Mettler Toledo AB135-S/FACT Analytical Balance
The Mettler Toledo AB135-S/FACT Analytical Balance is ideal for piece counting, percent weighing, dynamic weighing, or free factor use. Weight output can be read as g, kg, mg, carat, lbs, oz, GN, dwt, mo, etc. All of our equipment is fully tested to perform at factory specifications before being shipped.
The Mettler Toledo AB135-S/FACT Analytical Balance includes:
- > Calibration Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Mettler Toledo AB135-S/FACT Analytical Balance Specifications
Max. Capacity
|
31 g / 120 g
|
Readability
|
0.01 mg / 0.1
mg
|
Repeatability
(sd)
|
0.03 mg / 0.1 mg
|
Linearity
|
0.2mg
|
Calibration
Type
|
Internal
|
RS-232
|
Yes
|
Stabilization
Time
|
4 s / 15 seconds
|
Electrical Requirements
|
8-14.5 VAC, 50/60Hz,
6VA, 6W
|
Mettler Toledo AB135-S/FACT Manual
Click Here to View all the Technical Specs for the AB 135-S/FACT
- Verify power supply output for precise voltage delivery in accordance with equipment specifications
- Assess full functionality of display and control buttons, replacing any defective or deteriorating components as necessary
- Confirm balance is properly leveled to ensure measurement accuracy and stability
- Examine windscreen glass for cracks or chips, replacing if structural integrity is compromised
- Inspect all internal wiring and electrical connections for secure attachment and check for any loose connections or damaged connectors
- Check power cord integrity, ensuring there are no frays, cuts, or damage affecting function or safety
- Execute internal or external calibration to confirm accuracy of weighing measurements
- Review cosmetic condition, confirming no visible damage or wear that affects functionality
- Verify successful taring of the weighing pan to zero out prior measurements accurately
- Ensure RS232/printer communication functions correctly, validating connection and data transmission (if applicable)
Technician Inspection and Recertification Checklist: Balances
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify power supply output voltage
|
Completed
|
|
Assess display and control button functionality, replacing faulty components
|
Completed
|
|
Confirm balance leveling for measurement accuracy
|
Completed
|
|
Inspect windscreen glass for cracks, replace if necessary
|
Completed
|
|
Check internal wiring and electrical connections for security
|
Completed
|
|
Inspect power cord for frays or damage
|
Completed
|
|
Execute internal/external calibration for measurement accuracy
|
Completed
|
|
Review cosmetic condition for visible damage
|
Completed
|
|
Verify weighing pan tares successfully
|
Completed
|
|
Ensure RS232/printer communication is functional (if applicable)
|
Completed
|
|