Heraeus Heracell 240 CO2 Incubator
The Heraeus HERAcell 240 CO2 incubator is ideal for cell and
tissue cultures, including development of ova or embryos at or near body
temperature. The HERAcell 240 uses a new type of water reservoir, which
provides a humidity recovery time up to five times faster than common CO2
incubators with water trays. Expect consistent culture conditions in this
incubator due to the air jacket temperature control and upper-temperature limit
protection feature. The HERAcell is designed with fewer contamination-prone
surfaces, ensuring the protection of cultures, and features the exclusive
automated ContraCon decontamination procedure using moist heat at 90°C.
All of our equipment is fully tested to perform at factory
specifications before being shipped.
The Heraeus Heracell 240 CO2 Incubator includes:
- > 2 Shelves
- > Calibration and Preventative Maintenance Report
- > Power Cord
- > Operator's Manual
- > Full 180 Day Parts and Labor Warranty
Heraeus Heracell 240 CO2 Incubator Specifications
External Dimensions (W x H x D)
|
30.7 x 36.8 x 32.8 in
|
Internal Dimensions (W x H x D)
|
23.9 x 26.4 x 23.0 in
|
Total Volume
|
approx. 238 L (8.4 cu. ft.)
|
Temperature Control Range
|
TA +3° to 55°C
|
Temperature Deviation, Time/Spatial
|
±0.1°C / ±0.5°C
|
Ambient Temperature Range
|
+18° to 33°C
|
Recovery Time at 37°C
|
≤ 10 minutes
|
Constant Humidity
|
≥ 95%rH
|
Recovery time, 5% CO2
|
≤ 10 minutes
|
O2 Control Accuracy
|
Vol ± 0.1%
|
Rated Voltage
|
115V
|
Rated Output
|
0.61kW (0.64kW)
|
Rated Frequency
|
50Hz/60Hz
|
Heracell 240 CO2 Incubator Manual
Click Here to View all the Technical Specs for the Heracell 240
- Inspect the display for any dim, flickering, or dead pixels, replacing any affected areas to maintain full readability and operational clarity
- Thoroughly examine external regulators for any signs of damage, wear, or malfunction (if applicable), replacing any compromised parts
- Inspect temperature, CO₂, and H₂O sensors (if applicable), ensuring each sensor is functioning correctly and accurately reporting conditions
- Conduct a detailed inspection of all internal wiring for frays, tears, or breakages; replace any compromised wires to ensure safe and reliable connections
- Verify that software settings align with the internal components and calibration specifications, adjusting configurations as needed for accurate operation
- Inspect and clean the fan, ensuring it is free from dust or obstructions; replace if performance is below required standards
- Examine wheels and leveling mounts for structural integrity, ensuring proper balance and stability for safe operation
- Inspect door gaskets and latches for any signs of wear or damage, replacing if necessary to maintain a secure seal and optimal environmental control
- Calibrate temperature accuracy at 37°C using a NIST-traceable probe, confirming it meets required tolerances
- Calibrate CO₂ level to 5% using a Fyrite combustion test kit (if applicable), ensuring precise atmospheric conditions
- Monitor temperature and CO₂ stability over a 24-hour period, verifying consistent operation within specified ranges
- Conduct a thorough cosmetic inspection to confirm all external surfaces and components meet quality standards, free from visible damage or wear
Technician Inspection and Recertification Checklist: Incubator
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Inspect display for dim, flickering, or dead pixels; replace for readability
|
Completed
|
|
Examine external regulators for damage or malfunction; replace compromised parts
|
Completed
|
|
Inspect temperature, CO₂, and H₂O sensors for correct function and accuracy
|
Completed
|
|
Inspect internal wiring for frays, tears, or breakages; replace compromised wires
|
Completed
|
|
Verify software settings align with components and calibration specs; adjust if needed
|
Completed
|
|
Clean fan and remove dust/obstructions; replace if performance is substandard
|
Completed
|
|
Examine wheels and leveling mounts for structural integrity and balance
|
Completed
|
|
Inspect door gaskets and latches for wear or damage; replace to maintain seal
|
Completed
|
|
Calibrate temperature at 37°C with NIST-traceable probe to confirm accuracy
|
Completed
|
|
Calibrate CO₂ level to 5% with Fyrite test kit for atmospheric precision
|
Completed
|
|
Monitor temperature and CO₂ stability over 24-hour period to verify consistency
|
Completed
|
|
Conduct cosmetic inspection to confirm quality of external surfaces and components
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|