Popular Alternative Choice
Arctiko ULUF 450 -86°C Ultra Low Upright Freezer
- Arctiko ULUF 450: -40°C to -86°C, 13.9 cu. ft. volume.
- Single compressor tech: efficient, quiet operation.
- Direct cooling & evaporator coils for uniformity.
- Filter-less design & heated door frame benefits.
Go to Product Details
Brand New with Manufacturer's Warranty!
New Brunswick Innova U101 -86C Freezer
The New Brunswick Innova U101 -86C Freezer has an overall
capacity of 3.6 cubic feet and an ultimate low temperature of -86C, making the
U101 spacious and cold enough for a range of laboratory freezing
applications. The
onboard digital display allows the user to enter a variety of information, including
and not limited to: temperature set point, low alarm, high alarm, lock, current
temperature, and more. Along with a digital display, the U101 offers extremely intuitive
user controls with simple and easy to read button controls. Compared to ULT
Freezers, the Innova U101 -86C Freezer can reach the same low temperatures
with reduced amount of power consumption in the process.
The Innova U101 features vacuum insulation panels, gasketed inner doors for minimal cold air loss, an easy-to-read LED panel, SMART PLUS diagnostic system, easy inner door removal, full stainless steel interior, password protection of alarms and setpoints, reduced noise levels, and a temperature range of -50 to -86C.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The New Brunswick Innova U101 -86C Freezer includes:
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
New Brunswick Innova U101 -86C Freezer Specifications
Capacity
|
3.6 cubic feet
|
Alarms
|
High/Low temperature, battery low, power fail, fault, filter clean
|
Interior
|
Stainless steel grade 304L
|
Performance
|
-50 C to -86 C at 32 C maximum ambient operating temperature
|
Pull down time from +25C to -86C
|
3.2 hours
|
Control
|
Digital
|
New Brunswick Innova U101 Manual
Click Here to View all the Technical Specs for the Innova U101
- Inspect the display for pixel clarity and brightness, replacing any dim or dead pixels.
- Test all buttons for responsiveness, resistance, and durability; replace any that don’t meet standards.
- Check the door seal and lock for airtightness, replacing any compromised components.
- Run diagnostics on PCB test points for voltage and current accuracy, replacing faulty components.
- Verify compressor output and airflow, ensuring all internal fans function properly.
- Cross-check internal temperature probe accuracy with a NIST-traceable probe, recalibrating if needed.
- Inspect wiring for frays or tears, replacing compromised sections as necessary.
- Test the start capacitor's capacitance and replace if it’s outside the specified range.
- Replace all internal filters and thoroughly clean condenser fins for efficient heat dissipation.
- Verify the alarm battery holds a full charge and replace if there is any degradation.
- Operate the unit for 72 hours to confirm stable temperatures and operational consistency.
- Perform a final cosmetic check, repairing or touching up surfaces as needed for a professional appearance.
Technician Inspection and Recertification Checklist
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task |
Completed? |
Remarks? |
Inspect display for pixel issues and replace if needed | Completed | |
Test button functionality and replace any defective buttons | Completed | |
Examine door seal and lock functionality; replace if compromised | Completed | |
Conduct PCB test point diagnostics and replace as needed | Completed | |
Verify compressor and internal fan functionality | Completed | |
Confirm temperature probe accuracy with NIST-traceable probe | Completed | |
Inspect all wiring for frays, tears, or breakages | Completed | |
Test start capacitor capacitance range; replace if needed | Completed | |
Replace all internal filters and clean condenser fins | Completed | |
Test alarm battery for full functionality | Completed | |
Run 72-hour test with data recorder to confirm stable temperatures | Completed | |
Conduct cosmetic inspection and address any issues | Completed | |
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|