Agilent HP G1600AX 3D Capillary Electrophoresis
The HP G1600AX 3D Capillary Electrophoresis system includes a computer equipped with necessary software. Capillary electrophoresis (CE), with its high efficiency and resolution, rapid analysis time, plus minimal sample and solvent requirements, covers a broad range of applications in a wide variety of industries. Agilent Technologies developed this technique with the Agilent Capillary Electrophoresis system. Innovations include diode array detection in CE, the extended light-path capillaries, automated fraction collection, capillary electrochromatography (CEC), the high sensitivity detection cell, and fully integrated solutions for CE/MS. HPLC-like reproducibility, sensitivity and linearity integrated software with graphical user interface pioneering new separation techniques, including capillary electrochromatography (CEC) and capillary electrophoresis mass spectrometry (CE/MS) extensive regulatory compliance tools.
All of our equipment is fully tested to perform at factory specifications before being shipped.
Included with the Agilent HP G1600AX 3D Capillary Electrophoresis:
Includes:
> DataStation with software
> Calibration Report
> Operator's Guide
> Power Cord
> Full 180 Day Parts and Labor Warranty
Agilent HP G1600AX 3D Capillary Electrophoresis Specifications
Detector
|
UV/Vis diode-array detector (190-600nm)
|
Wavelength accuracy
|
± 1 nm
|
Response time
|
0.1 - 10 seconds (8 choices)
|
Light source
|
Deuterium lamp
|
Pressure system
|
Programmable with 0-50 mbar bidirectional flushing with 1
bar or with high pressure 2-12 bar bidirectional, vial pressurization with
high pressure 2 -12 bar
|
Capillary cassette
|
Forced-air-temperature-controlled with Peltier element
Temp. Range: 10°C below ambient - 60°V
(±0.1°C) with a min. of 4°C
|
Vials
|
1001l sample vials, 1mL or 2mL buffer vials (polypropylene
or glass) with resealing snap caps
|
Injection modes
|
Self correcting injection system with injection from both
ends.
Programmable range: up to 10,000 sec.
Pressure: 0 - 50 mbar
Electrokinetic: 0 - 30 kV
|
Operating environment
|
Temperature: 5 - 40°C
Humidity: up to 80%, at 30°C (n.c.)
|
Electrophoresis power
|
Voltage range: 0 to ± 30 kV supply
Current: setable: 0 - 300µA
Power: setable: 0 - 6 W
operating under constant voltage, current or power programmable polarity
switch
|
Autosampler/ Fraction collection
|
48 - position carousel. All vials are randomly
accessible from cathode and anode end of capillary. Temperature control
with external waterbath with vial temp. from 10 - 40°C (n.c.)
|
Power requirements
|
100-120/220-240 VAC 50/60Hz
|
Dimensions
|
20.5" (D) x 16.8" (W) x 22.7" (H)
Weight = 115lbs
|
Agilent CE G1600AX Capillary Electrophoresis System