Home > Centrifuges >

Labnet Hermle Z206A BenchTop Centrifuge
Labnet Hermle Z206A BenchTop Centrifuge
 
 



Our Price: $2,385.00

Condition: Fully Recertified and Tested to Perform at Manufacturer Specifications
Warranty: 180-Day Full Parts and Labor (Click for Info)
Typically Ships Within: 1 to 2 Business Days
Included Documentation: NIST Centrifuge Calibration and Preventative Maintenance Report

Request a Formal Quote


Quantity in Stock:1

Free Shipping
Product Code: LHZ206A
Qty:

Description
Recertification Protocol
Technical Specification Sheet
 

Popular Alternative Choice

Ohaus FC5706 Frontier Multi Centrifuge w/ 6 x 50ml Fixed Angle Rotor

  • Ohaus FC5706 Frontier Multi Centrifuge with 6 x 50ml Fixed Angle Rotor: Versatile Benchtop Solution for Precise Separation.
  • Offers intuitive operation with an easy-to-use interface.
  • Speed range: 200 to 6,000 RPM (included rotor).
  • Max capacity: 6 x 50ml tubes; 2-year warranty.
Go to Product Details

Brand New!

Labnet Hermle Z206A BenchTop Centrifuge


The Labnet Hermle Z206A is a compact benchtop centrifuge ideal for use in research and clinical laboratories. The Z206A features nine braking and acceleration levels, along with an imbalance sensor. Speed can be both set and viewed in RPM, RCF, or both. Maximum speeds up to 6,000 RPM with a maximum RCF of 4,285 x g. Accommodates up to 6 x 50ml capacity with rotors available.

This centrifuge is in excellent condition and will be fully tested to perform at factory specifications before being shipped.

INCLUDED:
The Labnet Hermle Z206A BenchTop Centrifuge includes:
  • > Hermle 220.97, 6 x 50ml Rotor
  • > NIST Centrifuge Calibration and Preventative Maintenance Report
  • > Power Cord
  • > Operator's Manual
  • > Full 180 Day Parts and Labor Warranty

Labnet Hermle Z206A Benchtop Centrifuge Specifications

Max Speed

6000 rpm

Max Volume

6 x 50 ml

Max RCF

4185 x g

Admissible Density

1.2 kg/dm 3

Admissible Kinetic Energy

1694 Nm

Dimensions (W x D x H)

28 x 37 x 26 cm

Refrigeration No Refrigeration


Preventative Maintenance Performed on The Labnet Hermle Z206A BenchTop Centrifuge

  • Door Latch Assembly Checked for Full Function
  • Door Hinges are Checked and Lubed as Needed
  • Drive Belt is Checked for Rips and Tears and Replaced if Needed
  • Rotors and O-rings are Lubed as Needed
  • Lamps and Display are Checked and Replaced if Dim
  • Line Cord is Checked for Signs of Fray or Damage and Replaced Accordingly
  • Internal Circuitry is Checked for Faulty/Shorted Components and Replaced Accordingly


Labnet Hermle Z206A Centrifuge Manual
Click Here to View all the Technical Specs for the Z206A Centrifuge


Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item:

Centrifuges
Brand
Brand > Labnet
Centrifuge RCF > Less than 10,000 x g
Centrifuge RCF