Invitrogen PowerEase 500 Electrophoresis Power Supply
- Tailored for optimal performance in gel electrophoresis applications.
- Includes eight, pre-set and four, customizable methods.
- User-friendly interface allows for easier operation.
- Features constant voltage, current, or power settings, and buffer temperature monitoring.
- On-The-Fly Program Editing allows for adjustments during use.
The Invitrogen PowerEase 500 Electrophoresis Power Supply is designed specifically for mini-gel electrophoresis. It offers extensive programming capabilities, including eight pre-set and four custom methods for you to set to your own preferences. The simple, intuitive PowerEase interface is faster and easier to use than traditional "dial-in" power supplies. In addition, PowerEase features: constant voltage, current, or power settings; buffer temperature monitoring capability; "on the fly" program editing; and compatibility with most printers using a parallel port.
All of our equipment is tested to perform at factory specifications before being shipped.
The Invitrogen PowerEase 500 Electrophoresis Power Supply includes:
- > Power Cord
- > Operator's Guide
- > Full 180 Day Parts and Labor Warranty
Invitrogen PowerEase 500 Electrophoresis Power Supply Specifications
Input power
|
100/120 VAC
|
90-132V, 50/60 Hz, 100 watts at maximum load
|
Fuse
|
One 1A/250V/AGC, fast blow fuse
|
220/240 VAC
|
198-264VAC, 50/60 Hz, 260 mA at maximum load
|
Fuses
|
Two F1A/250V/5x20 mm fast blow fuses
|
Power
|
Max Voltage: 500V
|
Max Current: 500mA
|
Max Wattage: 50W
|
Accuracy
|
Voltage: 2% or 2 volts
Current: 2% or 2 mA
Wattage 2% or 0.2 watt
|
Drift
|
< 1% in 8 hours after 30 minute warm-up with constant supply
voltage
|
Circuit Protection
|
Open Circuit; Short Circuit; Thermal Protection Over Voltage,
Current, Wattage
|
Safety
|
Load Detection
Thermal Shutoff (with optional temperature probe)
Isolated Floating Ground
|
Display
|
LCD
|
Invitrogen PowerEase 500 Manual
Click Here to View all the Technical Specs for the Novex PowerEase 500
- Verify internal power supply output for correct voltage in alignment with equipment specifications
- Inspect LED display for any dim or dead pixels, ensuring optimal readability
- Examine internal wiring and connections, checking for any rips, tears, or compromised insulation
- Ensure fan is clean and fully operational to maintain adequate cooling
- Test PCB test points for proper voltage output, confirming consistent circuit performance
- Validate functionality of all buttons and switches, ensuring responsive control
- Measure and confirm constant voltage, amplitude, and wattage using precise resistance values
- Cross-check displayed voltage with multimeter readings for accuracy
- Monitor for rapid resistance changes, software errors, and power fluctuations
- Inspect line cord for any signs of wear, cuts, or damage impacting safety
- Confirm cosmetic condition meets quality standards, free of any damage affecting functionality or aesthetics
Technician Inspection and Recertification Checklist: Electrophoresis Power Supplies
The Following Checklist Is to Be Performed on All Incoming and Outgoing Equipment
Task
|
Completed?
|
Remarks?
|
Verify internal power supply output voltage
|
Completed
|
|
Inspect LED display for dim or dead pixels
|
Completed
|
|
Examine internal wiring for rips or tears
|
Completed
|
|
Ensure fan is clean and fully operational
|
Completed
|
|
Test PCB test points for voltage accuracy
|
Completed
|
|
Validate functionality of buttons and switches
|
Completed
|
|
Confirm constant voltage, amplitude, and wattage with resistance
|
Completed
|
|
Cross-check displayed voltage with multimeter
|
Completed
|
|
Monitor for rapid resistance changes and power fluctuations
|
Completed
|
|
Inspect line cord for wear or damage
|
Completed
|
|
Confirm cosmetic condition meets quality standards
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|