to 50°C
- Advanced humidity and temperature control technology for precise culture conditions
- Direct heat and air jacket system eliminates the need for water and provides even heat distribution
- Dual detector infrared CO2 sensor maintains constant conditions regardless of humidity or temperature changes
- Safe Cell UV contamination control system ensures a sterile environment
- Spacious interior with 170 L volume and four stainless steel trays
- Rigid polyurethane foamed-in-place insulation for efficient temperature control
- PID control system for temperature and CO2 levels with digital displays
- Air circulation with fan assistance for uniform conditions
The Sanyo MCO-19AIC(UV) CO2 Incubator features unprecedented
humidity and temperature control technology, which provides both flexible and
robust stability control for cultures. The new direct heat and air jacket system
eliminates the inconvenient use of water in the incubator and provides heat
from the door, side, and bottom of the unit. The Sanyo MCO-19AIC utilizes a dual detector infrared CO2 sensor, which is not affected by changes in humidity or
temperature, maintains constant conditions via the microprocessor control, and
automatically calibrates using room air temperature as reference. Also features Safe Cell UV contamination control system.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Sanyo MCO-19AIC(UV) CO2 Incubator includes:
- > 2 Shelves
- > Humidity Pan
- > Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Sanyo MCO-19AIC(UV) CO2 Incubator Specifications
External dimensions
|
620 x 710 x 900 mm (W x D x H)
|
Internal dimensions
|
490 x 523x 665 mm (W x D x H)
|
Interior volume
|
170 L
|
Access port
|
Inner diameter: 30 mm, On the back side
|
Trays
|
4 trays made of stainless steel containing copper
450 x 450 x 12 mm (W x D x H), Maximum load: 7 kg/tray
|
Insulation
|
Rigid polyurethane foamed-in place
|
Heating system
|
DHA system (heater jacket + air jacket system)
|
Heater
|
314 W
|
Humidifying system
|
Natural evaporation with humidifying pan
|
Temperature controller
|
PID control system
|
Temperature display
|
Digital display
|
CO2 controller
|
PID control system
|
CO2 density display
|
Digital display
|
Air circulation
|
Fan assisted
|
Temperature control range
|
+5°C above ambient to 50°C (in a 5°C to 35°C ambient).
|
Temperature control uniformity
|
± 0.25°C in 25°C ambient, setting 37°C, 5% CO2, no load.
|
C02 control range and deviation
|
0% to 20%, ± 0.15% in 25°C ambient, setting 37°C, 5% CO2, no load.
|
C02 sensor platform
|
Ceramic based, single beam Infrared sensor, with dual wavelength
measurement for continuous auto-zero calibration
|
Air filter
|
0.3 Pm, Efficiency: 99.97% or higher
|
UV lamp
|
4W X 1 (ozone-free emission)
|
Water level sensor
|
Optical
|
Alarms
|
Automatic set temperature alarm, Automatic set CO2 density alarm,
Upper limit temperature alarm, Door alarm, Low humidifying water
alarm,
UV lamp failure alarm (for UV equipped model only)
|
Remote alarm contacts
|
Allowable contact capacity: 30 VDC, 2 A
|
CO2 inlet connection
|
4 to 6 mm diameter tube
|
CO2 inlet pressure
|
0.03 MPaG (0.3 kgf/cm2 G, 4.3 psiG)
|
Weight
|
93 kg
|
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, CO₂, and H₂O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate CO₂ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and CO₂ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dim, flickering, or dead pixels; replace for readability
|
Completed
|
|
Examine external regulators for damage or malfunction; replace compromised parts
|
Completed
|
|
Inspect temperature, CO₂, and H₂O sensors for correct function and accuracy
|
Completed
|
|
Inspect internal wiring for frays, tears, or breakages; replace compromised wires
|
Completed
|
|
Verify software settings align with components and calibration specs; adjust if needed
|
Completed
|
|
Clean fan and remove dust/obstructions; replace if performance is substandard
|
Completed
|
|
Examine wheels and leveling mounts for structural integrity and balance
|
Completed
|
|
Inspect door gaskets and latches for wear or damage; replace to maintain seal
|
Completed
|
|
Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy
|
Completed
|
|
Calibrate CO₂ level to 5% with Fyrite test kit for atmospheric precision
|
Completed
|
|
Monitor temperature and CO₂ stability over 24-hour period to verify consistency
|
Completed
|
|
Conduct cosmetic inspection to confirm quality of external surfaces and components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|