Ohaus Frontier FC5306 Mini Centrifuge
The Ohaus Frontier FC5306 Mini Centrifuge is an efficient tool designed for rapid and simple separation. This compact centrifuge features an 8-position rotor for 1.5/2.0 ml tubes. One of its key features is the tool-free, quick-release design, which allows for effortless installation and removal of rotors. It operates quietly and safely, making it ideal for everyday laboratory use. Another key feature is the quiet motor paired with a vibration-absorbing rubber base, ensuring minimal noise disruption. Safety is paramount with the Frontier FC5306, as it is equipped with multiple safety features such as a sturdy lid, safety switches that halt rotor operation if the lid opens, and an imbalance sensor that prevents operation under imbalanced conditions. This centrifuge stands out for its simplicity, and it begins rotation automatically upon lid closure, requiring no additional button presses, thus streamlining the sample separation process.
The included rotor reaches a maximum speed of 6,000 RPM. All of our equipment is in excellent condition and will be fully tested to perform at factory specifications before being shipped.
Please confirm this rotor meets your application needs and request a different rotor, if necessary. Available rotors can be found in our
Rotor Compatibility Guide.
The Ohaus Frontier FC5306 Mini Centrifuge includes:
- > 8 x 1.5/2.0 ml Fixed Angle Rotor
- > NIST Centrifuge Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Ohaus Frontier FC5306 Mini Centrifuge Specifications
Maximum Speed
|
6,000 RPM
|
Maximum RCF
|
2,000 x g
|
Maximum Capacity
|
8 x 1.5/2.0 ml
|
Temperature Range
|
N/A
|
Timer
|
N/A
|
Acceleration Time
|
≤ 2 seconds
|
Deceleration Time
|
≤ 3 seconds
|
Drive Mode and Motor
|
Direct drive, with low noise attributable to rolling bearing
|
Dimensions (W x D x H)
|
5.9 x 6.6 x 5 in. (15 x 16.8 x 12.8 cm)
|
Weight
|
2.3 lb. (1,1 kg)
|
Electrical Requirements
|
100-240V, 50/60Hz, 1.5A
|
Refrigeration
|
No Refrigeration
|
- Door Latch Assembly Checked for Full Function
- Door Hinges are Checked and Lubed as Needed
- Drive Belt is Checked for Rips and Tears and Replaced if Needed
- Rotors and O-rings are Lubed as Needed
- Lamps and Display are Checked and Replaced if Dim
- Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
- Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly