Popular Alternative Choice
Polyscience WBE20A11B 20L Digital Water Bath (Ambient +5 to 99C), 120V, 60Hz
- 20L Capacity: Polyscience WBE20A11B Digital Water Bath.
- Optimum Uniformity: Features PID microprocessor control.
- Key Features: Calibration, stainless steel reservoir, safety thermostats.
- Technical Specs: ±0.1°C stability, 120V/60Hz, ETL approved.
Go to Product Details
Free Shipping!
Fisher Scientific Isotemp 215 Digital Water Bath
Temperature Range
Ambient to 100°C
Temperature Uniformity
±0.24°C at 37°C
- Microprocessor control ensures precise temperature management.
- Equipped with unique “fins” for safer, easier opening and protection from hot vapors.
- The cover can stay open at a 90° position or be completely removed for accommodating large glassware.
- Cool-touch plastic rim stays cool even when operating at maximum temperature, enhancing user safety.
- Power-on self-test automatically checks vital circuitry upon turning on the unit, with warning messages for detected issues.
- Calibration adjustment allows for front panel accessed calibration to optimize accuracy for commonly used temperatures.
- Dual thermostats for controlling the set point temperature as well as monitoring the overall product for overheating.
The Fisher Scientific Isotemp 215 Dual Water Bath features a microprocessor controlled water bath with a digital control/readout, volume 10 L and 5L, temperature up to 99.9°C, temperature uniformity 0.24°C at 37°C, stability 0.5°C at 37°C, 120 V. All of our equipment will be fully tested to perform at factory specifications before being shipped.
The Fisher Scientific Isotemp Dual Digital 215 Water Bath includes:
- > Lids
- > Operator's Manual
- > Power Cord
- > Full 180 Day Parts and Labor Warranty
Fisher Scientific Isotemp Digital 215 Water Bath Specifications
Temperature Range |
Ambient to 100°C |
Temperature Uniformity |
±0.24°C at 37°C |
Control |
Digital |
Capacity |
5L and 10L (1.3 gal and 2.6 gal) |
Bath Dimensions (L x W x H) |
5L Bath: 6.1 x 11.8 x 5.9 in (15.4 x 30 x 15 cm)
10L Bath: 11.9 x 13 x 5.9 in (30.1 x 33 x 15 cm) |
Electrical Requirements |
120V |
Temperature Stability |
±0.5°C at 37°C |
Fisher Isotemp 215 Manual Click Here to View all the Technical Specs for the Isotemp 215
- Confirm power supply and PCB are outputting stable, correct voltages across all essential circuits to ensure reliable operation
- Inspect the display for any dim, flickering, or dead pixels, replacing any compromised sections to maintain full clarity and accurate readouts
- Verify that all buttons, knobs, and switches are functioning properly, providing precise and responsive control across all settings
- Conduct a thorough inspection of the water reservoir for any holes, rust, or other structural damage that may impact its integrity
- Fill the reservoir with water, checking closely for any external or internal leaks that could affect performance
- Examine the lid for any signs of wear or damage, replacing hinges and handles if necessary to ensure a secure and proper seal
- Inspect for any internal leaks originating from the water reservoir, confirming the unit’s internal plumbing integrity
- Conduct a comprehensive inspection of internal wiring for any breakages, tears, or wear; replace any underperforming or damaged components to maintain safe operation
- Examine internal insulation for signs of burns, breaks, or deterioration, replacing as needed to ensure thermal efficiency and safety
- Confirm that all feet are intact and that the bath sits level and balanced on a flat surface to prevent movement or instability
- Calibrate both temperature accuracy and uniformity using a NIST-traceable temperature probe, verifying compliance with specification standards
- Perform a detailed cosmetic inspection to confirm that all external surfaces and finishes meet aesthetic and quality standards
Technician Inspection and Recertification Checklist: Water Bath
The Following Checklist Is to Be Performed on All Incoming and Outgoing Pieces of Equipment
Task
|
Completed?
|
Remarks?
|
Confirm power supply and PCB output stable, correct voltages across circuits
|
Completed
|
|
Inspect display for dim, flickering, or dead pixels; replace for clarity
|
Completed
|
|
Verify functionality of all buttons, knobs, and switches for responsive control
|
Completed
|
|
Inspect water reservoir for holes, rust, or structural damage
|
Completed
|
|
Fill reservoir with water; check for external or internal leaks
|
Completed
|
|
Examine lid for wear or damage; replace hinges or handles as needed
|
Completed
|
|
Inspect for internal leaks from water reservoir to confirm plumbing integrity
|
Completed
|
|
Check internal wiring for damage; replace underperforming components for safety
|
Completed
|
|
Examine internal insulation for burns, breaks, or deterioration; replace as needed
|
Completed
|
|
Confirm feet are intact and bath is balanced on flat surface
|
Completed
|
|
Calibrate temperature accuracy and uniformity with NIST-traceable probe
|
Completed
|
|
Perform cosmetic inspection to confirm quality of external surfaces and finishes
|
Completed
|
|
To View More of Our Recertification Protocol Click Here
|
|
|
|
|
|
|